CRCristina Rodriguez-Gil
Cristina Rodriguez-Gil
The WHO Consensus Document on the epidemiology of the SARS epidemic in 2003, included a report on a concentrated outbreak in one Hong Kong housing block which was considered a ‘super-spreading event’. The WHO report conjectured that the sanitary plumbing system was one transmission route for the virus. Empty U-traps allowed the aerosolised virus to enter households from the sewerage system. No biological evidence was presented. This research reports evidence that pathogens can be aerosolised and transported on airstreams within sanitary plumbing systems and enter buildings via empty U-traps. A sanitary plumbing system was built, representing two floors of a building, with simulated toilet flushes on the lower floor and a sterile chamber with extractor fan on the floor above. Cultures of a model organism, Pseudomonas putida at 106–109 cfu ml-1 in 0·85% NaCl were flushed into the system in volumes of 6 to 20 litres to represent single or multiple toilet flushes. Air and surface samples were cultured on agar plates and assessed qualitatively and semi-quantitatively. Flushing from a toilet into a sanitary plumbing system generated enough turbulence to aerosolise pathogens. Typical sanitary plumbing system airflows (between 20–30 ls-1) were sufficient to carry aerosolised pathogens between different floors of a building. Empty U-traps allowed aerosolised pathogens to enter the chamber, encouraging cross-transmission. All parts of the system were found to be contaminated post-flush. Empty U-traps have been observed in many buildings and a risk assessment indicates the potential for high risk cross-transmission under defect conditions in buildings with high pathogen loading such as hospitals. Under defective conditions (which are not uncommon) aerosolised pathogens can be carried on the airflows within sanitary plumbing systems. Our findings show that greater consideration should be given to this mode of pathogen transmission.

10 February 2021 in Indoor Air
Verified
Journal Article
Open access
PDF file
Michael GormleyMichael Gormley
Michael Gormley
TAThomas Aspray
Thomas Aspray
DKDavid Kelly
David Kelly
Aerosols are readily transported on airstreams through building sanitary plumbing and sewer systems, and those containing microbial pathogens (known as bioaerosols) are recognized as contributors to infection spread within buildings. When a defect occurs in the sanitary plumbing system that affects the system integrity, a cross‐transmission route is created that can enable the emission of bioaerosols from the system into the building. These emission occurrences are characterized as short‐burst events (typically 99.5%) were 11 μm anywhere in the system. Particle count was influenced by toilet flush volume, but it was not possible to determine if there was any direct influence from airflow rate since both particle and biological data showed no correlation with upward airflow rates and velocities. Typical emissions resulting from a 6 L toilet flush were in the range of 280–400 particles per second at a concentration of typically 9–12 number per cm3 and a total particle count in the region of 3000 to 4000 particles, whereas the peak emissions from a 1.2 L toilet flush were 60–80 particles per second at a concentration of 2.4–3 number per cm3 and a total particle count in the region of 886 to 1045 particles. The reduction in particles is in direct proportion to the reduction in toilet flush volume. The slit‐to‐agar sampler was able to provide viable time course CFU data and confirmed the origin of the particles to be the tracer microorganism flushed into the system. The time course data also have characteristics consistent with the unsteady nature of a toilet flush.

1 November 2022 in Water
Verified
Journal Article
Open access
PDF file
MGMichael Gormley
Michael Gormley
CSColin Stewart
Colin Stewart
DKDavid Kelly
David Kelly
DCDavid Campbell
David Campbell
Michael GormleyMichael Gormley
Michael Gormley
Two-phase annular flow in vertical pipes is one of the most common and important flow regimes in fluid mechanics, particularly in the field of building drainage systems where discharges to the vertical pipe are random and the flow is unsteady. With the development of experimental techniques and analytical methods, the understanding of the fundamental mechanism of the annular two-phase flow has been significantly advanced, such as liquid film development, evolution of the disturbance wave, and droplet entrainment mechanism. Despite the hundreds of papers published so far, the mechanism of annular flow remains incompletely understood. Therefore, this paper summarizes the research on two-phase annular flow in vertical pipes mainly in the last two decades. The review is mainly divided into two parts, i.e., the investigation methodologies and the advancement of knowledge. Different experimental techniques and numerical simulations are compared to highlight their advantages and challenges. Advanced underpinning physics of the mechanism is summarized in several groups including the wavy liquid film, droplet behaviour, entrainment and void fraction. Challenges and recommendations are summarized based on the literature cited in this review.

