The hyperburner is a key component of a TBCC engine, and its reliable ignition and stable operation are critical. The gliding arc plasma igniter driven by differential pressure has the technical advantages of low energy consumption and high jet temperature. In this paper, the electrical and flow characteristics of the gliding arc plasma igniter are studied, and the basic ignition experiment in the hyperburner is carried out. Electrical characteristic experiments show that the discharge duration, the evolution of the gliding arc and the fracture frequency are affected by the pressure difference between the inlet and outlet of the igniter (Δp). With the increase in Δp, the frequency of the trapezoidal envelope in the voltage and current waveforms increases, and the frequency of the evolution and fracture of the gliding arc increases. The continuous discharge time of the gliding arc decreases when Δp = 550 Torr. The flow characteristic experiments show that the velocity of the swirl sheath is increased and the protective effect on the gliding arc is enhanced with the increase in Δp. In the range of 20–550 Torr, the jet length first increases and then decreases with the increase in Δp. The jet length reaches a maximum of 31 mm at Δp = 50 Torr. Basic ignition experiments show that proper Δp can widen the lean ignition limit and shorten the ignition delay time. In the working conditions of this paper, the ignition effect is the best when Δp = 350 Torr, which can widen the lean ignition limit by 37.5% and shorten the ignition delay time by 17%. After increasing the oil–gas ratios, the combustion is more complete and the ignition delay time can be shortened by 93.1% at most.
Flame holders are widely used in ramjet combustors. We propose using surface nanosecond-pulsed surface-dielectric-barrier-discharge (NS-DBD) to manipulate the flame-holder flow field experimentally. The electrical characteristics, induced flow performance, and temperature distribution of NS-DBD were investigated via the electrical and optical measurement system. In the filamentary discharge mode, the discharge energy rose with decrease of the ambient pressure. The discharge pattern of NS-DBD changed from filamentous to uniform around 5 kPa. Starting-vortex intensity and jet-flow angle relative to the wall increased at low pressure. The recirculation zone was asymmetrical at pressures above 60 kPa. The recirculation zone’s area and length were smaller at lower pressures, but when the actuator was operating, the recirculation zone was nearly 11.8% longer. The vorticity increased with pressure. When the pulse width was 300 ns, the actuator had the greatest effect, and the low velocity region (LVR) area and the fuel–air-mixture residence time (FMRT) could be increased by 31.8% and 20.5%, respectively. The actuator had a smaller widening effect on the LVR area at lower pressure. Rising-edge time should increase with pressure to optimize LVR increase; it should be above 300 ns to optimize FMRT increase. We conclude that NS-DBD is a viable method of controlling flame-holder airflow at low pressure.
Improving the performance of flame holders has been a key focus of research on ramjet combustors. The plasma actuator has the potential to improve the ignition performance by manipulating the flow field of the flame holder. In this study, a plasma-actuated flame holder was designed. The aim of this study is to improve the performance of ramjet combustor by applying plasma discharge to the flame holder. The aerodynamic effects and ignition performance of the flame holder were investigated. The results demonstrated that the induced jet direction of the surface arc discharge was perpendicular to the actuator. The induced jet dissipated faster at lower pressures. The aerodynamic actuation intensity and jet area increased with the number of channels of surface arc discharges. Increasing discharge frequencies can increase the discharge times and jet height. The aerodynamic effects under a microsecond pulse duration were better than those under a nanosecond pulse duration. Actuators installed on the inside surface showed better performance than those installed outside. Under different total flow temperature conditions, the plasma-actuated flame holder significantly extended the ignition pressure limit and increased the combustion efficiency by 9.12% and 4.3% on average, respectively.