Ivo Domagała

Mr. Ivo Domagała

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
MFMarcel Firlej
Marcel Firlej
Katarzyna ZaborowiczKatarzyna Zaborowicz
Katarzyna Zaborowicz
Maciej ZaborowiczMaciej Zaborowicz
Maciej Zaborowicz
EFEwa Firlej
Ewa Firlej
IDIvo Domagała
Ivo Domagała
BBBarbara Danuta Biedziak
Barbara Danuta Biedziak
Orthodontic retention is the final important stage of orthodontic treatment, the aim of which is to consolidate the functional and aesthetic position of teeth. Among adults, fixed retainers made of different types of wires are the most common. The aim of this study was to analyse the mechanical properties of a new generation of fixed orthodontic retainers—printed by 3D printers. Materials and Methods: The study was conducted using samples made of Nextdent MFH C&B N1 resin in the form of cuboid bars with nominal dimensions of width b = 3 mm, thickness d = 0.8 mm; 1 mm; 1.2 mm, length l = 30 mm for each type. The influence of the thickness of the retainers on their strength under loaded conditions was evaluated. Flexural strength, elastic properties, deflection, and creep were compared. The samples were aged in an artificial saliva bath at 37 ± 1 °C during the strength tests. Results: It was shown that differences in the thickness of the samples affected their elastic and strength properties. The highest average flexural modulus, the highest deflection, creep, and strength was characteristic of the samples with the highest thickness (1.2 mm). Samples with an average thickness of 1 mm had the lowest modulus of elasticity. Conclusions: The mechanical properties of 3D printed retainers show that they can be an alternative to metal retainers and the procedure of making new retainers, especially when patients have aesthetic requirements or allergies to metals.

20 August 2021 in Materials
Verified
Journal Article
Open access
PDF file
MFMarcel Firlej
Marcel Firlej
DPDaniel Pieniak
Daniel Pieniak
ANAgata M. Niewczas
Agata M. Niewczas
AWAgata Walczak
Agata Walczak
IDIvo Domagała
Ivo Domagała
BBBarbara Danuta Biedziak
Barbara Danuta Biedziak
With easy-to-process 3D printing materials and fast production, the quality of dental services can be improved. In the conventional procedure, the dentist makes temporary crowns directly in the patient’s mouth, e.g., from the most commonly used bis-acrylic composites. Temporary crowns made directly in the office without the use of CAD/CAM are often of inferior quality, which directly results in impaired hygiene, poorer masticatory mechanics, greater deposition of plaque, calculus and sediment, and may adversely affect periodontal and gum health. The mechanical strength, resistance to aging and abrasion of 3D printing materials are higher than those of the soft materials used in conventional methods. This translates into durability. The patient leaves the surgery with a restoration of higher utility quality compared to the conventional method. The objective of the paper was to determine the influence of aging in artificial saliva of AM (additive manufacturing) orthodontic composites on their functional properties. For the purpose of the study, fillings well-known worldwide were selected. These were traditional UV-curable resins (M I, M II, M III, M V) and a hybrid material based on a UV-curable resin (M VI). Samples were stored in artificial saliva at 37 ± 1 °C in a thermal chamber for 6 months. Indentation hardness, frictional tests and sliding wear measurements were conducted. A comparison between various materials was made. Descriptive statistics, degradation coefficients, H2E, Archard wear and specific wear rate were calculated. The Weibull statistical test for indentation hardness was performed and Hertzian contact stresses for the frictional association were calculated for unaged (M I, M II, M III, M V, M VI) and aged (M I AS, M II AS, M III AS, M V AS, M VI AS) samples. M I exhibited the lowest average hardness among the unaged materials, while M III AS had the lowest average hardness among the aged materials. Comparably low hardness was demonstrated by the M I AS material. The coefficient of friction values for the aged samples were found to be higher. The lowest wear value was demonstrated by the M I material. The wear resistance of most of the tested materials deteriorated after aging. The M VI AS material had the highest increase in wear. According to the results provided, not only the chemical composition and structure, but also aging have a great impact on the indentation hardness and wear resistance of the tested orthodontic materials.

