29 March 2022 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
DKDavid C. Klonoff
David C. Klonoff
JWJing Wang
Jing Wang
DRDavid Rodbard
David Rodbard
MKMichael A. Kohn
Michael A. Kohn
CLChengdong Li
Chengdong Li
BKBoris Kovatchev
Boris Kovatchev
Background: A composite metric for the quality of glycemia from continuous glucose monitor (CGM) tracings could be useful for assisting with basic clinical interpretation of CGM data. Methods: We assembled a data set of 14-day CGM tracings from 225 insulin-treated adults with diabetes. Using a balanced incomplete block design, 330 clinicians who were highly experienced with CGM analysis and interpretation ranked the CGM tracings from best to worst quality of glycemia. We used principal component analysis and multiple regressions to develop a model to predict the clinician ranking based on seven standard metrics in an Ambulatory Glucose Profile: very low–glucose and low-glucose hypoglycemia; very high–glucose and high-glucose hyperglycemia; time in range; mean glucose; and coefficient of variation. Results: The analysis showed that clinician rankings depend on two components, one related to hypoglycemia that gives more weight to very low-glucose than to low-glucose and the other related to hyperglycemia that likewise gives greater weight to very high-glucose than to high-glucose. These two components should be calculated and displayed separately, but they can also be combined into a single Glycemia Risk Index (GRI) that corresponds closely to the clinician rankings of the overall quality of glycemia (r = 0.95). The GRI can be displayed graphically on a GRI Grid with the hypoglycemia component on the horizontal axis and the hyperglycemia component on the vertical axis. Diagonal lines divide the graph into five zones (quintiles) corresponding to the best (0th to 20th percentile) to worst (81st to 100th percentile) overall quality of glycemia. The GRI Grid enables users to track sequential changes within an individual over time and compare groups of individuals. Conclusion: The GRI is a single-number summary of the quality of glycemia. Its hypoglycemia and hyperglycemia components provide actionable scores and a graphical display (the GRI Grid) that can be used by clinicians and researchers to determine the glycemic effects of prescribed and investigational treatments.

8 January 2019 in Diabetes Technology & Therapeutics
Verified
Journal Article
Open access
GFGregory Forlenza
Gregory Forlenza
OPOrit Pinhas-Hamiel
Orit Pinhas-Hamiel
DLDavid R. Liljenquist
David R. Liljenquist
DSDorothy I. Shulman
Dorothy I. Shulman
TBTimothy S. Bailey
Timothy S. Bailey
FKFrancine R. Kaufman
Francine R. Kaufman
Objective: To evaluate the safety of in-home use of the MiniMed™ 670G system with SmartGuard™ technology in children with type 1 diabetes (T1D). Methods: Participants ( N = 105, ages 7–13 years, mean age 10.8 ± 1.8 years) were enrolled at nine centers (eight in the United States and one in Israel) and completed a 2-week baseline run-in phase in Manual Mode followed by a 3-month study phase with Auto Mode enabled. Sensor glucose (SG), glycated hemoglobin (HbA 1c ), percentage of SG values across glucose ranges, and SG variability, during the run-in and study phases were compared. Participants underwent frequent sample testing with i-STAT ® venous reference measurement during a hotel period (6 days/5 nights) to evaluate the system's continuous glucose monitoring performance. Results: Auto Mode was used a median of 81% of the time. From baseline to end of study, overall SG dropped by 6.9 ± 17.2 mg/dL ( P < 0.001), HbA 1c decreased from 7.9% ± 0.8% to 7.5% ± 0.6% ( P < 0.001), percentage of time in target glucose range (70–180 mg/dL) increased from 56.2% ± 11.4% to 65.0% ± 7.7% ( P < 0.001), and the SG coefficient of variation decreased from 39.6% ± 5.4% to 38.5% ± 3.8% ( P = 0.009). The percentage of SG values within target glucose range was 68.2% ± 9.1% and that of i-STAT reference values was 65.6% ± 17.7%. The percentage of values within 20%/20 of the i-STAT reference was 85.2%. There were no episodes of severe hypoglycemia or diabetic ketoacidosis during the study phase. Conclusion: In-home use of MiniMed 670G system Auto Mode for 3 months by children with T1D, similar to MiniMed 670G system use by adolescents and adults with T1D, was safe and associated with reduced HbA 1c levels and increased time in target glucose range, compared with baseline.

20 April 2021 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
EIElvira Isganaitis
Elvira Isganaitis
DRDan Raghinaru
Dan Raghinaru
LALouise Ambler-Osborn
Louise Ambler-Osborn
JPJordan E Pinsker
Jordan E Pinsker
BBBruce A Buckingham
Bruce A Buckingham
LLLori Mb Laffel
Lori Mb Laffel
Objective: To assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes. Research Design and Methods: Prespecified subanalysis of outcomes in adolescents and young adults aged 14–24 years old with type 1 diabetes in a previously published 6-month multicenter randomized trial. Participants were randomly assigned 2:1 to CLC (Tandem Control-IQ) or sensor augmented pump (SAP, various pumps+Dexcom G6 CGM) and followed for 6 months. Results: Mean age of the 63 participants was 17 years, median type 1 diabetes duration was 7 years, and mean baseline HbA1c was 8.1%. All 63 completed the trial. Time in range (TIR) increased by 13% with CLC versus decreasing by 1% with SAP (adjusted treatment group difference = +13% [+3.1 h/day]; 95% confidence interval [CI] 9–16, P < 0.001), which largely reflected a reduction in time >180 mg/dL (adjusted difference −12% [−2.9 h/day], P < 0.001). Time <70 mg/dL decreased by 1.6% with CLC versus 0.3% with SAP (adjusted difference −0.7% [−10 min/day], 95% CI −1.0% to −0.2%, P = 0.002). CLC use averaged 89% of the time for 6 months. The mean adjusted difference in HbA1c after 6 months was 0.30% in CLC versus SAP (95% CI −0.67 to +0.08, P = 0.13). There was one diabetic ketoacidosis episode in the CLC group. Conclusions: CLC use for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, CLC has the potential to improve glycemic outcomes in this challenging age group. The clinical trial was registered with ClinicalTrials.gov (NCT03563313).

