Nester Christopher

Dr. Nester Christopher

School of Health & Society, University of Salford, Salford M5 4WT, UK

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in Journal of Biomechanics
Verified
Journal Article
Closed access
NCNester Christopher
Nester Christopher
RJRichard Jones
Richard Jones
ALA. Liu
A. Liu
DHD. Howard
D. Howard
ALA. Lundberg
A. Lundberg
PWP. Wolf
P. Wolf

1 April 2003 in Gait & Posture
Verified
Journal Article
Closed access
NCNester Christopher
Nester Christopher
MLM.L van der Linden
M.L van der Linden
PBP Bowker
P Bowker

1 January 2007 in Journal of Biomechanics
Verified
Journal Article
Closed access
NCNester Christopher
Nester Christopher
ALA.M. Liu
A.M. Liu
EWE. Ward
E. Ward
DHD. Howard
D. Howard
JCJ. Cocheba
J. Cocheba
PPP. Patterson
P. Patterson

1 January 2013 in Journal of Foot and Ankle Research
Verified
Journal Article
Open access
PDF file
KMKaren J. Mickle
Karen J. Mickle
NCNester Christopher
Nester Christopher
GCGillian Crofts
Gillian Crofts
JSJulie Steele
Julie Steele
Background: Measuring the strength of individual foot muscles is very challenging; however, measuring muscle morphology has been shown to be associated with strength. A reliable method of assessing foot muscle atrophy and hypertrophy would therefore be beneficial to researchers and clinicians. Thus, the aim of this study was to evaluate the test‐retest intra‐observer reliability of ultrasound to measure the morphology of the primary toe flexor muscles.Method: The abductor hallucis, flexor hallucis brevis, flexor digitorum brevis, quadratus plantae and abductor digiti minimi muscles in the foot, and the flexor digitorum longus and flexor hallucis longus muscles in the shank were assessed in five males and five females (mean age = 32.1 ± 10.1 years). Muscles were imaged using a GE Venue 40 ultrasound (6‐9 or 7.6‐10.7 MHz transducer) in a random order, and on two occasions 1‐6 days apart. Muscle thickness and cross‐sectional area were measured using Image J software with the assessor blinded to muscle and day of scan. Intraclass correlation coefficients (ICC) and limits of agreement were calculated to assess day‐to‐day repeatability of the measurements.Results: The method was found to have good reliability (ICC = 0.89‐0.99) with limits of agreement between 8‐28% of the relative muscle size.Conclusion: The protocol described in this paper showed that ultrasound is a reliable method to measure morphology of the toe flexor muscles. The portability and advantages of ultrasound make it a useful tool for clinical and research settings.

1 November 2007 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
AWAnita E Williams
Anita E Williams
NCNester Christopher
Nester Christopher
MRMichael I Ravey
Michael I Ravey
Specialist 'therapeutic' footwear is recommended for patients with diseases such as rheumatoid arthritis (RA) as a beneficial intervention for reducing foot pain, improving foot health, and increasing general mobility. However, many patients choose not to wear this footwear. Recommendations from previous studies have been implemented but have had little impact in improving this situation. The aim of this study was to explore RA patients' experiences of this footwear to ascertain the factors which influence their choice to wear it or not.

15 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JTJinghua Tang
Jinghua Tang
DBDan L. Bader
Dan L. Bader
DMDavid Moser
David Moser
DPDaniel J. Parker
Daniel J. Parker
SFSaeed Forghany
Saeed Forghany
LJLiudi Jiang
Liudi Jiang
Pressure coupled with shear stresses are the critical external factors for diabetic foot ulceration assessment and prevention. To date, a wearable system capable of measuring in-shoe multi-directional stresses for out-of-lab analysis has been elusive. The lack of an insole system capable of measuring plantar pressure and shear hinders the development of an effective foot ulcer prevention solution that could be potentially used in a daily living environment. This study reports the development of a first-of-its-kind sensorised insole system and its evaluation in laboratory settings and on human participants, indicating its potential as a wearable technology to be used in real-world applications. Laboratory evaluation revealed that the linearity error and accuracy error of the sensorised insole system were up to 3% and 5%, respectively. When evaluated on a healthy participant, change in footwear resulted in approximately 20%, 75% and 82% change in pressure, medial–lateral and anterior–posterior shear stress, respectively. When evaluated on diabetic participants, no notable difference in peak plantar pressure, as a result of wearing the sensorised insole, was measured. The preliminary results showed that the performance of the sensorised insole system is comparable to previously reported research devices. The system has adequate sensitivity to assist footwear assessment relevant to foot ulcer prevention and is safe to use for people with diabetes. The reported insole system presents the potential to help assess diabetic foot ulceration risk in a daily living environment underpinned by wearable pressure and shear sensing technologies.