Nico van Bakelen

Dr. Nico van Bakelen

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2012 in Journal of Dental Research
Verified
Journal Article
Closed access
PDF file
GBG.J. Buijs
G.J. Buijs
NBNico van Bakelen
Nico van Bakelen
JJJ. Jansma
J. Jansma
JVJ.G.A.M. de Visscher
J.G.A.M. de Visscher
THT.J.M. Hoppenreijs
T.J.M. Hoppenreijs
RBR.R.M. Bos
R.R.M. Bos
Biodegradable fixation systems could reduce or delete the problems associated with metallic systems, since removal is not necessary. The aim of this study was to establish the effectiveness and safety of biodegradable plates and screws as potential alternatives to metallic ones. This multi-center randomized controlled trial was conducted from December 2006 to July 2009. Included were patients who underwent mandibular and/or Le Fort I osteotomies and those with fractures of the mandible, maxilla, and zygoma. The patients were assigned to a titanium control group (KLS Martin) or to a biodegradable test group (Inion CPS). The primary outcome measure was ‘bone healing 8 weeks post-operatively’. The Intention-To-Treat (ITT) analysis of 113 patients in the titanium group and 117 patients in the biodegradable group yielded a significant difference (p < 0.001), primarily because in 25 patients (21%) who were randomized to the biodegradable group, the surgeon made the decision to switch to titanium intra-operatively. Despite this ‘inferior’ primary outcome result, biodegradable plates and screws could be safely used when it was possible to apply them. The benefits of using biodegradable systems (fewer plate removal operations) should be confirmed during a follow-up of minimally 5 years ( Controlled-trials.com ISRCTN number 44212338).

15 October 2013 in Journal of Dental Research
Verified
Journal Article
Closed access
NBNico van Bakelen
Nico van Bakelen
GBG.J. Buijs
G.J. Buijs
JJJ. Jansma
J. Jansma
JVJ.G.A.M. de Visscher
J.G.A.M. de Visscher
THTh.J.M. Hoppenreijs
Th.J.M. Hoppenreijs
RBR.R.M. Bos
R.R.M. Bos
Biodegradable osteosynthesis could reduce/delete the problems associated with titanium plate removal. The aim of the present study was to compare the clinical performance in the first 2 post-operative years between a biodegradable and a titanium system in oral and maxillofacial surgery. The multicenter randomized controlled trial (RCT) was performed in the Netherlands from December 2006 to July 2009. Included were 230 patients who underwent a bilateral sagittal split osteotomy (BSSO) and/or a Le Fort-I osteotomy and those treated for fractures of the mandible, maxilla, or zygoma. The patients were randomly assigned to a titanium group (KLS Martin) or to a biodegradable group (Inion CPS). Plate removal was necessary in 16 of the 134 patients (11.9%) treated with titanium and in 21 of the 87 patients (24.1%) treated with the biodegradable system within the first 2 post-operative years [p = .016, HR biodegradable (95% CI) = 2.2 (1.1-4.2), HR titanium = 1]. Occlusion, VAS, and MFIQ scores showed that both groups had good mandibular function and were (almost) free of pain 1 and 2 years post-operatively (http://controlled-trials.com ISRCTN 44212338).

