Lei Luo

Dr. Lei Luo

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2022 in IEEE/ACM Transactions on Audio, Speech, and Language Processing
Verified
Journal Article
Closed access
LLLei Luo
Lei Luo
WZWen-Zhao Zhu
Wen-Zhao Zhu
This paper introduces an optimized zero-attractor to improve the performance of least mean square (LMS)-based algorithms for the identification of sparse system. Compared with previous LMS-based algorithms for sparse system identification, the performance of the proposed optimized zero-attracting LMS (OZ-LMS) is much less sensitive to the tuning parameters and measurement noise power, and performs much better for sparse system. Comprehensive performance analysis of the mean-square deviation (MSD) of OZ-LMS is derived in detail. Moreover, the parameter selection rules for optimal steady-state MSD are discussed. Simulation results, using white Gaussian noise and speech input signals, show improved performance over existing methods. Furthermore, we show that the numerical results of OZ-LMS agree with the theoretical predictions.

1 July 2018 in Applied Soft Computing
Verified
Journal Article
Closed access
LLLei Luo
Lei Luo
JSJinwei Sun
Jinwei Sun


16 June 2023 in Actuators
Verified
Journal Article
Open access
PDF file
HLHuijun Liang
Huijun Liang
JLJie Li
Jie Li
YWYongsheng Wang
Yongsheng Wang
MLMingkun Liu
Mingkun Liu
JFJie Fu
Jie Fu
Miao YuMiao Yu
Miao Yu
Single-rod magneto-rheological dampers (MRD) have the advantages of a simple mechanism, high reliability, and broad application range. They are widely used in various semi-active vibration control fields. However, their working mode requires a compensating mechanism to perform volume compensation on the rod, leading to additional stiffness for the system. Ignoring this point makes it tough to establish an accurate mechanical model to describe its performance in the design stage, affecting its application. To address this issue, this study proposes a multi-physics simulation model based on gas compensation for single-rod MRD to characterize their mechanical performance accurately. Firstly, the mechanism and mechanical model of the single-rod gas compensation MRD are introduced. Secondly, considering that its performance is affected by the coupling effect of multiple physical fields, including magnetic, flow, and solid mechanics fields, the control equations and boundary conditions of each field are analyzed separately, and a multi-physics coupling simulation model is established by COMSOL. In particular, the gas compensation unit is considered in the multi-physics simulation model. The effect of the compensating mechanism on the mechanical performance of the damper under different excitation speeds, currents, and initial pressures is analyzed. Finally, the accuracy of the proposed method is verified through the demonstration power test. The results show that the simulation can describe the additional stiffness in the damper. The average error between experimental value and simulation value is 7%. This demonstrates the degree of agreement between the experiment and simulation.

1 August 2016
Verified
Conference Paper
Closed access
DDDung Quoc Duong
Dung Quoc Duong
JSJinwei Sun
Jinwei Sun
TNTuan Phong Nguyen
Tuan Phong Nguyen
LLLei Luo
Lei Luo
This paper presents a novel tuning method for complementary filter exploited for attitude estimation. The complementary filter is the choice of the day in fields where computational simplicity, low power consumption and low cost involved are of prime significance with little interest in the highest degree of accuracy. It is well-known that attitude estimation based on gyroscope measurement alone quickly diverges due to inherent bias issue which is compensated by accelerometer using filtering algorithms. Conventional Complementary Filters (CCF) employed for attitude estimation have fixed filters gain which makes them impassive to the dynamic situation through which the system undergoes, resulting in erroneous estimations in such case. The more complex algorithms have been employed at the cost of computational complexity but are not suitable for most applications based on simple approach and resources. In this paper, Fuzzy Tuned Complementary Filter (FTCF) is proposed to eradicate this issue with the obvious benefit of least computational burden. The proposed algorithm is appraised and validated in conjunction with the well-established Kalman filter using MEMS-based IMU.

30 November 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
JYJinxu Yu
Jinxu Yu
LLLei Luo
Lei Luo
WZWenzhao Zhu
Wenzhao Zhu
YLYongquan Li
Yongquan Li
PXPing Xie
Ping Xie
LZLijie Zhang
Lijie Zhang
Wearing robotic gloves has become increasingly crucial for hand rehabilitation in stroke patients. However, traditional robotic gloves can exert additional pressure on the hand, such as prolonged use leading to poor blood circulation and muscle stiffness. To address these concerns, this work analyzes the finger kinematic model based on computerized tomography (CT) images of human hands, and designs a low-pressure robotic glove that conforms to finger kinematic characteristics. Firstly, physiological data on finger joint flexion and extension were collected through CT scans. The equivalent rotation centers of finger joints were obtained using the SURF and RANSAC algorithms. Furthermore, the trajectory of finger joint end and the correlation equation of finger joint motion were fitted, and a comprehensive finger kinematic model was established. Based on this finger kinematic model, a novel under-actuated exoskeleton mechanism was designed using a human-machine integration approach. The novel robotic glove fully aligns with the equivalent rotation centers and natural motion trajectories of the fingers, exerting minimal and evenly distributed dynamic pressure on the fingers, with a theoretical static pressure value of zero. Experiments involving gripping everyday objects demonstrated that the novel robotic glove significantly reduces the overall pressure on the fingers during grasping compared to the pneumatic glove and the traditional exoskeleton robotic glove. It is suitable for long-term use by stroke patients for rehabilitation training.