8 August 2024 in Diabetes Technology & Therapeutics
Verified
Journal Article
Open access
GFGregory Forlenza
Gregory Forlenza
DDDaniel J. DeSalvo
Daniel J. DeSalvo
GAGrazia Aleppo
Grazia Aleppo
EWEmma G. Wilmot
Emma G. Wilmot
CBCari Berget
Cari Berget
JSJennifer L. Sherr
Jennifer L. Sherr
Background: The Omnipod ® 5 Automated Insulin Delivery System was associated with favorable glycemic outcomes for people with type 1 diabetes (T1D) in two pivotal clinical trials. Real-world evidence is needed to explore effectiveness in nonstudy conditions. Methods: A retrospective analysis of the United States Omnipod 5 System users (aged ≥2 years) with T1D and sufficient data (≥90 days of data; ≥75% of days with ≥220 continuous glucose monitor readings/day) available in Insulet Corporation's device and person-reported datasets as of July 2023 was performed. Target glucose setting usage (i.e., 110–150 mg/dL in 10 mg/dL increments) was summarized and glycemic outcomes were examined. Subgroup analyses of those using the lowest average glucose target (110 mg/dL) and stratification by baseline characteristics (e.g., age, prior therapy, health insurance coverage) were conducted. Results: In total, 69,902 users were included. Multiple and higher glucose targets were more commonly used in younger age groups. Median percentage of time in range (TIR; 70–180 mg/dL) was 68.8%, 61.3%, and 53.6% for users with average glucose targets of 110, 120, and 130–150 mg/dL, respectively, with minimal time <70 mg/dL (all median <1.13%). Among those with an average glucose target of 110 mg/dL ( n = 37,640), median TIR was 65.0% in children and adolescents (2–17 years) and 69.9% in adults (≥18 years). Subgroup analyses of users transitioning from Omnipod DASH or multiple daily injections and of Medicaid/Medicare users demonstrated favorable glycemic outcomes among these groups. Conclusion: These glycemic outcomes from a large and diverse sample of nearly 70,000 children and adults demonstrate effective use of the Omnipod 5 System under real-world conditions.

10 December 2024 in Diabetologia
Verified
Journal Article
Open access
PDF file
OMOthmar Moser
Othmar Moser
DZDessi Zaharieva
Dessi Zaharieva
PAPeter Adolfsson
Peter Adolfsson
TBTadej Battelino
Tadej Battelino
RBRichard M. Bracken
Richard M. Bracken
MRMichael C Riddell
Michael C Riddell
Regular physical activity and exercise (PA) are cornerstones of diabetes care for individuals with type 1 diabetes. In recent years, the availability of automated insulin delivery (AID) systems has improved the ability of people with type 1 diabetes to achieve the recommended glucose target ranges. PA provide additional health benefits but can cause glucose fluctuations, which challenges current AID systems. While an increasing number of clinical trials and reviews are being published on different AID systems and PA, it seems prudent at this time to collate this information and develop a position statement on the topic. This joint European Association for the Study of Diabetes (EASD)/International Society for Pediatric and Adolescent Diabetes (ISPAD) position statement reviews current evidence on AID systems and provides detailed clinical practice points for managing PA in children, adolescents and adults with type 1 diabetes using AID technology. It discusses each commercially available AID system individually and provides guidance on their use in PA. Additionally, it addresses different glucose responses to PA and provides stratified therapy options to maintain glucose levels within the target ranges for these age groups. Graphical Abstract

25 November 2021 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
LMLaurel H. Messer
Laurel H. Messer
CBCari Berget
Cari Berget
LPLaura Pyle
Laura Pyle
TVTim Vigers
Tim Vigers
ECErin Cobry
Erin Cobry
GFGregory Forlenza
Gregory Forlenza
Objective: To describe real-world outcomes for youth using the Tandem t:slim X2 insulin pump with Control-IQ technology (“Control-IQ”) for 6 months at a large pediatric clinic. Methods: Youth with type 1 diabetes, who started Control-IQ for routine care, were prospectively followed. Data on system use and glycemic control were collected before Control-IQ start, and at 1, 3, and 6 months after start. Mixed models assessed change across time; interactions with baseline hemoglobin A1c (HbA1c) and age were tested. Results: In 191 youth (median age 14, 47% female, and median HbA1c 7.6%), percent time with glucose levels 70–180 mg/dL (time-in-range [TIR]) improved from 57% at baseline to 66% at 6 months ( P < 0.001). The proportion of participants reaching TIR target (>70%) doubled from 23.5% at baseline to 47.8% at 3 months, sustaining at 46.7% at 6 months ( P < 0.001). Glucose management indicator (approximation of HbA1c) improved from 7.5% at baseline to 7.1% at 3 months and 7.2% at 6 months ( P < 0.001). Those with higher baseline HbA1c experienced the most substantial improvements in glycemic control. Percent time using the Control-IQ feature was 86.4% at 6 months, and <4% of cohort discontinued use. Conclusion: The Control-IQ system clinically and significantly improved glycemic control in a large sample of youth. System use was high at 6 months, with only a small proportion discontinuing use, indicating potential for sustaining results long term.