7 July 2022 in Polymers
Verified
Journal Article
Open access
PDF file
BGBarzi Gareb
Barzi Gareb
NBNico van Bakelen
Nico van Bakelen
Arjan VissinkArjan Vissink
Arjan Vissink
RBRuud R. M. Bos
Ruud R. M. Bos
BMBaucke Van Minnen
Baucke Van Minnen
Osteosynthesis systems are used to fixate bone segments in maxillofacial surgery. Titanium osteosynthesis systems are currently the gold standard. However, the disadvantages result in symptomatic removal in up to 40% of cases. Biodegradable osteosynthesis systems, composed of degradable polymers, could reduce the need for removal of osteosynthesis systems while avoiding the aforementioned disadvantages of titanium osteosyntheses. However, disadvantages of biodegradable systems include decreased mechanical properties and possible foreign body reactions. In this review, the literature that focused on the in vitro and in vivo performances of biodegradable and titanium osteosyntheses is discussed. The focus was on factors underlying the favorable clinical outcome of osteosyntheses, including the degradation characteristics of biodegradable osteosyntheses and the host response they elicit. Furthermore, recommendations for clinical usage and future research are given. Based on the available (clinical) evidence, biodegradable copolymeric osteosyntheses are a viable alternative to titanium osteosyntheses when applied to treat maxillofacial trauma, with similar efficacy and significantly lower symptomatic osteosynthesis removal. For orthognathic surgery, biodegradable copolymeric osteosyntheses are a valid alternative to titanium osteosyntheses, but a longer operation time is needed. An osteosynthesis system composed of an amorphous copolymer, preferably using ultrasound welding with well-contoured shapes and sufficient mechanical properties, has the greatest potential as a biocompatible biodegradable copolymeric osteosynthesis system. Future research should focus on surface modifications (e.g., nanogel coatings) and novel biodegradable materials (e.g., magnesium alloys and silk) to address the disadvantages of current osteosynthesis systems.

1 July 2014 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
NBNico van Bakelen
Nico van Bakelen
GBG.J. Buijs
G.J. Buijs
JJJ. Jansma
J. Jansma
JVJ.G.A.M. de Visscher
J.G.A.M. de Visscher
THTh.J.M. Hoppenreijs
Th.J.M. Hoppenreijs
RBR.R.M. Bos
R.R.M. Bos

20 July 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NBNico van Bakelen
Nico van Bakelen
KVK. M. Vermeulen
K. M. Vermeulen
GBG. J. Buijs
G. J. Buijs
JJJ. Jansma
J. Jansma
JVJ. G. A. M. de Visscher
J. G. A. M. de Visscher
RBR. R. M. Bos
R. R. M. Bos
Biodegradable fixation systems could reduce/delete the problems associated with titanium plate removal. This means less surgical discomfort, and a reduction in costs. The aim of the present study was to compare the cost-effectiveness between a biodegradable and a titanium system in Maxillofacial surgery. This multicenter RCT was performed in the Netherlands from December 2006 to July 2009. Included were 230 patients who underwent a bilateral sagittal split osteotomy (BSSO), a Le Fort-I osteotomy, or a bi-maxillary osteotomy and those treated for fractures of the mandible, maxilla, or zygoma. The patients were randomly assigned to a titanium group (KLS Martin) or to a biodegradable group (Inion CPS). Costs were assessed from a societal perspective. Health outcomes in the incremental cost-effectiveness ratio (ICER) were bone healing (8 weeks) and plate removal (2 years). In 25 out of the 117 patients who were randomized to the biodegradable group, the maxillofacial surgeon made the decision to switch to the titanium system intra-operatively. This resulted in an Intention-To-Treat (ITT-)analysis and a Treatment-Received (TR-) analysis. Both analyses indicated that operations performed with titanium plates and screws had better health outcomes. In the TR-analysis the costs were lower in the biodegradable group, in the ITT-analysis costs were lower in the titanium group. The difference in costs between the ITT and the TR analyses can be explained by the intra-operative switches: In the TR-analysis the switches were analysed in the titanium group. In the ITT-analysis they were analysed in the biodegradable group. Considering the cost-effectiveness the titanium system is preferable to the biodegradable system in the regular treatment spectrum of mandibular, Le Fort-I, and zygomatic fractures, and BSSO’s, Le Fort-I osteotomies and bimaxillary osteotomies. Controlled-Trials.com ISRCTN 44212338

1 October 2014 in British Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
NBNico van Bakelen
Nico van Bakelen
BBB.D.A. Boermans
B.D.A. Boermans
GBG.J. Buijs
G.J. Buijs
JJJ. Jansma
J. Jansma
GPG.J. Pruim
G.J. Pruim
RBR.R.M. Bos
R.R.M. Bos