Justin Rineer

Justin Rineer


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Radiotherapy and Oncology
Verified
Journal Article
Open access
JEJaden D. Evans
Jaden D. Evans
DGDaniel R. Gomez
Daniel R. Gomez
AAArya Amini
Arya Amini
NRNeal Rebueno
Neal Rebueno
PAPamela K. Allen
Pamela K. Allen
JWJames W. Welsh
James W. Welsh
Improved radiation delivery and planning has allowed, in some instances, for the retreatment of thoracic tumors. We investigated the dose limits of the aorta wherein grade 5 aortic toxicity was observed after reirradiation of lung tumors. In a retrospective analysis, 35 patients were identified, between 1993 and 2008, who received two rounds of external beam irradiation that included the aorta in the radiation fields of both the initial and retreatment plans. We determined the maximum cumulative dose to 1 cm(3) of the aorta (the composite dose) for each patient, normalized these doses to 1.8 Gy/fraction, and corrected them for long-term tissue recovery between treatments (NIDR). The median time interval between treatments was 30 months (range, 1-185 months). The median follow-up of patients alive at analysis was 42 months (range, 14-70 months). Two of the 35 patients (6%) were identified as having grade 5 aortic toxicities. There was a 25% rate of grade 5 aortic toxicity for patients receiving composite doses ≥120.0 Gy (vs. 0% for patients receiving <120.0 Gy) (P=0.047). Grade 5 aortic toxicities were observed with composite doses ≥120.0 Gy (NIDR ≥90.0 Gy) to 1cm(3) of the aorta.

1 September 2020 in Practical Radiation Oncology
Verified
Journal Article
Closed access
GGGordon Glober
Gordon Glober
AKAlex Kubli
Alex Kubli
JKJerrold E Kielbasa
Jerrold E Kielbasa
BCBhavin Chauhan
Bhavin Chauhan
DBDouglas Burch
Douglas Burch
PKPatrick Kelly
Patrick Kelly

23 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JRJacob Ricci
Jacob Ricci
JRJustin Rineer
Justin Rineer
ASAmish P. Shah
Amish P. Shah
SMSanford L. Meeks
Sanford L. Meeks
PKPatrick Kelly
Patrick Kelly
With the implementation of MR-LINACs, real-time adaptive radiotherapy has become a possibility within the clinic. However, the process of adapting a patient’s plan is time consuming and often requires input from the entire clinical team, which translates to decreased throughput and limited patient access. In this study, the authors propose and simulate a workflow to address these inefficiencies in staffing and patient throughput. Two physicians, three radiation therapists (RTT), and a research fellow each adapted bladder and bowel contours for 20 fractions from 10 representative patient plans. Contouring ability was compared via calculation of a Dice Similarity Index (DSI). The DSI for bladder and bowel based on each potential physician–therapist pair, as well as an inter-physician comparison, exhibited good overlap amongst all comparisons (p = 0.868). Plan quality was compared through calculation of the conformity index (CI), as well as an evaluation of the plan’s dose to a ‘gold standard’ set of structures. Overall, non-physician plans passed 91.2% of the time. Of the eight non-physician plans that failed their clinical evaluation, six also failed their evaluation against the ‘gold standard’. Another two plans that passed their clinical evaluation subsequently failed in their evaluation against the ‘gold standard’. Thus, the PF-ROAR process has a success rate of 97.5%, with 78/80 plans correctly adapted to the gold standard or halted at treatment. These findings suggest that a physician-free workflow can be well tolerated provided RTTs continue to develop knowledge of MR anatomy and careful attention is given to understanding the complexity of the plan prior to treatment.

