Harjit Singh

Prof. Harjit Singh

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2011 in Applied Energy
Verified
Journal Article
Closed access
MAM. Alam
M. Alam
Harjit SinghHarjit Singh
Harjit Singh
MLM.C. Limbachiya
M.C. Limbachiya

1 August 2012 in Journal of Nanotechnology in Engineering and Medicine
Verified
Journal Article
Closed access
PDF file
VKVikrant Khullar
Vikrant Khullar
HTHimanshu Tyagi
Himanshu Tyagi
PPPatrick Phelan
Patrick Phelan
TOTodd P. Otanicar
Todd P. Otanicar
Harjit SinghHarjit Singh
Harjit Singh
RTRobert A. Taylor
Robert A. Taylor

1 February 2017 in Applied Energy
Verified
Journal Article
Open access
MAM. Alam
M. Alam
Harjit SinghHarjit Singh
Harjit Singh
SSSuresh Sivan
Suresh Sivan
DRD.A.G. Redpath
D.A.G. Redpath
The potential savings in space heating energy from the installation of Fumed Silica (FS) and Glass Fibre (GF) Vacuum Insulation Panels (VIPs) were compared to conventional expanded polystyrene (EPS) insulation for three different non-domestic buildings situated in London (UK). A discounted payback period analysis was used to determine the time taken for the capital cost of installing the insulation to be recovered. VIP materials were ranked using cost and density indexes. The methodology of the Payback analysis carried out considered the time dependency of VIP thermal performance, fuel prices and rental income from buildings. These calculations show that VIP insulation reduced the annual space heating energy demand and carbon dioxide (CO2) emissions by approximately 10.2%, 41.3% and 26.7% for a six storey office building, a two floor retail unit building and a four storey office building respectively. FS VIPs had the shortest payback period among the insulation materials studied, ranging from 2.5 years to 17 years, depending upon the rental income of the building. For GF VIPs the calculated payback period was considerably longer and in the case of the typical 4 storey office building studied its cost could not be recovered over the life time of the building. For EPS insulation the calculated payback period was longer than its useful life time for all three buildings. FS VIPs were found to be economically viable for installation onto non-domestic buildings in high rental value locations assuming a lifespan of up to 60 years

1 January 2017 in Applied Thermal Engineering
Verified
Journal Article
Closed access
DSD.K. Singh
D.K. Singh
SSSuresh Sivan
Suresh Sivan
Harjit SinghHarjit Singh
Harjit Singh
BRB.A.J. Rose
B.A.J. Rose
STSavvas Tassou
Savvas Tassou
NAN. Anantharaman
N. Anantharaman


1 April 2010 in Renewable Energy
Verified
Journal Article
Closed access
Harjit SinghHarjit Singh
Harjit Singh
AMA. Muetze
A. Muetze
PEP.C. Eames
P.C. Eames