Zhe Li

Dr. Zhe Li


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LZLiying Zhu
Liying Zhu
WLWu Lu
Wu Lu
MSManuchehr Soleimani
Manuchehr Soleimani
ZLZhe Li
Zhe Li
MZMaomao Zhang
Maomao Zhang
In recent years, there has been an increasing interest in applying electrical impedance tomography (EIT) in lung monitoring, due to its advantages of being non-invasive, non-ionizing, real-time, and functional imaging with no harmful side effects. However, the EIT images reconstructed by traditional algorithms suffer from low spatial resolution. This paper proposes a novel EIT-based lung monitoring scheme by using a 3D digital twin lung model and a deep learning-based image reconstruction algorithm. Unlike the static numerical or experimental simulations used in other data-driven EIT imaging methods, our digital twin lung model incorporates the biomechanical and electrical properties of the lung to generate a more realistic and dynamic dataset. Additionally, the image reconstruction neural network (IR-Net) is used to learn the prior information in the dataset and accurately reconstruct the conductivity variation within the lungs during respiration. The results indicate that EIT using a guided digital twin and deep learning-based image reconstruction has better accuracy and anti-noise performance compared to traditional EIT. The proposed EIT imaging framework provides a new idea for efficiently creating labeled EIT data and has potential to be used in various data-driven methods for electrical biomedical imaging.

1 June 2014
Verified
Conference Paper
Closed access
JWJiandong Wu
Jiandong Wu
Li LanLi Lan
Li Lan
ZLZhe Li
Zhe Li
YYYi Yin
Yi Yin
In this paper, an simply ion charge transport model is proposed, compared with bipolar charge transport model. It consists of ion generation by field assisted dissociation of impurities, transport, trapping and recombination in polymer. To simplify the model, it is assumed that only one type of impurity existing in polymer. Space charge behavior is simulated with the modified model. Compared with the experiment and simulation results, space charge behavior simulated with bipolar charge transport model could not fit the experiment to some extent. It may be associated with the limitation of charge source. Introduction of ion charge in bipolar charge transport model could simulate the heterocharge accumulation near electrodes, in accordance with experiment result. It is consider that ion transport may be the dominant mechanism for the heterocharge accumulation.

22 November 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
CSChen Shang
Chen Shang
YYYa Yang
Ya Yang
CHChengcheng He
Chengcheng He
JFJunqi Feng
Junqi Feng
YLYan Li
Yan Li
ZLZhe Li
Zhe Li
Background: The sleep status of patients in the surgical intensive care unit (ICU) significantly impacts their recoveries. However, the effects of surgical procedures on sleep are rarely studied. Objective: This study aimed to investigate quantitatively the impact of traditional open surgery (TOS) versus minimally invasive surgery (MIS) on patients’ first-night sleep status in a surgical ICU. Methods: Patients transferred to the ICU after surgery were prospectively screened. The sleep status on the night of surgery was assessed by the patient- and nurse-completed Richards-Campbell Sleep Questionnaire (RCSQ) and Huawei wearable sleep monitoring wristband. Surgical types and sleep parameters were analyzed. Results: A total of 61 patients were enrolled. Compared to patients in the TOS group, patients in the MIS group had a higher nurse-RCSQ score (mean 60.9, SD 16.9 vs mean 51.2, SD 17.3; P=.03), self-RCSQ score (mean 58.6, SD 16.2 vs mean 49.5, SD 14.8; P=.03), and Huawei sleep score (mean 77.9, SD 4.5 vs mean 68.6, SD 11.1; P<.001). Quantitative sleep analysis of Huawei wearable data showed a longer total sleep period (mean 503.0, SD 91.4 vs mean 437.9, SD 144.0 min; P=.04), longer rapid eye movement sleep period (mean 81.0, 52.1 vs mean 55.8, SD 44.5 min; P=.047), and higher deep sleep continuity score (mean 56.4, SD 7.0 vs mean 47.5, SD 12.1; P=.001) in the MIS group. Conclusions: MIS, compared to TOS, contributed to higher sleep quality for patients in the ICU after surgery.

13 October 2022 in Frontiers in Physiology
Verified
Journal Article
Open access
SQShaojie Qin
Shaojie Qin
YYYulong Yao
Yulong Yao
YXYuqing Xu
Yuqing Xu
DXDanling Xu
Danling Xu
YGYuan Gao
Yuan Gao
ZLZhe Li
Zhe Li
Objective: Electrical impedance tomography (EIT) is a technique to measure electrical properties of tissue. With the progress of modern integrated circuits and microchips, EIT instrumentation becomes an active research area to improve all aspects of device performance. Plenty of studies on EIT hardware have been presented in prestigious journals. This study explores publications on EIT hardware to identify the developing hotspots and trends.Method: Publications covering EIT hardware on the Web of Science Core Collection (WoSCC) database from 1989 to 2021 were collected for bibliometric analysis. CiteSpace and VOS viewer were used to study the characteristics of the publications.Main results: A total of 592 publications were analyzed, showing that the number of annual publications steadily increased. China, England, and South Korea were the most prolific countries on EIT hardware publications with productive native institutions and authors. Research topics spread out in “bio-electrical impedance imaging”, “hardware optimization”, “algorithms” and “clinical applications” (e.g., tissue, lung, brain, and oncology). Hardware research in “pulmonary” and “hemodynamic” applications focused on monitoring and were represented by silhouette recognition and dynamic imaging while research in “tumor and tissue” and “brain” applications focused on diagnosis and were represented by optimization of precision. Electrode development was a research focus through the years. Imaging precision and bioavailability of hardware optimization may be the future trend.Conclusion: Overall, system performance, particularly in the areas of system bandwidth and precision in applications may be the future directions of hardware research.

26 January 2024 in Heliyon
Verified
Journal Article
Open access
CDChenling Ding
Chenling Ding
YZYibo Zhu
Yibo Zhu
SZShuyi Zhang
Shuyi Zhang
Zhanqi ZhaoZhanqi Zhao
Zhanqi Zhao
YGYuan Gao
Yuan Gao
ZLZhe Li
Zhe Li
Pulmonary embolism (PE) is a common worldwide disease with high mortality. Timely diagnosis and management of PE could significantly improve clinical outcomes. Electrical impedance tomography (EIT) is a novel noninvasive technique to monitor lung perfusion and help detect PE at the bedside. Here we present a case of clinical management of subsegmental PE with the help of the bilateral ventilation and perfusion(V/Q) asymmetry EIT image. A 72-year-old cancer patient with respiratory failure and acute kidney injury in the intensive care unit was suspected of PE based on his clinical manifestation. The contraindication of computed tomography pulmonary angiography (CTPA) for PE diagnosis prevented escalating anticoagulation therapy. Besides EIT ventilation and perfusion monitoring showed an abnormal asymmetry V/Q match between the bilateral lungs which promoted our decision to start systemic continuous anticoagulation therapy and improved the patient clinically. The following CTPA which clarified the diagnosis of PE suggests that the patient has benefited from our decision. For critically ill patients with suspected PE, the asymmetry of the EIT V/Q image may provide crucial objective information for clinical management.

15 February 2023 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Open access
ZLZhe Li
Zhe Li
YGYuan Gao
Yuan Gao
Zhanqi ZhaoZhanqi Zhao
Zhanqi Zhao