Purpose: Real‐time magnetic resonance guided radiation therapy (MRgRT) uses 2D cine imaging for target tracking. This work evaluates the percent image uniformity (PIU) and spatial integrity of cine images in the presence of multileaf collimator (MLC) and gantry motion in order to simulate sliding window and volumetric modulated arc therapy (VMAT) conditions.Methods: Percent image uniformity and spatial integrity of cine images were measured (1) during MLC motion, (2) as a function of static gantry position, and (3) during gantry rotation. PIU was calculated according to the ACR MRI Quality Control Manual. Spatial integrity was evaluated by measuring the geometric distortion of 16 measured marker positions (10 cm or 15.225 cm from isocenter).Results: The PIU of cine images did not vary by more than 1% from static linac conditions during MLC motion and did not vary by more than 3% during gantry rotation. Banding artifacts were present during gantry rotation. The geometric distortion in the cine images was less than 0.88 mm for all points measured throughout MLC motion. For all static gantry positions, the geometric distortion was less than 0.88 mm at 10 cm from isocenter and less than 1.4 mm at 15.225 cm from isocenter. During gantry rotation, the geometric distortion remained less than 0.92 mm at 10 cm from isocenter and less than 1.60 mm at 15.225 cm from isocenter.Conclusion: During MLC motion, cine images maintained adequate PIU, and the geometric distortion of points within 15.225 cm from isocenter was less than the 1 mm threshold necessary for real‐time target tracking and gating. During gantry rotation, PIU was negatively affected by banding artifacts, and spatial integrity was only maintained within 10 cm from isocenter. Future work should investigate the effects imaging artifacts have on real‐time target tracking during MRgRT.
11 June 2025 in Physics and Imaging in Radiation Oncology
This work aims to develop a magnetic resonance (MR)-only treatment planning protocol for integration into magnetic resonance simulation (MR-SIM), on-table treatment planning, and immediate treatment workflow for rapid palliation of painful spine metastases. Thirty-five treatment plans from healthy volunteers were generated on MR-SIM scans using a protocol including: (1) a library of 4 planning target volume (PTV) structures based on vertebral level, (2) default beam templates covering the PTVs while avoiding organs at risk (OAR), (3) bulk density assignments for dose calculations, and (4) a single set of dose optimization parameters. We transferred each plan to the patient’s prior computed tomography simulation (CT-SIM) images and compared dosimetric parameters. A time study was performed on the MR-SIM, on-table planning, and immediate treatment workflow for all 35 cases using healthy volunteers. All bulk density MR-SIM plans resulted in acceptable dose distributions, with 100 % deemed appropriate for treatment by two physicians. The maximum point dose was within 3.2 %, and the minimum dose to 90 % of the target volume was within 2.8 % of the prescription dose. The time study demonstrated that the proposed workflow could be completed in a mean time of 23.6 min for the 3 Gy (10 fractions) plan and 25.4 min for the 8 Gy (single fraction) plan, from patient placement to treatment completion. These results demonstrate that safe, fast palliation of spine metastases can be achieved in under 30 min using MR-SIM, bulk density on-table planning, and immediate treatment delivery.