Zhanqi Zhao

Dr. Zhanqi Zhao

Furtwangen University, Furtwangen im Schwarzwald, Baden-Württemberg, Germany
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2016 in Thorax
Verified
Journal Article
Open access
PDF file
IFInéz Frerichs
Inéz Frerichs
MAMarcelo B P Amato
Marcelo B P Amato
AKAnton H van Kaam
Anton H van Kaam
DTDavid G Tingay
David G Tingay
Zhanqi ZhaoZhanqi Zhao
Zhanqi Zhao
TGTREND study group
TREND study group
Electrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function testing in patients with chronic lung diseases. As EIT becomes an established medical technology, it requires consensus examination, nomenclature, data analysis and interpretation schemes. Such consensus is needed to compare, understand and reproduce study findings from and among different research groups, to enable large clinical trials and, ultimately, routine clinical use. Recommendations of how EIT findings can be applied to generate diagnoses and impact clinical decision-making and therapy planning are required. This consensus paper was prepared by an international working group, collaborating on the clinical promotion of EIT called TRanslational EIT developmeNt stuDy group. It addresses the stated needs by providing (1) a new classification of core processes involved in chest EIT examinations and data analysis, (2) focus on clinical applications with structured reviews and outlooks (separately for adult and neonatal/paediatric patients), (3) a structured framework to categorise and understand the relationships among analysis approaches and their clinical roles, (4) consensus, unified terminology with clinical user-friendly definitions and explanations, (5) a review of all major work in thoracic EIT and (6) recommendations for future development (193 pages of online supplements systematically linked with the chief sections of the main document). We expect this information to be useful for clinicians and researchers working with EIT, as well as for industry producers of this technology.

4 August 2009 in Intensive Care Medicine
Verified
Journal Article
Closed access
PDF file
Zhanqi ZhaoZhanqi Zhao
Zhanqi Zhao
KMKnut Möller
Knut Möller
DSDaniel Steinmann
Daniel Steinmann
IFInéz Frerichs
Inéz Frerichs
JGJosef Guttmann
Josef Guttmann

30 January 2010 in Critical Care
Verified
Journal Article
Open access
PDF file
Zhanqi ZhaoZhanqi Zhao
Zhanqi Zhao
DSDaniel Steinmann
Daniel Steinmann
IFInéz Frerichs
Inéz Frerichs
JGJosef Guttmann
Josef Guttmann
Knut MöllerKnut Möller
Knut Möller
Introduction: Lung protective ventilation requires low tidal volume and suitable positive end-expiratory pressure (PEEP). To date, few methods have been accepted for clinical use to set the appropriate PEEP. The aim of this study was to test the feasibility of PEEP titration guided by ventilation homogeneity using the global inhomogeneity (GI) index based on electrical impedance tomography (EIT) images. Methods: In a retrospective study, 10 anesthetized patients with healthy lungs mechanically ventilated under volume-controlled mode were investigated. Ventilation distribution was monitored by EIT. A standardized incremental PEEP trial (PEEP from 0 to 28 mbar, 2 mbar per step) was conducted. During the PEEP trial, "optimal" PEEP level for each patient was determined when the air was most homogeneously distributed in the lung, indicated by the lowest GI index value. Two published methods for setting PEEP were included for comparison based on the maximum global dynamic compliance and the intra-tidal compliance-volume curve. Results: No significant differences in the results were observed between the GI index method (12.2 ± 4.6 mbar) and the dynamic compliance method (11.4 ± 2.3 mbar, P > 0.6), or between the GI index and the compliance-volume curve method (12.2 ± 4.9 mbar, P > 0.6). Conclusions: According to the results, it is feasible and reasonable to use the GI index to select the PEEP level with respect to ventilation homogeneity. The GI index may provide new insights into the relationship between lung mechanics and tidal volume distribution and may be used to guide ventilator settings.

30 June 2021 in Critical Care
Verified
Journal Article
Open access
PDF file
HHHuaiwu He
Huaiwu He
YCYi Chi
Yi Chi
YYYingying Yang
Yingying Yang
SYSiyi Yuan
Siyi Yuan
Yun LongYun Long
Yun Long
Zhanqi ZhaoZhanqi Zhao
Zhanqi Zhao
Background: Individualized positive end-expiratory pressure (PEEP) by electrical impedance tomography (EIT) has potential interest in the optimization of ventilation distribution in acute respiratory distress syndrome (ARDS). The aim of the study was to determine whether early individualized titration of PEEP with EIT improved outcomes in patients with ARDS. Methods: A total of 117 ARDS patients receiving mechanical ventilation were randomly assigned to EIT group (n = 61, PEEP adjusted based on ventilation distribution) or control group (n = 56, low PEEP/FiO2 table). The primary outcome was 28-day mortality. Secondary and exploratory outcomes were ventilator-free days, length of ICU stay, incidence of pneumothorax and barotrauma, and difference in Sequential Organ Failure Assessment (SOFA) score at day 1 (ΔD1-SOFA) and day 2 (ΔD2-SOFA) compared with baseline. Measurements and main results: There was no statistical difference in the value of PEEP between the EIT group and control group, but the combination of PEEP and FiO2 was different between groups. In the control group, a significantly positive correlation was found between the PEEP value and the corresponding FiO2 (r = 0.47, p < 0.00001) since a given matched table was used for PEEP settings. Diverse combinations of PEEP and FiO2 were found in the EIT group (r = 0.05, p = 0.68). There was no significant difference in mortality rate (21% vs. 27%, EIT vs. control, p = 0.63), ICU length of stay (13.0 (7.0, 25.0) vs 10.0 (7.0, 14.8), median (25th–75th percentile); p = 0.17), and ventilator-free days at day 28 (14.0 (2.0, 23.0) vs 19.0 (0.0, 24.0), p = 0.55) between the two groups. The incidence of new barotrauma was zero. Compared with control group, significantly lower ΔD1-SOFA and ΔD2-SOFA were found in the EIT group (p < 0.001) in a post hoc comparison. Moreover, the EIT group exhibited a significant decrease of SOFA at day 2 compared with baseline (paired t-test, difference by − 1 (− 3.5, 0), p = 0.001). However, the control group did show a similar decrease (difference by 1 (− 2, 2), p = 0.131). Conclusion: Our study showed a 6% absolute decrease in mortality in the EIT group: a statistically non-significant, but clinically non-negligible result. This result along with the showed improvement in organ function might justify further reserach to validate the beneficial effect of individualized EIT-guided PEEP setting on clinical outcomes of patients with ARDS. Trial registration: ClinicalTrials, NCT02361398. Registered 11 February 2015—prospectively registered, https://clinicaltrials.gov/show/NCT02361398.

