Amardeep M. Dugar

Dr. Amardeep M. Dugar

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2022 in Journal of Sustainable Architecture and Civil Engineering
Verified
Journal Article
Open access
PDF file
ODOva Candra Dewi
Ova Candra Dewi
KRKartika Rahmasari
Kartika Rahmasari
THTika Ardina Hanjani
Tika Ardina Hanjani
AIAgust Danang Ismoyo
Agust Danang Ismoyo
ADAmardeep M. Dugar
Amardeep M. Dugar
This study investigates the impact of Window-to-Wall Ratio (WWR) and Shading Coefficients (SC) as passive design strategies to optimise daylight in an opaque brick Double-Skin Façade (DSF) of an education building in Depok, Indonesia. A sample education building was simulated with DiaLux software for calculating the daylight distribution due to WWR on a daily basis during normal office hours. The optimum amount of window size and glazing were investigated for a typical floor plate area of 315.16m2. WWR was considered from 30% to 60% at 10% intervals in a horizontal and vertical expanding method of window. The simulations were performed in two sky conditions (sunny sky and standard CIE overcast sky) on different dates using glazing material of different SC. The primary findings of this study are that 40% WWR with SC 0.42 and 60% WWR with SC 0.95 achieve the best results for the north and south façade respectively of a DSF building.

9 June 2022 in Building and Environment
Verified
Journal Article
Closed access
KHKumar Hemalatha
Kumar Hemalatha
CIChandramathy I
Chandramathy I
RPRadhakrishnan Shanthi Priya
Radhakrishnan Shanthi Priya
ADAmardeep M. Dugar
Amardeep M. Dugar

23 August 2024 in Journal of Building Engineering
Verified
Journal Article
Closed access
SSSilvia Sebayang
Silvia Sebayang
ODOva Candra Dewi
Ova Candra Dewi
TPToga Panjaitan
Toga Panjaitan
KRKartika Rahmasari
Kartika Rahmasari
MDMuhammad Rowi Darmawiredja
Muhammad Rowi Darmawiredja
ADAmardeep M. Dugar
Amardeep M. Dugar

1 June 2024 in Light & Engineering
Verified
Journal Article
Closed access
PRPeter Raynham
Peter Raynham
ADAmardeep M. Dugar
Amardeep M. Dugar
This study demonstrates the possibility of growing green walls in normal commercial building environments with lighting designed primarily for aesthetic reasons, rather than the promotion of plant growth. Lighting is a key resource required for the growth and maintenance of robust green walls within interior environments. The study evaluated the appearance and growth of green walls with electric lighting used primarily for aesthetic reasons. Three identical green walls with six different plants were illuminated using three different white LED light sources for a period of five months. Plant health was monitored and documented in terms of successful growth patterns. One hundred and six subjects appraised the appearance of the walls using questionnaires. Findings of this study indicate that it is indeed possible to grow and maintain green walls in normal commercial building environments with lighting designed for aesthetic reasons. Further, key species were identified as appropriate for growing on internal green wall setups.

22 June 2023 in Journal of Sustainable Architecture and Civil Engineering
Verified
Journal Article
Open access
PDF file
VVViata Viriezky
Viata Viriezky
ODOva Candra Dewi
Ova Candra Dewi
ADAmardeep M. Dugar
Amardeep M. Dugar
This study aims to reduce the lighting energy consumption in educational buildings while avoiding an increase in cooling load. The Faculty of Engineering building in Universitas Indonesia, Depok, West Java, Indonesia is used as a case study. Daylight optimization can have an impact on lighting energy, which is the largest energy consumer in educational buildings. However, given Indonesia’s tropical climate, daylight leading to heat gain is a concern. Current passive design interventions for controlling daylight and heat gain include light shelves, clerestories, and glazing materials. Daylighting performance is simulated using DIALux software. Results of each intervention are analyzed quantitatively and qualitatively by theories and parameters, namely illuminance level, light uniformity, and overall thermal transfer value (OTTV). Light shelves result in increased uniformity and lower OTTV. Clerestories result in increased average illuminance but higher OTTV. Active intervention with a dimming and grouping system is applied after daylight increases. The combination of passive design interventions and active dimming of electric lights reduces lighting energy with the same OTTV as existing. This study recommends the use of passive and active daylighting strategies considering their effect on the cooling load of buildings.