5 February 2014 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
BWBenjamin J Waghorn
Benjamin J Waghorn
ASAmish P Shah
Amish P Shah
JRJustin Rineer
Justin Rineer
KLKatja M Langen
Katja M Langen
SMSanford L Meeks
Sanford L Meeks
Purpose: Intrafraction motion during step-and-shoot (SNS) IMRT is known to affect the target dosimetry by a combination of dose blurring and interplay effects. These effects are typically managed by adding a margin around the target. A quantitative analysis was performed, assessing the relationship between target motion, margin size, and target dosimetry with the goal of introducing new margin recipes. Methods: A computational algorithm was used to calculate 1,174 motion-encoded dose distributions and DVHs within the patient’s CT dataset. Sinusoidal motion tracks were used simulating intrafraction motion for nine lung tumor patients, each with multiple margin sizes. Results: D95% decreased by less than 3% when the maximum target displacement beyond the margin experienced motion less than 5 mm in the superior-inferior direction and 15 mm in the anterior-posterior direction. For target displacements greater than this, D95% decreased rapidly. Conclusions: Targets moving in excess of 5 mm outside the margin can cause significant changes to the target. D95% decreased by up to 20% with target motion 10 mm outside the margin, with underdosing primarily limited to the target periphery. Multi-fractionated treatments were found to exacerbate target under-coverage. Margins several millimeters smaller than the maximum target displacement provided acceptable motion protection, while also allowing for reduced normal tissue morbidity. PACS: 87.55.dk

4 May 2023 in arXiv
Verified
Preprint
Open access
PDF file
IIIlkin Isler
Ilkin Isler
Debesh JhaDebesh Jha
Debesh Jha
CLCurtis Lisle
Curtis Lisle
JRJustin Rineer
Justin Rineer
PKPatrick Kelly
Patrick Kelly
UBUlas Bagci
Ulas Bagci
In this study, our goal is to show the impact of self-supervised pre-training of transformers for organ at risk (OAR) and tumor segmentation as compared to costly fully-supervised learning. The proposed algorithm is called Monte Carlo Transformer based U-Net (MC-Swin-U). Unlike many other available models, our approach presents uncertainty quantification with Monte Carlo dropout strategy while generating its voxel-wise prediction. We test and validate the proposed model on both public and one private datasets and evaluate the gross tumor volume (GTV) as well as nearby risky organs' boundaries. We show that self-supervised pre-training approach improves the segmentation scores significantly while providing additional benefits for avoiding large-scale annotation costs.

11 June 2025 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
JKJerrold E Kielbasa
Jerrold E Kielbasa
LKLogan Kimble
Logan Kimble
JRJustin Rineer
Justin Rineer
CSCameron W. Swanick
Cameron W. Swanick
PKPatrick Kelly
Patrick Kelly
ASAmish P. Shah
Amish P. Shah
This work aims to develop a magnetic resonance (MR)-only treatment planning protocol for integration into magnetic resonance simulation (MR-SIM), on-table treatment planning, and immediate treatment workflow for rapid palliation of painful spine metastases. Thirty-five treatment plans from healthy volunteers were generated on MR-SIM scans using a protocol including: (1) a library of 4 planning target volume (PTV) structures based on vertebral level, (2) default beam templates covering the PTVs while avoiding organs at risk (OAR), (3) bulk density assignments for dose calculations, and (4) a single set of dose optimization parameters. We transferred each plan to the patient’s prior computed tomography simulation (CT-SIM) images and compared dosimetric parameters. A time study was performed on the MR-SIM, on-table planning, and immediate treatment workflow for all 35 cases using healthy volunteers. All bulk density MR-SIM plans resulted in acceptable dose distributions, with 100 % deemed appropriate for treatment by two physicians. The maximum point dose was within 3.2 %, and the minimum dose to 90 % of the target volume was within 2.8 % of the prescription dose. The time study demonstrated that the proposed workflow could be completed in a mean time of 23.6 min for the 3 Gy (10 fractions) plan and 25.4 min for the 8 Gy (single fraction) plan, from patient placement to treatment completion. These results demonstrate that safe, fast palliation of spine metastases can be achieved in under 30 min using MR-SIM, bulk density on-table planning, and immediate treatment delivery.