28 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
IDIvo Domagała
Ivo Domagała
Krzysztof PrzystupaKrzysztof Przystupa
Krzysztof Przystupa
MFMarcel Firlej
Marcel Firlej
DPDaniel Pieniak
Daniel Pieniak
LGLeszek Gil
Leszek Gil
MLMariana Levkiv
Mariana Levkiv
Background: Clinical success depends on the contact strength and wear resistance of medical devices made of polymer materials. The scientific goal resulted from the problem of using different methods of surface evaluation of materials used in the production of orthodontic appliances. The purpose of the work was an experimental comparative assessment of indentation hardness and scratch hardness and the sliding wear of four selected polymeric materials used in the manufacture of orthodontic appliances. Methods: Four commercial materials were compared. Shore hardness tests and a scratch test with a Rockwell indenter were performed. A sliding wear test was performed using the ball-on-disc method. Statistical PCA and correlation analyses were performed. Results: The results of scratch hardness measurements using a contact profilometer correlated with the Shore hardness to a greater extent than measurements made using an optical microscope. PCA showed that Shore hardness explains 45% of the total variance in all the results across the materials. Conclusions: The scratch hardness method allows for a more explicit ranking of orthodontic polymeric materials when measurements are made with a profilometer. The ranking of sliding wear resistance should be made separately.

1 December 2020 in Advances in Science and Technology Research Journal
Verified
Journal Article
Open access
IDIvo Domagała
Ivo Domagała
LGLeszek Gil
Leszek Gil
MFMarcel Firlej
Marcel Firlej
DPDaniel Pieniak
Daniel Pieniak
JSJarosław Selech
Jarosław Selech
BBBarbara Danuta Biedziak
Barbara Danuta Biedziak
The paper presents the studies and results of the Shore hardness and scratch test of polymer materials used in medical devices. Polymers of organic PMMA (poly(methyl methacrylate)) origin for the manufacture of orthodontic appliances were tested. Samples of test materials differed in...

7 December 2020 in Materials
Verified
Journal Article
Open access
PDF file
IDIvo Domagała
Ivo Domagała
Krzysztof PrzystupaKrzysztof Przystupa
Krzysztof Przystupa
MFMarcel Firlej
Marcel Firlej
DPDaniel Pieniak
Daniel Pieniak
ANAgata M. Niewczas
Agata M. Niewczas
BBBarbara Danuta Biedziak
Barbara Danuta Biedziak
This paper discusses the issues of strength and creep of polymeric materials used in orthodontic appliances. Orthodontic biomechanics is focused on the movement of individual teeth or dental groups as a result of the force applied by orthodontic appliances. Stresses in the construction of functional and biomechanical appliances is generated when using the apparatus in the oral cavity. The orthodontic appliance must maintain its shape and not be damaged during treatment so strength and creep resistance are fundamental properties. It was assumed that the clinical success of orthodontic appliances can be determined by these performance properties. The aim of the work was the experimental assessment of comparative bending strength and creep resistance of selected popular polymer materials used in the production of biomechanical orthodontic appliances. Four commercial materials manufactured by the world class producers were tested: NextDent Ortho Rigid (Vertex-Dental B.V., Soesterberg, The Netherlands) marked as “1A”; Erkocryl (ERKODENT Erich Kopp GmbH, Pfalzgrafenweiler, Germany)-“2A”; Vertex Orthoplast (Vertex Dental B.V.), blue, marked as “3A” and material with the same name as “3A” but orange, marked in the article as “4A”. All the tests were carried out after aging in artificial saliva for 48 h at a temperature of 37 °C. Flexular strength and flexular modulus were made using the three point bending method according to the ISO 178 technical standard. Creep tests were carried out according to the method contained in ISO 899-2. The creep test was carried out in an artificial saliva bath at 37 °C. The creep tests showed significant differences in the strength, modulus and deformability of the tested materials. The strength reliability of the tested materials also varied. The research shows that the 2A material can be used for orthodontic applications in which long-term stresses should be lower than 20 MPa.

27 May 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
KSKaja Szwarczyńska
Kaja Szwarczyńska
EKEryk Kosmala
Eryk Kosmala
MAMaciej Antczak
Maciej Antczak
IDIvo Domagała
Ivo Domagała
BBBarbara Danuta Biedziak
Barbara Danuta Biedziak
JMJedrzej Musial
Jedrzej Musial
Background/Objectives: Modern artificial intelligence methods are increasingly used in medical and dental image analysis to support diagnosis and treatment planning. In orthodontics, automatic detection of cephalometric landmarks from X-ray images remains a challenging and clinically relevant task. Methods: This study proposes a multi-model approach for cephalometric landmark detection based on the ALD algorithm and three derived models trained with extended image augmentation techniques. The applied augmentations, including contrast and negative transformations, improved the detection of specific anatomical landmarks. The final detection strategy integrates outputs from all four models, selecting the most accurate prediction for each landmark based on historical performance results. Results: The proposed method was evaluated on real datasets. It achieved a mean radial error (MRE) of 2.12 mm compared to 2.26 mm for the baseline model, and a successful detection rate (SDR) of 72.22% within a 2.5 mm threshold compared to 68.87% for the baseline model. Conclusions: The results demonstrate that the ensemble-based approach improves landmark detection accuracy and has the potential to support clinical orthodontic workflows.