Jan Suchánek

Dr. Jan Suchánek


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
VNVáclav Nevrlý
Václav Nevrlý
MDMichal Dostál
Michal Dostál
PBPetr Bitala
Petr Bitala
VKVít Klečka
Vít Klečka
JSJiří Sléžka
Jiří Sléžka
JWJan Wild
Jan Wild
Air pollution monitoring in industrial regions like Moravia-Silesia faces challenges due to complex environmental conditions. Low-cost sensors offer a promising, cost-effective alternative for supplementing data from regulatory-grade air quality monitoring stations. This study evaluates the accuracy and reliability of a prototype node containing low-cost sensors for carbon monoxide (CO) and particulate matter (PM), specifically tailored for the local conditions of the Moravian-Silesian Region during winter and spring periods. An analysis of the reference data observed during the winter evaluation period showed a strong positive correlation between PM, CO, and NO2 concentrations, attributable to common pollution sources under low ambient temperature conditions and increased local heating activity. The Sensirion SPS30 sensor exhibited high linearity during the winter period but showed a systematic positive bias in PM10 readings during Polish smog episodes, likely due to fine particles from domestic heating. Conversely, during Saharan dust storm episodes, the sensor showed a negative bias, underestimating PM10 levels due to the prevalence of coarse particles. Calibration adjustments, based on the PM1/PM10 ratio derived from Alphasense OPC-N3 data, were initially explored to reduce these biases. For the first time, this study quantifies the influence of particle size distribution on the SPS30 sensor’s response during smog episodes of varying origin, under the given local and seasonal conditions. In addition to sensor evaluation, we analyzed the potential use of data from the Copernicus Atmospheric Monitoring Service (CAMS) as an alternative to increasing sensor complexity. Our findings suggest that, with appropriate calibration, selected low-cost sensors can provide reliable data for monitoring air pollution episodes in the Moravian-Silesian Region and may also be used for future adjustments of CAMS model predictions.

16 June 2022 in Catalysts
Verified
Journal Article
Open access
PDF file
JSJan Suchánek
Jan Suchánek
EVEva Vaneckova
Eva Vaneckova
MDMichal Dostál
Michal Dostál
EMEliska Mikyskova
Eliska Mikyskova
LBLibor Brabec
Libor Brabec
Jiri RathouskyJiri Rathousky
Jiri Rathousky
The ISO standard 22197-1:2016 used for the evaluation of the photocatalytic nitric oxide removal has a main drawback, which allows only the decrease of nitric oxide to be determined specifically. The remaining amount, expressed as “NO2”, is considered as a sum of HNO3, HONO NO2, and other nitrogen-containing species, which can be potentially formed during the photocatalytic reaction. Therefore, we developed a new methodology combining our custom-made analyzers, which can accurately determine the true NO2 and HONO species, with the conventional NO one. Their function was validated via a photocatalytic experiment in which 100 ppbv of either NO or NO2 dispersed in air passed over (3 L min−1) an Aeroxide© TiO2 P25 surface. The gas-phase analysis was complemented with the spectrophotometric determination of nitrates (NO3−) and/or nitrites (NO2−) deposited on the P25 layer. Importantly, an almost perfect mass balance (94%) of the photocatalytic NOx abatement was achieved. The use of custom-made analyzers enables to obtain (i) no interference, (ii) high sensitivity, (iii) good linearity in the relevant concentration range, (iv) rapid response, and (v) long-term stability. Therefore, our approach enables to reveal the reaction complexity and is highly recommended for the photocatalytic NOx testing.

3 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
VNVáclav Nevrlý
Václav Nevrlý
MDMichal Dostál
Michal Dostál
PBPetr Bitala
Petr Bitala
VKVit Klecka
Vit Klecka
JSJiří Sléžka
Jiří Sléžka
JWJan Wild
Jan Wild
This study examines the varying performance of low-cost sensors during seasonal smog events, particularly those resulting from solid fuel combustion linked to residential or industrial heating and other pollution sources. A prototype low-cost sensor node developed within this work was collocated for several months with reference equipment at an air quality monitoring station in the city of Ostrava (Moravian-Silesian region, Czech Republic). Deterioration of air quality during a pair of smog alert events, namely wintertime "Polish smog" episode and springtime "Saharan dust storm", which occurred through the extended period of co-location, was characterized quantitatively based on particulate matter and carbon monoxide concentrations measured by the low-cost sensors. These datasets were compared with reference data and model predictions provided by the Copernicus Atmospheric Monitoring Service. Selected low-cost sensors demonstrated linear response during Polish smog episode with highly correlated time series of carbon monoxide and particulate matter concentrations. However, when compared to reference data, the Sensirion SPS30 sensor is found to overestimate coarse particle (PM10) concentrations by the factor of two during winter evaluation period. On the other hand, oppositely biased PM10 response (underestimation by the factor of five) was determined from co-location measurement during Saharan dust storm event. This observation was attributed to combination of specific detection efficiency of the given low-cost sensor and shifts in particle size distribution due to seasonal change of ambient conditions.