Andrew Cameron

Mr. Andrew Cameron

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Jarred William Fastier-WoollerJarred William Fastier-Wooller
Jarred William Fastier-Wooller
Hoang-Phuong PhanHoang-Phuong Phan
Hoang-Phuong Phan
Toan DinhToan Dinh
Toan Dinh
TNTuan-Khoa Nguyen
Tuan-Khoa Nguyen
ACAndrew Cameron
Andrew Cameron
Dzung DaoDzung Dao
Dzung Dao
This paper presents the design and development of a low cost and reliable maximal voluntary bite force sensor which can be manufactured in-house by using an acrylic laser cutting machine. The sensor has been designed for ease of fabrication, assembly, calibration, and safe use. The sensor is capable of use within an hour of commencing production, allowing for rapid prototyping/modifications and practical implementation. The measured data shows a good linear relationship between the applied force and the electrical resistance of the sensor. The output signal has low drift, excellent repeatability, and a large measurable range of 0 to 700 N. A high signal-to-noise response to human bite forces was observed, indicating the high potential of the proposed sensor for human bite force measurement.

15 March 2024 in Journal of Dentistry
Verified
Journal Article
Open access
ACAndrew Cameron
Andrew Cameron
JCJoanne Jung Eun Choi
Joanne Jung Eun Choi
AIAndrew Ip
Andrew Ip
NLNathan Lyons
Nathan Lyons
NYNavodika Yaparathna
Navodika Yaparathna
SFStefanie Feih
Stefanie Feih
This study endeavours to investigate the effect of printing orientation on the trueness of additively manufactured molar zirconia crowns. The areal surface roughness and the characteristics of the marginal regions of the crowns were also considered. Twelve molar crowns were manufactured at 0°, 45°, and, 90° printing orientations in a Lithoz and AON zirconia printer, respectively. Twelve milled crowns were used as a comparison. Samples were scanned and analysed in metrology software to determine the trueness of the groups. Regions of interest were defined as the margins, intaglio surface and contact points. Areal surface roughness and print layer thickness were further analysed using a confocal laser scanning microscope. The results indicate that there are clear differences between the investigated desktop (AON) and industrial (Lithoz) 3D printer. The 45° Lithoz group is the only sample group showing no significantly different results in trueness for all regions analysed compared to the milled group. Areal surface roughness analysis indicates that the print layers in the marginal regions are within clinically tolerable limits and surface characteristics. The printing orientation for zirconia crowns is critical to trueness, and differences are evident between different AM apparatuses. Considerations for design and orientation between different apparatuses should therefore be considered when utilising direct additive manufacturing processes. The areal surface roughness of the marginal regions is within acceptable clinical limits for all manufacturing processes and print orientations considered. The materials and apparatuses for additive manufacturing of zirconia crowns are now clinically acceptable from the perspective of the trueness of a final crown for critical functional surfaces and areal surface roughness of the marginal regions.

1 March 2024 in Journal of Dentistry
Verified
Journal Article
Open access
ZKZei Kagaoan
Zei Kagaoan
XLXiaoyun Liu
Xiaoyun Liu
ACAndrew Cameron
Andrew Cameron
JAJohn Aarts
John Aarts
JCJoanne Choi
Joanne Choi
The purpose of this systematic review was to investigate how different interventions can impact the bond strength of additively manufactured crown materials after cementation. Four online databases Ovid MEDLINE, Scopus, Web of Science and Google Scholar were searched up to January 2023. Inclusion criteria were English-language publications, full-text, and in vitro studies only. Exclusion criteria were studies that did not assess the bonding of an additively manufactured crown material to cement or did not conduct any bond strength tests. An assessment of risk of bias was done in accordance with a modified Consolidated Standards of Reporting Trials (CONSORT) checklist. Each study was analysed and compared based on the interventions and bond strength results. Six studies satisfied the inclusion and exclusion criteria, five of which evaluated photopolymerised resin and one that tested zirconia manufacturing via 3D printing. All studies observed a low risk of bias. The interventions applied included the type of surface pretreatments, airborne-particle abrasion pressure, cement type, taper of crown, and artificial aging. Three studies compared the bonding performance to milled materials. The bond strength of crown materials additively manufactured from photopolymers presented high values and are comparable to milled materials. The systematic review demonstrated there was no definite superior cement type, but airborne-particle abrasion with alumina was generally recommended. There is a clear gap in the literature regarding the bond strength of additively manufactured crowns. Therefore, further research is necessary to evaluate its clinical applicability for permanent restorations. Factors influencing the bond strength of additively manufactured crown materials should be evaluated so dental professionals can adopt procedures that promote the strongest bond.

