Emilios Leonidas

Mr. Emilios Leonidas

University of Sheffield, Sheffield, UK
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Emilios LeonidasEmilios Leonidas
Emilios Leonidas
SASabino Ayvar-Soberanis
Sabino Ayvar-Soberanis
HLHatim Laalej
Hatim Laalej
SFStephen Fitzpatrick
Stephen Fitzpatrick
JWJon Willlmott
Jon Willlmott
During the machining process, substantial thermal loads are generated due to tribological factors and plastic deformation. The increase in temperature during the cutting process can lead to accelerated tool wear, reducing the tool’s lifespan; the degradation of machining accuracy in the form of dimensional inaccuracies; and thermally induced defects affecting the metallurgical properties of the machined component. These effects can lead to a significant increase in operational costs and waste which deviate from the sustainability goals of Industry 4.0. Temperature is an important machining response; however, it is one of the most difficult factors to monitor, especially in high-speed machining applications such as drilling and milling, because of the high rotational speeds of the cutting tool and the aggressive machining environments. In this article, thermocouple and infrared radiation temperature measurement methods used by researchers to monitor temperature during turning, drilling and milling operations are reviewed. The major merits and limitations of each temperature measurement methodology are discussed and evaluated. Thermocouples offer a relatively inexpensive solution; however, they are prone to calibration drifts and their response times are insufficient to capture rapid temperature changes in high-speed operations. Fibre optic infrared thermometers have very fast response times; however, they can be relatively expensive and require a more robust implementation. It was found that no one temperature measurement methodology is ideal for all machining operations. The most suitable temperature measurement method can be selected by individual researchers based upon their experimental requirements using critical criteria, which include the expected temperature range, the sensor sensitivity to noise, responsiveness and cost.

30 September 2023 in Construction and Building Materials
Verified
Journal Article
Open access
YLYufeng Lai
Yufeng Lai
XLXuanqi Liu
Xuanqi Liu
YLYifan Li
Yifan Li
Emilios LeonidasEmilios Leonidas
Emilios Leonidas
CFCallum Fisk
Callum Fisk
JWJon Willlmott
Jon Willlmott

30 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Emilios LeonidasEmilios Leonidas
Emilios Leonidas
MHMatthew Hobbs
Matthew Hobbs
SASabino Ayvar-Soberanis
Sabino Ayvar-Soberanis
HLHatim Laalej
Hatim Laalej
CFCallum Fisk
Callum Fisk
JWJon Willlmott
Jon Willlmott
Infrared radiation thermometers (IRTs) overcome many of the limitations of thermocouples, particularly responsiveness and calibration drift. The main challenge with radiation thermometry is the fast and reliable measurement of temperatures close to room temperature. A new IRT which is sensitive to wavelengths between 3 μm and 11 μm was developed and tested in a laboratory setting. It is based on an uncooled indium arsenide antimony (InAsSb) photodiode, a transimpedance amplifier, and a silver halogenide fibre optic cable transmissive in the mid- to long-wave infrared region. The prototype IRT was capable of measuring temperatures between 35 °C and 100 °C at an integration time of 5 ms and a temperature range between 40 °C and 100 °C at an integration time of 1 ms, with a root mean square (RMS) noise level of less than 0.5 °C. The thermometer was calibrated against Planck’s law using a five-point calibration, leading to a measurement uncertainty within ±1.5 °C over the aforementioned temperature range. The thermometer was tested against a thermocouple during drilling operations of polyether ether ketone (PEEK) plastic to measure the temperature of the drill bit during the material removal process. Future versions of the thermometer are intended to be used as a thermocouple replacement in high-speed, near-ambient temperature measurement applications, such as electric motor condition monitoring; battery protection; and machining of polymers and composite materials, such as carbon-fibre-reinforced plastic (CFRP).


16 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LKLouis Karapateas
Louis Karapateas
Emilios LeonidasEmilios Leonidas
Emilios Leonidas
XMXiangfei Meng
Xiangfei Meng
YLYufeng Lai
Yufeng Lai
Yang ZhangYang Zhang
Yang Zhang
MHMatthew Hobbs
Matthew Hobbs
This study presents a novel approach to analysing the early stages of the combustion process by measuring the surface temperature of a kerosene droplet from its point of ignition through to its evaporation. An indium arsenide antimonide (InAsSb) photodiode-based infrared radiation thermometer (IRT), operating between 3 μm and 11 μm in wavelength, was designed to enable non-contact, low-temperature sensing with an acquisition time of 500 μs. Integrated with a data acquisition unit (DAQ), the instrument captures the transient combustion stages occurring below the droplet’s boiling point of 300 °C. The instrument was assessed against industry standards and demonstrated a measurement uncertainty of ±2 °C, confirming suitability within the performance bounds of commercial instrumentation. The IRT was deployed to measure the temperature of a kerosene droplet within an enclosed combustion chamber upon ignition, in direct comparison with a contact thermocouple. The instrument demonstrated its capability to measure the droplet’s surface temperature changes throughout its early-stage combustion. Furthermore, the wavelength specificity of the IRT eliminates thermal interference from the subsequent flame, a capability which contact thermocouples lack, thereby enabling measurement of the droplet’s temperature in isolation. This study focuses on single-droplet Jet A kerosene combustion under controlled conditions, using a transferable methodology adaptable to other fuels and environments. It supports the use of IRT for non-contact temperature measurement of fuel droplets and early-stage combustion, aiding fuel characterisation and the development of future fuels such as SAF.