Tomas Kron

Dr. Tomas Kron

Department of Physical Sciences, Peter MacCallum Cancer Centre, 305 Grattan Street, Melbourne, VIC 3000, Australia
orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 1998 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
Tomas KronTomas Kron
Tomas Kron
LDLisa Duggan
Lisa Duggan
TSTony Smith
Tony Smith
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
MBMartin Butson
Martin Butson
KHKazuyuki Hyodo
Kazuyuki Hyodo
Accurate dosimetry is particularly difficult for low- to medium-energy x-rays as various interaction processes with different dependences on material properties determine the dose distribution in tissue and radiation detectors. Monoenergetic x-rays from synchrotron radiation offer the unique opportunity to study the dose response variation with photon energy of radiation detectors without the compounding effect of the spectral distribution of x-rays from conventional sources. The variation of dose response with photon energies between 10 and 99.6 keV was studied for two TLD materials (LiF:Mg,Ti and LiF:Mg,Cu,P), MOSFET semiconductors, radiographic and radiochromic film. The dose response at synchrotron radiation energies was compared with the one for several superficial/orthovoltage radiation qualities (HVL 1.4 mm Al to 4 mm Cu) and megavoltage photons from a medical linear accelerator. A calibrated parallel plate ionization chamber was taken as the reference dosimeter. The variation of response with x-ray energy was modelled using a two-component model that allows determination of the energy for maximum response as well as its magnitude. MOSFET detectors and the radiographic film were found to overrespond to low-energy x-rays by up to a factor of 7 and 12 respectively, while the radiochromic film underestimated the dose by approximately a factor of 2 at 24 keV. The TLDs showed a slight overresponse with LiF:Mg, Cu, P demonstrating better tissue equivalence than LiF:Mg, Ti (maximum deviation from water less than 25%). The results of the present study demonstrate the usefulness of monoenergetic photons for the study of the energy response of radiation detectors. The variations in energy response observed for the MOSFET detectors and GAF chromic film emphasize the need for a correction for individual dosimeters if accurate dosimetry of low- to medium-energy x-rays is attempted.

1 November 2011 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
FFFarshad Foroudi
Farshad Foroudi
JWJacky Wong
Jacky Wong
Tomas KronTomas Kron
Tomas Kron
ARAldo Rolfo
Aldo Rolfo
AHAnnette Haworth
Annette Haworth
GDGillian Duchesne
Gillian Duchesne

1 May 2015 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
SSShankar Siva
Shankar Siva
RTRoshini Thomas
Roshini Thomas
JCJason Callahan
Jason Callahan
NHNicholas Hardcastle
Nicholas Hardcastle
DPDaniel Pham
Daniel Pham
MHMichael S. Hofman
Michael S. Hofman

1 September 1999 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
Tomas KronTomas Kron
Tomas Kron
Thermoluminescence dosimetry (TLD) features many advantages such as small detector size and close tissue equivalence that make it useful for a variety of applications in medicine. In medical imaging the high sensitivity of TLD materials such as LiF:Mg,Cu,P and Al2O3:C enables risk assessment even for low dose procedures. In radiotherapy, the fact that no cables are required during the measurement allows the use of TLDs inside tissue-equivalent phantoms to verify radiation doses delivered in new treatment techniques. These features make TLD also the most versatile in vivo dosimetry tool allowing dose assessments directly on patients during diagnostic or therapeutic procedures. In addition to these clinical uses, TLD is widely employed for quality assurance in medicine. Dosimetric intercomparisons between different centres and spot checks of dose delivered in diagnostic procedures have found their way into many national and international guidelines for best practice.

28 June 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
Tomas KronTomas Kron
Tomas Kron
JLJoerg Lehmann
Joerg Lehmann
PGPeter Greer
Peter Greer
Dosimetry of ionising radiation is a well-established and mature branch of physical sciences with many applications in medicine and biology. In particular radiotherapy relies on dosimetry for optimisation of cancer treatment and avoidance of severe toxicity for patients. Several novel developments in radiotherapy have introduced new challenges for dosimetry with small and dynamically changing radiation fields being central to many of these applications such as stereotactic ablative body radiotherapy and intensity modulated radiation therapy. There is also an increasing awareness of low doses given to structures not in the target region and the associated risk of secondary cancer induction. Here accurate dosimetry is important not only for treatment optimisation but also for the generation of data that can inform radiation protection approaches in the future. The article introduces some of the challenges and highlights the interdependence of dosimetric calculations and measurements. Dosimetric concepts are explored in the context of six application fields: reference dosimetry, small fields, low dose out of field, in vivo dosimetry, brachytherapy and auditing of radiotherapy practice. Recent developments of dosimeters that can be used for these purposes are discussed using spatial resolution and number of dimensions for measurement as sorting criteria. While dosimetry is ever evolving to address the needs of advancing applications of radiation in medicine two fundamental issues remain: the accuracy of the measurement from a scientific perspective and the importance to link the measurement to a clinically relevant question. This review aims to provide an update on both of these.

7 October 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SSSiva Shankar
Siva Shankar
MMMichael MacManus
Michael MacManus
Tomas KronTomas Kron
Tomas Kron
NBNickala Best
Nickala Best
JSJai Smith
Jai Smith
OMOlga Martin
Olga Martin
Lung inflammation leading to pulmonary toxicity after radiotherapy (RT) can occur in patients with non-small cell lung cancer (NSCLC). We investigated the kinetics of RT induced plasma inflammatory cytokines in these patients in order to identify clinical predictors of toxicity. In 12 NSCLC patients, RT to 60 Gy (30 fractions over 6 weeks) was delivered; 6 received concurrent chemoradiation (chemoRT) and 6 received RT alone. Blood samples were taken before therapy, at 1 and 24 hours after delivery of the 1st fraction, 4 weeks into RT, and 12 weeks after completion of treatment, for analysis of a panel of 22 plasma cytokines. The severity of respiratory toxicities were recorded using common terminology criteria for adverse events (CTCAE) v4.0. Twelve cytokines were detected in response to RT, of which ten demonstrated significant temporal changes in plasma concentration. For Eotaxin, IL-33, IL-6, MDC, MIP-1α and VEGF, plasma concentrations were dependent upon treatment group (chemoRT vs RT alone, all p-values <0.05), whilst concentrations of MCP-1, IP-10, MCP-3, MIP-1β, TIMP-1 and TNF-α were not. Mean lung radiation dose correlated with a reduction at 1 hour in plasma levels of IP-10 (r2 = 0.858, p<0.01), MCP-1 (r2 = 0.653, p<0.01), MCP-3 (r2 = 0.721, p<0.01), and IL-6 (r2 = 0.531, p = 0.02). Patients who sustained pulmonary toxicity demonstrated significantly different levels of IP-10 and MCP-1 at 1 hour, and Eotaxin, IL-6 and TIMP-1 concentration at 24 hours (all p-values <0.05) when compared to patients without respiratory toxicity. Inflammatory cytokines were induced in NSCLC patients during and after RT. Early changes in levels of IP-10, MCP-1, Eotaxin, IL-6 and TIMP-1 were associated with higher grade toxicity. Measurement of cytokine concentrations during RT could help predict lung toxicity and lead to new therapeutic strategies.