Andreas Schober

Prof. Dr. Andreas Schober


Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
AWAdam Williamson
Adam Williamson
SSSukhdeep Singh
Sukhdeep Singh
UFUta Fernekorn
Uta Fernekorn
ASAndreas Schober
Andreas Schober
As significant advancements in technology focused on Organ-on-a-chip continue, it is feasible to consider the future of Body-on-a-chip technology. With serious work being done to realize functioning artificial livers, kidneys, hearts, and lungs on chips, the next step is not only to interconnect these organs but also to consider the integration of stem cell technology to create interconnected patient-specific organs. Such a patient-specific Body-on-a-chip requires a sophisticated set of tools for micropattering cell cultures in 3D to create interconnected tissue-like organ structures. This review discusses advanced methods of the past two years in on-Chip organs, the complex 3D patterning of cultures and state-of-the-art scaffolding, and discusses some of the most relevant advancements in human-induced pluripotent stem cell (hiPSC) research applied to these organs and scaffolds for the future of a patient-specific Body-on-a-chip. We anticipate that such a technology would have a wide area of application, primarily benefiting drug development, chemical safety testing, and disease modeling.

4 October 2016 in Advanced Energy Materials
Verified
Journal Article
Closed access
PDF file
MBMartin Baca
Martin Baca
SSSukhdeep Singh
Sukhdeep Singh
MGMichael Gebinoga
Michael Gebinoga
FWFrank Weise
Frank Weise
GSGregor Schlingloff
Gregor Schlingloff
ASAndreas Schober
Andreas Schober

14 July 2021 in ChemistrySelect
Verified
Journal Article
Open access
PDF file
LZLisa Zeußel
Lisa Zeußel
PMPatrick Mai
Patrick Mai
SSSanjay Sharma
Sanjay Sharma
ASAndreas Schober
Andreas Schober
SRShizhan Ren
Shizhan Ren
SSSukhdeep Singh
Sukhdeep Singh
In the past few years Meldrum's acid furfural conjugate (MAFC) have been extensively explored as starting material for the synthesis of photo switchable donor acceptor stenhouse adducts (DASA). Hereby, we have explored the interaction of MAFC with various amino acids. To our surprise, nitrogen rich amino acids like lysine and arginine interact spontaneously with MAFC to give colored adduct immediately, whereas other amino acids, including nitrogen rich histidine, didn't show any coloration. Naked eye detection of lysine in benign solvent make this reagent an attractive new entry to the collection of chemosensors for the colorimetric detection of lysine and arginine. Intense coloration corresponds to the absorption at 514 nm under UV‐Vis spectrometer. Lowest concentration of 100 μ m can be detected with UV‐Vis spectrometer. NMR titrations reveals that the appearance of color is due to ring opening of a furfural that leads to the formation of conjugated triene species. Compared to previously reported chemosensors for lysine and arginine, MAFC offers advantages including simple synthesis, easy handling, high speed, low cost, good sensitivity/selectivity.

22 June 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LML. Marx-Blümel
L. Marx-Blümel
CMChristian Marx
Christian Marx
FWFrank Weise
Frank Weise
JFJ. Frey
J. Frey
BPB. Perner
B. Perner
ASAndreas Schober
Andreas Schober
Hematopoietic stem cell transplantation is successfully applied since the late 1950s; however, its efficacy still needs to be increased. A promising strategy is to transplant high numbers of pluripotent hematopoietic stem cells (HSCs). Therefore, an improved ex vivo culture system that supports proliferation and maintains HSC pluripotency would override possible limitations in cell numbers gained from donors. To model the natural HSC niche in vitro, we optimized the HSC medium composition with a panel of cytokines and valproic acid and used an artificial 3D bone marrow-like scaffold made of polydimethylsiloxane (PDMS). This 3D scaffold offered a suitable platform to amplify human HSCs in vitro and, simultaneously, to support their viability, multipotency and ability for self-renewal. Silicon oxide-covering of PDMS structures further improved amplification of CD34+ cells, although the conservation of naïve HSCs was better on non-covered 3D PDMS. Finally, we found that HSC cultivated on non-covered 3D PDMS generated most pluripotent colonies within colony forming unit assays. In conclusion, by combining biological and biotechnological approaches, we optimized in vitro HSCs culture conditions, resulting in improved amplification, multipotency maintenance and vitality of HSCs.

1 July 2009 in Bioorganic & Medicinal Chemistry Letters
Verified
Journal Article
Closed access
DRDaniel Riester
Daniel Riester
CHChristian Hildmann
Christian Hildmann
PHPatricia Haus
Patricia Haus
AGAntonia Galetovic
Antonia Galetovic
ASAndreas Schober
Andreas Schober
FMFranz-Josef Meyer-Almes
Franz-Josef Meyer-Almes

5 April 2018 in Biosensors
Verified
Journal Article
Open access
PDF file
Heike BartschHeike Bartsch
Heike Bartsch
MBMartin Baca
Martin Baca
UFUta Fernekorn
Uta Fernekorn
JMJens Müller
Jens Müller
ASAndreas Schober
Andreas Schober
Hartmut F. WitteHartmut F. Witte
Hartmut F. Witte
Multi-electrode arrays find application in electrophysiological recordings. The quality of the captured signals depends on the interfacial contact between electrogenic cells and the electronic system. Therefore, it requires reliable low-impedance electrodes. Low-temperature cofired ceramic technology offers a suitable platform for rapid prototyping of biological reactors and can provide both stable fluid supply and integrated bio-hardware interfaces for recordings in electrogenic cell cultures. The 3D assembly of thick film gold electrodes in in vitro bio-reactors has been demonstrated for neuronal recordings. However, especially when dimensions become small, their performance varies strongly. This work investigates the influence of different coatings on thick film gold electrodes with regard to their influence on impedance behavior. PEDOT:PSS layer, titanium oxynitride and laminin coatings are deposited on LTCC gold electrodes using different 2D and 3D MEA chip designs. Their impedance characteristics are compared and discussed. Titanium oxynitride layers emerged as suitable functionalization. Small 86-µm-electrodes have a serial resistance Rs of 32 kOhm and serial capacitance Cs of 4.1 pF at 1 kHz. Thick film gold electrodes with such coatings are thus qualified for signal recording in 3-dimensional in vitro cell cultures.