Barzi Gareb

Mr. Barzi Gareb

University of Groningen, The Netherlands
+2
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2023 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
MRMatthew Brennand Roper
Matthew Brennand Roper
Arjan VissinkArjan Vissink
Arjan Vissink
TDTom Dudding
Tom Dudding
APAlex Pollard
Alex Pollard
BGBarzi Gareb
Barzi Gareb
RJRonald E. Jung
Ronald E. Jung
Purpose: The purpose of this study was to perform a systematic review with meta-analysis on the long-term survival rates of zygomatic implants (ZI). ZI success, prostheses survival and success, sinus pathology and patient reported outcomes were also investigated. Methods: Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines were followed. Embase and OvidMedline databases were searched alongside the grey literature. The systematic review was recorded in PROSPERO (CRD42022358024). Studies reporting titanium/titanium alloy ZI survival data, ZI-supported prosthesis data, ZIs directly compared to any other implant therapy including grafted sites, a minimum follow-up time of 3 years and a minimum number of 10 patients were included. All study designs were considered if they met the inclusion criteria. Studies not involving ZIs, ZIs not made from titanium/titanium alloy, a follow-up time of < 3 years or < 10 patients, animal studies and in vitro studies were excluded. Long-term follow-up has not been defined in the literature. A minimum of 3 years follow-up was considered acceptable to capture survival after initial healing, alongside in-function prosthesis data via delayed or immediate load protocols. ZI success, was predominantly defined as ZI survival without biological or neurological complications. Meta-analyses were performed for ZI survival, ZI failure incidence, ZI success, loading protocol, prosthesis survival, and prevalence of sinusitis using random effects models. Descriptive analysis was used for ZI success, prosthesis success and patient reported outcome measures. Results: Five hundred and seventy-four titles were identified, of which 18 met the inclusion criteria. Eligible studies included 1349 ZIs in 623 patients. Mean follow-up period was 75.4 months (range 36–141.6). The mean survival of ZIs was 96.2% [95% CI: 93.8; 97.7] at 6 years. Mean survival for delayed loading was 95% [95% CI: 91.7; 97.1] and 98.1% [95% CI: 96.2; 99.0] for immediate loading (p = 0.03). Annual incidence rate of ZI failure was 0.7% [95% CI 0.4; 1.0]. Mean ZI success was 95.7% [95% CI 87.8; 98.6]. Mean prosthesis survival was 94% [95% CI 88.6; 96.9]. Sinusitis prevalence was 14.2% [95% CI 8.8; 22.0] at 5 years. Patients’ reported increased satisfaction with ZIs. Conclusions: ZIs have long-term survival comparable to conventional implants. Immediate loading showed a statistically significant increase in survival over delayed loading. Prosthesis survival was similar to that of prostheses supported by conventional implants, with similar complications. Sinusitis was the most frequently encountered biological complication. Patients reported improved outcome measures with ZI use. Graphical

1 September 2016 in Injury
Verified
Journal Article
Closed access
MKM.E. de Koning
M.E. de Koning
BGBarzi Gareb
Barzi Gareb
MMM. El Moumni
M. El Moumni
MSM.E. Scheenen
M.E. Scheenen
HHH.J. van der Horn
H.J. van der Horn
Joukje Van der NaaltJoukje Van der Naalt
Joukje Van der Naalt

23 October 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
BGBarzi Gareb
Barzi Gareb
CRCharlotte C. Roossien
Charlotte C. Roossien
NBNico B. van Bakelen
Nico B. van Bakelen
GVGijsbertus J. Verkerke
Gijsbertus J. Verkerke
AVArjan Vissink
Arjan Vissink
BMBaucke van Minnen
Baucke van Minnen
To guide the selection of osteosynthesis systems, this study compared the mechanical properties of biodegradable and titanium osteosynthesis systems. SonicPins Rx and xG were subjected to pull-out tests. Additionally, 15 biodegradable (Inion CPS 2.0 and 2.5 mm; LactoSorb 2.0 mm; Macropore 2.0 mm; Polymax 2.0 mm; BioSorb FX 2.0 mm; ResorbX 2.1 mm; Osteotrans-MX 2.0 mm with plate thicknesses 1.0 and 1.4 mm; SonicWeld Rxplate/Rxpins, xGplate/Rxpins and xGplate/xGpins 2.1 mm without and with tapping the burr hole) and six titanium (CrossDrive (2006), CrossDrive (2018), MaxDrive; all 1.5 and 2.0 mm) straight, four-hole osteosynthesis systems were evaluated. All systems were subjected to tensile, bending and torsion tests. Pull-out loads of the SonicPins were comparable (P = 0.423). Titanium systems’ tensile loads were higher than biodegradable systems (P < 0.001). CrossDrive (2018) and MaxDrive systems’ tensile and torsional stiffness were lower, accompanied with higher ductility, than corresponding CrossDrive (2006) systems (P < 0.001). Bending stiffness of 1.5 mm titanium systems was comparable to, and of the 2.0 mm systems higher than, all biodegradable systems (P < 0.001). Regarding biodegradable systems, Inion CPS 2.5 mm had highest tensile load and torsional stiffness, SonicWeld 2.1 mm highest tensile stiffness, and BioSorbFX 2.0 mm highest bending stiffness (P < 0.001). On the basis of the results of this study, the CrossDrive (2018) and MaxDrive 1.5 mm titanium systems are recommended for midface fractures (e.g., zygomatic or maxillary fractures) and osteotomies (e.g., Le Fort I osteotomy), and the CrossDrive (2018) and MaxDrive 2.0 mm titanium systems for mandibular fractures and osteotomies when a titanium osteosynthesis system is used. When there is an indication for a biodegradable osteosynthesis system, the SonicWeld 2.1 mm or BioSorbFX 2.0 mm are recommended for midface fractures and osteotomies, and the Inion CPS 2.5 mm biodegradable system for mandibular osteotomies and non-load bearing mandibular fractures, especially when high torsional forces are expected (e.g., mandibular symphysis fractures).

