Although electrosurgical instruments are widely used in surgery to cut tissue layers or to achieve hemostasis by coagulation (electrocautery), only little information is available concerning the inflammatory or immune response towards the debris generated. Given the elevated local temperatures required for successful electrocautery, the remaining debris is likely to contain a plethora of compounds entirely novel to the intracorporal setting. A very common in vitro method to study cell migration after mechanical damage is the scratch assay, however, there is no established model for thermomechanical damage to characterise cellular reactions. In this study, we established a new in vitro model to investigate exposure to high temperature in a carefully controlled cell culture system. Heatable thermostat-controlled aluminium stamps were developed to induce local damage in primary human umbilical vein endothelial cells (HUVEC). The thermomechanical damage invoked is reproducibly locally confined, therefore allowing studies, under the same experimental conditions, of cells affected to various degrees as well as of unaffected cells. We show that the unaffected cells surrounding the thermomechanical damage zone are able to migrate into the damaged area, resulting in a complete closure of the ‘wound’ within 48 h. Initial studies have shown that there are significant morphological and biological differences in endothelial cells after thermomechanical damage compared to the mechanical damage inflicted by using the unheated stamp as a control. Accordingly, after thermomechanical damage, cell death as well as cell protection programs were activated. Mononuclear cells adhered in the area adjacent to thermomechanical damage, but not to the zone of mechanical damage. Therefore, our model can help to understand the differences in wound healing during the early phase of regeneration after thermomechanical vs. mechanical damage. Furthermore, this model lends itself to study the response of other cells, thus broadening the range of thermal injuries that can be analysed.
Hematopoietic stem cell transplantation is successfully applied since the late 1950s; however, its efficacy still needs to be increased. A promising strategy is to transplant high numbers of pluripotent hematopoietic stem cells (HSCs). Therefore, an improved ex vivo culture system that supports proliferation and maintains HSC pluripotency would override possible limitations in cell numbers gained from donors. To model the natural HSC niche in vitro, we optimized the HSC medium composition with a panel of cytokines and valproic acid and used an artificial 3D bone marrow-like scaffold made of polydimethylsiloxane (PDMS). This 3D scaffold offered a suitable platform to amplify human HSCs in vitro and, simultaneously, to support their viability, multipotency and ability for self-renewal. Silicon oxide-covering of PDMS structures further improved amplification of CD34+ cells, although the conservation of naïve HSCs was better on non-covered 3D PDMS. Finally, we found that HSC cultivated on non-covered 3D PDMS generated most pluripotent colonies within colony forming unit assays. In conclusion, by combining biological and biotechnological approaches, we optimized in vitro HSCs culture conditions, resulting in improved amplification, multipotency maintenance and vitality of HSCs.
1 April 2015 in Materials Science and Engineering: C