1 October 2012 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
BVBarbara Vogt
Barbara Vogt
SPSven Pulletz
Sven Pulletz
GEGunnar Elke
Gunnar Elke
Zhanqi ZhaoZhanqi Zhao
Zhanqi Zhao
PZPeter Zabel
Peter Zabel
IFInéz Frerichs
Inéz Frerichs
Electrical impedance tomography (EIT) is a functional imaging modality capable of tracing continuously regional pulmonary gas volume changes. The aim of our study was to determine if EIT was able to assess spatial and temporal heterogeneity of ventilation during pulmonary function testing in 14 young (37 ± 10 yr, mean age ± SD) and 12 elderly (71 ± 9 yr) subjects without lung disease and in 33 patients with chronic obstructive pulmonary disease (71 ± 9 yr). EIT and spirometry examinations were performed during tidal breathing and a forced vital capacity (FVC) maneuver preceded by full inspiration to total lung capacity. Regional inspiratory vital capacity (IVC); FVC; forced expiratory volume in 1 s (FEV1); FEV1/FVC; times required to expire 25%, 50%, 75%, and 90% of FVC ( t25, t50, t75, t90); and tidal volume (VT) were determined in 912 EIT image pixels in the chest cross section. Coefficients of variation (CV) were calculated from all pixel values of IVC, FVC, FEV1, and VT to characterize the ventilation heterogeneity. The highest values were found in patients, and no differences existed between the healthy young and elderly subjects. Receiver-operating characteristics curves showed that CV of regional IVC, FVC, FEV1, and VT discriminated the young and elderly subjects from the patients. Frequency distributions of pixel FEV1/FVC, t25, t50, t75, and t90 identified the highest ventilation heterogeneity in patients but distinguished also the healthy young from the elderly subjects. These results indicate that EIT may provide additional information during pulmonary function testing and identify pathologic and age-related spatial and temporal heterogeneity of regional lung function.

17 January 2019 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
Zhanqi ZhaoZhanqi Zhao
Zhanqi Zhao
MCMei-Ying Chang
Mei-Ying Chang
MCMei-Yun Chang
Mei-Yun Chang
CGChien-Hung Gow
Chien-Hung Gow
JZJia-Hao Zhang
Jia-Hao Zhang
Knut MöllerKnut Möller
Knut Möller
The study objective was to compare titration of positive end-expiratory pressure (PEEP) with electrical impedance tomography (EIT) and with ventilator-embedded pressure–volume loop in severe acute respiratory distress syndrome (ARDS). We have designed a prospective study with historical control group. Twenty-four severe ARDS patients (arterial oxygen partial pressure to fractional inspired oxygen ratio, PaO2/FiO2 < 100 mmHg) were included in the EIT group and examined prospectively. Data from another 31 severe ARDS patients were evaluated retrospectively (control group). All patients were receiving medical care under identical general support guidelines and protective mechanical ventilation. The PEEP level selected in the EIT group was the intercept point of cumulated collapse and overdistension percentages curves. In the control group, optimal PEEP was selected 2 cmH2O above the lower inflection point on the static pressure–volume curve. Patients in the EIT group were younger (P < 0.05), and their mean plateau pressure was 1.5 cmH2O higher (P < 0.01). No differences in other baseline parameters such as APACHE II score, PaO2/FiO2, initial PEEP, driving pressure, tidal volume, and respiratory system compliance were found. Two hours after the first PEEP titration, significantly higher PEEP, compliance, and lower driving pressure were found in the EIT group (P < 0.01). Hospital survival rates were 66.7% (16 of 24 patients) in the EIT group and 48.4% (15 of 31) in the control group. Identical rates were found regarding the weaning success rate: 66.7% in the EIT group and 48.4% in the control group. In severe ARDS patients, it was feasible and safe to guide PEEP titration with EIT at the bedside. As compared with pressure–volume curve, the EIT-guided PEEP titration may be associated with improved oxygenation, compliance, driving pressure, and weaning success rate. The findings encourage further randomized control study with a larger sample size and potentially less bias in the baseline data. Trial Registration NCT03112512