11 May 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BGBarzi Gareb
Barzi Gareb
NBN. B. van Bakelen
N. B. van Bakelen
GBG. J. Buijs
G. J. Buijs
JJJ. Jansma
J. Jansma
JVJ. G. A. M. de Visscher
J. G. A. M. de Visscher
RBR. R. M. Bos
R. R. M. Bos
Biodegradable fixation systems could reduce or eliminate problems associated with titanium removal of implants in a second operation. The aim of this study was to compare the long-term (i.e. >5 years postoperatively) clinical performance of a titanium and a biodegradable system in oral and maxillofacial surgery. The present multicenter Randomized Controlled Trial (RCT) was performed in four hospitals in the Netherlands. Patients treated with a bilateral sagittal split osteotomy (BSSO) and/or a Le Fort-I osteotomy, and those treated for fractures of the mandible, maxilla, or zygoma were included from December 2006 to July 2009. The patients were randomly assigned to either a titanium (KLS Martin) or a biodegradable group (Inion CPS). After >5 years postoperatively, plate removal was performed in 22 of the 134 (16.4%) patients treated with titanium and in 23 of the 87 (26.4%) patients treated with the biodegradable system (P = 0.036, hazard ratio (HR) biodegradable (95% CI) = 2.0 (1.05–3.8), HR titanium = 1). Occlusion, VAS pain scores, and MFIQ showed good and (almost) pain free mandibular function in both groups. In conclusion, the performance of the Inion CPS biodegradable system was inferior compared to the KLS Martin titanium system regarding plate/screws removal in the abovementioned surgical procedures. http://controlled-trials.com ISRCTN44212338.

7 July 2022 in Polymers
Verified
Journal Article
Open access
PDF file
BGBarzi Gareb
Barzi Gareb
NBNico van Bakelen
Nico van Bakelen
Arjan VissinkArjan Vissink
Arjan Vissink
RBRuud R. M. Bos
Ruud R. M. Bos
BMBaucke Van Minnen
Baucke Van Minnen
Osteosynthesis systems are used to fixate bone segments in maxillofacial surgery. Titanium osteosynthesis systems are currently the gold standard. However, the disadvantages result in symptomatic removal in up to 40% of cases. Biodegradable osteosynthesis systems, composed of degradable polymers, could reduce the need for removal of osteosynthesis systems while avoiding the aforementioned disadvantages of titanium osteosyntheses. However, disadvantages of biodegradable systems include decreased mechanical properties and possible foreign body reactions. In this review, the literature that focused on the in vitro and in vivo performances of biodegradable and titanium osteosyntheses is discussed. The focus was on factors underlying the favorable clinical outcome of osteosyntheses, including the degradation characteristics of biodegradable osteosyntheses and the host response they elicit. Furthermore, recommendations for clinical usage and future research are given. Based on the available (clinical) evidence, biodegradable copolymeric osteosyntheses are a viable alternative to titanium osteosyntheses when applied to treat maxillofacial trauma, with similar efficacy and significantly lower symptomatic osteosynthesis removal. For orthognathic surgery, biodegradable copolymeric osteosyntheses are a valid alternative to titanium osteosyntheses, but a longer operation time is needed. An osteosynthesis system composed of an amorphous copolymer, preferably using ultrasound welding with well-contoured shapes and sufficient mechanical properties, has the greatest potential as a biocompatible biodegradable copolymeric osteosynthesis system. Future research should focus on surface modifications (e.g., nanogel coatings) and novel biodegradable materials (e.g., magnesium alloys and silk) to address the disadvantages of current osteosynthesis systems.

1 October 2016 in Journal of Children's Orthopaedics
Verified
Journal Article
Open access
JPJolanda J. de Poorter
Jolanda J. de Poorter
TBTom J. Beunder
Tom J. Beunder
BGBarzi Gareb
Barzi Gareb
HOHubert J. Oostenbroek
Hubert J. Oostenbroek
GBGert H. J. M. Bessems
Gert H. J. M. Bessems
Michiel A. J. van de SandeMichiel A. J. van de Sande
Michiel A. J. van de Sande
Purpose: Slipped capital femoral epiphysis (SCFE) is the commonest hip disorder in adolescents. In situ pinning is commonly performed, yet lately there has been an increase in procedures with open reduction and internal fixation. These procedures, however, are technically demanding with relatively high complication rates and unknown long-term outcomes. Nevertheless, reports on long-term results of in situ fixation are not equivocal. This study evaluates the possible higher risk of worse outcome after in situ pinning of SCFE. Methods: All patients treated for SCFE with in situ fixation between 1980 and 2002 in four different hospitals were asked to participate. Patients were divided into three groups, based on severity of the slip. Patients were invited to the outpatient clinic for physical examination and X-rays, and to fill out the questionnaires HOOS, EQ5D, and SF36. ANOVA and chi-squared tests were used to analyze differences between groups. Results: Sixty-one patients with 78 slips filled out the questionnaires. Patients with severe slips had worse scores on HOOS, EQ5D, and SF36. 75 % of patients with severe slips had severe osteoarthritis, compared to 2 % of mild and 11 % of moderate slips. Conclusion: Hips with mild and moderate SCFE generally had good functional and radiological outcome at a mean follow-up of 18 years, and for these hips there seems to be no indication for open procedures. However, severe slips have a significantly worse outcome, and open reduction and internal fixation could therefore be considered.