19 June 2013 in Building Services Engineering Research & Technology
Verified
Journal Article
Closed access
PDF file
Michael GormleyMichael Gormley
Michael Gormley
KTKe Templeton
Ke Templeton
DKDA Kelly
DA Kelly
AHA Hardie
A Hardie
A potential cross-transmission route, first identified in the spread of the SARs virus in South East Asia, in which infection was spread by virus-laden aerosolised droplets entering habitable space via defective water traps is investigated. The main aim of this work was to detect norovirus in wastewater from the collection drain in a hospital Building Drainage System and attempt to trace it in the BDS vent airflow. The methodology employed polymerase chain reaction tests on waste water samples and indicated strong positives for the norovirus GII strain from the collection drain, corresponding to an outbreak in the building, confirming that the BDS is contaminated in such circumstances and poses a threat. Pathogens were not detected in the BDS vertical stack airflows; however, the methodology employed to collect samples from the airflow was considered ineffective requiring further research. An average temperature of 24.3℃ was recorded, together with an average humidity of 96.6%. This research also confirmed that inside the building drainage stack, air flow movement occurs in both the ‘up’ and ‘down’ direction. Thus, aerosolised pathogens could travel from the contaminated horizontal collection drains upwards and enter wards via defective traps or little used showers, sinks, baths and sluices.

9 September 2011 in Building Services Engineering Research & Technology
Verified
Journal Article
Closed access
PDF file
Michael GormleyMichael Gormley
Michael Gormley
JSJa Swaffield
Ja Swaffield
PSPa Sleigh
Pa Sleigh
CNCj Noakes
Cj Noakes
The outbreak of severe acute respiratory syndrome (SARS), centred on Southeast Asia in 2002 and 2003, sparked fears of an uncontrollable pandemic. The outbreak at one housing complex in Hong Kong resulted in a disproportionately large number of cases with 321 people contracting the virus, resulting in 42 fatalities. This outbreak led to an investigation by World Health Organisation, which firmly laid the blame for the spread of the virus in the housing complex on defects in the building drainage and vent system. The mode of viral transmission was identified as due to airborne aerosolised particles from virus-laden excreta emanating from the drainage system. The aerosolised particles were allowed to enter the habitable space through empty water trap seals which are the main protection against such ingress in a building drainage and vent system. This research reports on the defective trap identification system developed to provide a means of testing the seal afforded by the water trap seal inbuildings. This innovative sonar-like technology incorporates a means of identifying compromised water trap seals anywhere in a building in a repeatable, non-destructive manner. While the technology has been effectively validated by a combination of laboratory investigation, site testing and numerical simulation, the rationale for the need to monitor water trap seals is less obvious to professionals operating in this field. This article addresses this issue and presents such a rationale, identifying some of the harmful pathogens which could lead to cross-contamination from person to person via the building drainage system. Practical applications: The research carried out in this area has highlighted the lack of any real monitoring of water trap seal status in buildings and has put the issue firmly on the agenda for consideration by building owners, operators and regulators, for whom the building drainage and vent system has long been categorised as ‘fit and forget’. The inspiration for this study was the response to the SARS outbreak which began in 2002. The case to monitor this important seal is clearly made and whilst the predicted pandemic of the SARS virus failed to materialise on an extended time frame and the outbreak has largely been consigned to history, it should serve as a constant reminder to professionals in the industry that we ‘fit and forget’ at our peril.