Václav Nevrlý

Dr. Václav Nevrlý

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Microchemical Journal
Verified
Journal Article
Closed access
JSJan Suchánek
Jan Suchánek
PJPavel Janda
Pavel Janda
MDMichal Dostál
Michal Dostál
AKAntonín Knížek
Antonín Knížek
PKPavel Kubát
Pavel Kubát
ZZZdeněk Zelinger
Zdeněk Zelinger

3 November 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
VNVáclav Nevrlý
Václav Nevrlý
MDMichal Dostál
Michal Dostál
PBPetr Bitala
Petr Bitala
VKVít Klečka
Vít Klečka
JSJiří Sléžka
Jiří Sléžka
JWJan Wild
Jan Wild
Air pollution monitoring in industrial regions like Moravia-Silesia faces challenges due to complex environmental conditions. Low-cost sensors offer a promising, cost-effective alternative for supplementing data from regulatory-grade air quality monitoring stations. This study evaluates the accuracy and reliability of a prototype node containing low-cost sensors for carbon monoxide (CO) and particulate matter (PM), specifically tailored for the local conditions of the Moravian-Silesian Region during winter and spring periods. An analysis of the reference data observed during the winter evaluation period showed a strong positive correlation between PM, CO, and NO2 concentrations, attributable to common pollution sources under low ambient temperature conditions and increased local heating activity. The Sensirion SPS30 sensor exhibited high linearity during the winter period but showed a systematic positive bias in PM10 readings during Polish smog episodes, likely due to fine particles from domestic heating. Conversely, during Saharan dust storm episodes, the sensor showed a negative bias, underestimating PM10 levels due to the prevalence of coarse particles. Calibration adjustments, based on the PM1/PM10 ratio derived from Alphasense OPC-N3 data, were initially explored to reduce these biases. For the first time, this study quantifies the influence of particle size distribution on the SPS30 sensor’s response during smog episodes of varying origin, under the given local and seasonal conditions. In addition to sensor evaluation, we analyzed the potential use of data from the Copernicus Atmospheric Monitoring Service (CAMS) as an alternative to increasing sensor complexity. Our findings suggest that, with appropriate calibration, selected low-cost sensors can provide reliable data for monitoring air pollution episodes in the Moravian-Silesian Region and may also be used for future adjustments of CAMS model predictions.

1 June 2016 in Nukleonika
Verified
Journal Article
Open access
PDF file
TBTomáš Blejchař
Tomáš Blejchař
VNVáclav Nevrlý
Václav Nevrlý
MVMichal Vašinek
Michal Vašinek
MDMichal Dostál
Michal Dostál
MKMilada Kozubková
Milada Kozubková
JWJan Wild
Jan Wild
The availability of reliable modeling tools and input data required for the prediction of surface removal rate from the lithium fluoride targets irradiated by the intense photon beams is essential for many practical aspects. This study is motivated by the practical implementation of soft X-ray (SXR) or extreme ultraviolet (XUV) lasers for the pulsed ablation and thin film deposition. Specifically, it is focused on quantitative description of XUV laser-induced desorption/ablation from lithium fluoride, which is a reference large band-gap dielectric material with ionic crystalline structure. Computational framework was proposed and employed here for the reconstruction of plume expansion dynamics induced by the irradiation of lithium fluoride targets. The morphology of experimentally observed desorption/ablation craters were reproduced using idealized representation (two-zone approximation) of the laser fluence profile. The calculation of desorption/ablation rate was performed using one-dimensional thermomechanic model (XUV-ABLATOR code) taking into account laser heating and surface evaporation of the lithium fluoride target occurring on a nanosecond timescale. This step was followed by the application of two-dimensional hydrodynamic solver for description of laser-produced plasma plume expansion dynamics. The calculated plume lengths determined by numerical simulations were compared with a simple adiabatic expansion (blast-wave) model.

1 August 2018 in Measurement Science Review
Verified
Journal Article
Open access
PDF file
VNVáclav Nevrlý
Václav Nevrlý
VKVít Klečka
Vít Klečka
MVMichal Vašinek
Michal Vašinek
VVVáclav Válek
Václav Válek
JSJan Suchánek
Jan Suchánek
ZZZdenĕk Zelinger
Zdenĕk Zelinger
This communication reports technical notes on the development and application of an automated line-shape fitting procedure for wavelength modulation spectroscopy (WMS). Near-infrared transitions of carbon dioxide (CO2) around 1573 nm were measured in vertical cold (nonreacting) flow of CO2 at atmospheric pressure using WMS with demodulation at second harmonic frequency. Semi-empirical model based on the set of so-called Gabor functions was developed and parameters of Lorentzian line-shape profile and its asymmetry resulting from simultaneous frequency and amplitude response of the current-modulated semiconductor laser were determined. Nonlinear least-square fitting procedure employing differential evolution algorithm was successfully utilized for performing this task. Line-shape fitting procedure enabling efficient signal de-noising and background subtraction of wavelength modulation spectra was implemented into an open-source code.

31 January 2025 in Journal of Loss Prevention in the Process Industries
Verified
Journal Article
Closed access
HCHana Chaloupecká
Hana Chaloupecká
VNVáclav Nevrlý
Václav Nevrlý
BMBarbora Martiníkova
Barbora Martiníkova
JSJan Suchánek
Jan Suchánek
MDMichal Dostál
Michal Dostál
ZJZbyněk Jaňour
Zbyněk Jaňour

1 July 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
VNVáclav Nevrlý
Václav Nevrlý
PBP Bitala
P Bitala
VKV Klečka
V Klečka
MVM Vašinek
M Vašinek
ZZZ Zelinger
Z Zelinger
VVV Válek
V Válek
This work is aimed at the application of wavelength modulation spectroscopy with the second harmonic detection for determination of OH radical concentration in laminar premixed flames of methane-air mixtures. Several hot water lines and two overtone OH transitions were identified in high-resolution absorption spectra measured in our experimental setup. Information on spectral line-shape parameters for selected OH transitions were extracted from the experimental data using relevant methods and approximations. An appropriate line-shape model was finally implemented into an automated least-square fitting procedure in order to quantify the local mole fraction of OH radical in an atmospheric pressure flames.