1 January 2023 in Journal of Oral Science
Verified
Journal Article
Open access
PDF file
ACAndrew Cameron
Andrew Cameron
KTKeith Tong
Keith Tong
STSantosh Tadakamadla
Santosh Tadakamadla
JEJane L. Evans
Jane L. Evans
MAMenaka Abuzar
Menaka Abuzar
Purpose: Scientific evidence pertaining to the evaluation of trueness of occlusal splints fabricated using different three-dimensional (3D) printers and build orientations compared to subtractive technologies is lacking.Methods: Overall, one hundred and ten occlusal splints were manufactured using two different 3D printers and a dental mill. Five groups of ten were fabricated using the 3D printers at different build orientations (0, 30, 45, 60, and 90 degrees). In addition, a comparison group of ten occlusal splints was subtractively manufactured using a five-axis dental mill. All occlusal splints were scanned and exported as a standard tessellation language file. Analysis was conducted with metrology software with root mean square estimate average positive deviation and average negative deviation used as the measured outcome.Results: The 0 degree printing orientation was the most accurate for printer one with the root mean square value of 0.05 ± 0.01 mm, and 60 degree printing orientation was most accurate for printer two with the RMS value of 0.11 ± 0.01 mm. Subtractively manufactured occlusal splint had significantly higher trueness with the lowest RMS value of 0.03 ± 0.05 mm.Conclusion: Build orientations influence the trueness of additively manufactured occlusal splints while occlusal splints produced by subtractive manufacturing were statistically significantly more accurate.

5 March 2022 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
ACAndrew Cameron
Andrew Cameron
JEJane L. Evans
Jane L. Evans
MAMenaka Abuzar
Menaka Abuzar
STSantosh Kumar Tadakamadla
Santosh Kumar Tadakamadla
Robert LoveRobert Love
Robert Love

Verified
Journal Article
Open access
PDF file
SPSomayeh Parvizi
Somayeh Parvizi
ACAndrew Cameron
Andrew Cameron
STSantosh K. Tadakamadla
Santosh K. Tadakamadla
Carlos Marcelo FigueredoCarlos Marcelo Figueredo
Carlos Marcelo Figueredo
Peter ReherPeter Reher
Peter Reher
The purpose of this in vitro study is to evaluate the effectiveness of incorporating a new irrigation system into a surgical guide and monitor its effect on heat generation during implant bed preparation. A total of 48 surgically guided osteotomies were performed on 12 bovine ribs divided into 4 groups, using different irrigation techniques: Group A (test) had entry and exit channels incorporated into the guide; Group B had a similar design with an entry channel only; Group C had conventional external irrigation; and Group D (control) had no irrigation. Heat generation during the osteotomies was measured using thermocouples placed at a depth of 2 mm and 6 mm. The lowest mean temperature was observed in Group A (22.1 °C at 2 mm and 21.4 °C at 6 mm), which was statistically significant when compared with Groups C and D (p < 0.001). Group A showed a lower mean temperature compared with Group B as well; however, it was statistically significant only at 6 mm depth (p < 0.05). In conclusion, the proposed surgical guide has significantly reduced heat generation during implant osteotomy compared to conventional external irrigation. The integration of an exit cooling channel can resolve limitations found in previously designed surgical guides such as debris blockage and can be easily incorporated into computer designing and 3D printing software.