The WHO Consensus Document on the epidemiology of the SARS epidemic in 2003, included a report on a concentrated outbreak in one Hong Kong housing block which was considered a ‘super-spreading event’. The WHO report conjectured that the sanitary plumbing system was one transmission route for the virus. Empty U-traps allowed the aerosolised virus to enter households from the sewerage system. No biological evidence was presented. This research reports evidence that pathogens can be aerosolised and transported on airstreams within sanitary plumbing systems and enter buildings via empty U-traps. A sanitary plumbing system was built, representing two floors of a building, with simulated toilet flushes on the lower floor and a sterile chamber with extractor fan on the floor above. Cultures of a model organism, Pseudomonas putida at 106–109 cfu ml-1 in 0·85% NaCl were flushed into the system in volumes of 6 to 20 litres to represent single or multiple toilet flushes. Air and surface samples were cultured on agar plates and assessed qualitatively and semi-quantitatively. Flushing from a toilet into a sanitary plumbing system generated enough turbulence to aerosolise pathogens. Typical sanitary plumbing system airflows (between 20–30 ls-1) were sufficient to carry aerosolised pathogens between different floors of a building. Empty U-traps allowed aerosolised pathogens to enter the chamber, encouraging cross-transmission. All parts of the system were found to be contaminated post-flush. Empty U-traps have been observed in many buildings and a risk assessment indicates the potential for high risk cross-transmission under defect conditions in buildings with high pathogen loading such as hospitals. Under defective conditions (which are not uncommon) aerosolised pathogens can be carried on the airflows within sanitary plumbing systems. Our findings show that greater consideration should be given to this mode of pathogen transmission.
Aerosols are readily transported on airstreams through building sanitary plumbing and sewer systems, and those containing microbial pathogens (known as bioaerosols) are recognized as contributors to infection spread within buildings. When a defect occurs in the sanitary plumbing system that affects the system integrity, a cross‐transmission route is created that can enable the emission of bioaerosols from the system into the building. These emission occurrences are characterized as short‐burst events (typically 99.5%) were 11 μm anywhere in the system. Particle count was influenced by toilet flush volume, but it was not possible to determine if there was any direct influence from airflow rate since both particle and biological data showed no correlation with upward airflow rates and velocities. Typical emissions resulting from a 6 L toilet flush were in the range of 280–400 particles per second at a concentration of typically 9–12 number per cm3 and a total particle count in the region of 3000 to 4000 particles, whereas the peak emissions from a 1.2 L toilet flush were 60–80 particles per second at a concentration of 2.4–3 number per cm3 and a total particle count in the region of 886 to 1045 particles. The reduction in particles is in direct proportion to the reduction in toilet flush volume. The slit‐to‐agar sampler was able to provide viable time course CFU data and confirmed the origin of the particles to be the tracer microorganism flushed into the system. The time course data also have characteristics consistent with the unsteady nature of a toilet flush.
Two-phase annular flow in vertical pipes is one of the most common and important flow regimes in fluid mechanics, particularly in the field of building drainage systems where discharges to the vertical pipe are random and the flow is unsteady. With the development of experimental techniques and analytical methods, the understanding of the fundamental mechanism of the annular two-phase flow has been significantly advanced, such as liquid film development, evolution of the disturbance wave, and droplet entrainment mechanism. Despite the hundreds of papers published so far, the mechanism of annular flow remains incompletely understood. Therefore, this paper summarizes the research on two-phase annular flow in vertical pipes mainly in the last two decades. The review is mainly divided into two parts, i.e., the investigation methodologies and the advancement of knowledge. Different experimental techniques and numerical simulations are compared to highlight their advantages and challenges. Advanced underpinning physics of the mechanism is summarized in several groups including the wavy liquid film, droplet behaviour, entrainment and void fraction. Challenges and recommendations are summarized based on the literature cited in this review.
12 February 2016 in Journal of Flood Risk Management
The main pond within the historic Royal Botanic Garden Edinburgh is an important component of urban blue-green infrastructure. This paper reports on flood resilience provided by the pond (simulated using the CityCAT hydrodynamic model), its water residence times (obtained using the Shetran hydrological model), and the ecology and biodiversity (vascular plants, bryophytes, aquatic invertebrates, phyto- and zooplankton, birds) of the pond and the adjacent area. The results show that the pond improves the flood resilience with at least a 27% reduction in the peak discharge during a 1 h, one in 100-year event. The area represents a biodiversity hot spot with a range of native taxa occurring among introduced plant species. The plankton community is dominated by diatoms, reflecting elevated levels of turbulence and a relatively short residence time, with an average value of 10 days. Analysis of macroinvertebrate community indicates a potential for water quality improvement. The results are discussed in relation to multiple societal benefits related to flood resilience, recreation, education, water quality, amenity and biodiversity value. The conclusions may prove particularly valuable for introducing practical measures in the water catchment, preventing waterlogging of the soil and ensuring an uninterrupted supply of public services. This article is part of the theme issue ‘Urban flood resilience'.