Mahmoud Abdelhamid Ahmed Ali

Dr. Mahmoud Abdelhamid Ahmed Ali

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
MAMahmoud Abdelhamid Ahmed Ali
Mahmoud Abdelhamid Ahmed Ali
Salah KamelSalah Kamel
Salah Kamel
Mohamed Hosny HassanMohamed Hosny Hassan
Mohamed Hosny Hassan
EAEmad M. Ahmed
Emad M. Ahmed
MAMohana Alanazi
Mohana Alanazi
Modern electrical power systems are becoming increasingly complex and are expanding at an accelerating pace. The power system’s transmission lines are under more strain than ever before. As a result, the power system is experiencing a wide range of issues, including rising power losses, voltage instability, line overloads, and so on. Losses can be minimized and the voltage profile can be improved when energy resources are installed on appropriate buses to optimize real and reactive power. This is especially true in densely congested networks. Optimal power flow (OPF) is a basic tool for the secure and economic operation of power systems. It is a mathematical tool used to find the instantaneous optimal operation of a power system under constraints meeting operation feasibility and security. In this study, a new application algorithm named white shark optimizer (WSO) is proposed to solve the optimal power flow (OPF) problems based on a single objective and considering the minimization of the generation cost. The WSO is used to find the optimal solution for an upgraded power system that includes both traditional thermal power units (TPG) and renewable energy units, including wind (WPG) and solar photovoltaic generators (SPG). Although renewable energy sources such as wind and solar energy represent environmentally friendly sources in line with the United Nations sustainable development goals (UN SDG), they appear as a major challenge for power flow systems due to the problems of discontinuous energy production. For overcoming this problem, probability density functions of Weibull and Lognormal (PDF) have been used to aid in forecasting uncertain output powers from WPG and SPG, respectively. Testing on modified IEEE-30 buses’ systems is used to evaluate the proposed method’s performance. The results of the suggested WSO algorithm are compared to the results of the Northern Goshawk Optimizer (NGO) and two other optimization methods to investigate its effectiveness. The simulation results reveal that WSO is more effective at finding the best solution to the OPF problem when considering total power cost minimization and solution convergence. Moreover, the results of the proposed technique are compared to the other existing method described in the literature, with the results indicating that the suggested method can find better optimal solutions, employ less generated solutions, and save computation time.

27 June 2025 in Journal of Applied Polymer Science
Verified
Journal Article
Closed access
MAMahmoud Abdelhamid Ahmed Ali
Mahmoud Abdelhamid Ahmed Ali
Xingliang JiangXingliang Jiang
Xingliang Jiang
QHQin Hu
Qin Hu
HZHang Zhang
Hang Zhang
AMAhmed S. Menesy
Ahmed S. Menesy
RDRuta W. Deusdedith
Ruta W. Deusdedith

13 February 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
MAMahmoud Abdelhamid Ahmed Ali
Mahmoud Abdelhamid Ahmed Ali
Xingliang JiangXingliang Jiang
Xingliang Jiang
Salah KamelSalah Kamel
Salah Kamel
AAAsad Awan
Asad Awan
This study explores the impact of various high-voltage insulator string configurations on pollution and icing flashover characteristics under different environmental conditions. The inverted T-string design is suggested, offering improvements over the traditional I-string configuration. An experimental investigation is conducted using high-voltage glass-type disks (LD-160), along with the development of two artificial neural network (ANN) models to simulate and predict flashover voltages. The results demonstrate that the inverted T-string arrangement enhances the flashover voltage for polluted insulator strings by approximately 7% and increases the icing flashover voltage by 3.43%–5.01% compared to standard I-strings. The ANN models successfully determine optimal insulator configurations, demonstrating their potential to enhance high-voltage insulation performance with minimal experimentation. This study emphasizes the innovative use of ANN in optimizing insulator string arrangements, providing a practical solution for tackling pollution and icing issues in power systems.

5 August 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
RDRuta W. Deusdedith
Ruta W. Deusdedith
Xingliang JiangXingliang Jiang
Xingliang Jiang
MAMahmoud Abdelhamid Ahmed Ali
Mahmoud Abdelhamid Ahmed Ali
KNKhatri Nirajan
Khatri Nirajan
DZDong Zeng
Dong Zeng
The utilization of epoxy resin insulators for high voltage insulation continues to expand; however, surface flashover remains its significant challenge. Conventional methods for improving surface flashover voltage in epoxy insulators basically focus on physical and chemical changes while neglecting environmental and sustainability concerns involving petroleum epoxy resins. In this study, eco-friendly castor oil is incorporated into the epoxy matrix to enhance surface flashover voltage while promoting reduction of overreliance on finite petroleum resources. The successful integration of castor oil into the epoxy matrix is confirmed by Fourier Transform Infrared Spectroscopy, whereas the Atomic Force Microscopy and Scanning Electron Microscopy reveal smooth surfaces of composites at relatively low concentrations of castor oil, while higher concentrations beyond 30% lead to an increase in roughness. Samples’ relative permittivities are analyzed by using a Novocontrol spectrometer, which reveals the decrease in relative permittivity with the addition of castor oil into epoxy matrix. Notably, the positive and negative flashover voltages are enhanced by 17.47% and 18.49% respectively, at a castor oil concentration of 30 wt% with respect to epoxy resin, which is attributed to moderate trap parameters alongside favorable charge carrier mobility. These findings suggest that epoxy-castor oil biocomposite is a potential high voltage insulation material with reduced petroleum quantity and enhanced flashover voltage.

16 March 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
MAMahmoud Abdelhamid Ahmed Ali
Mahmoud Abdelhamid Ahmed Ali
Xingliang JiangXingliang Jiang
Xingliang Jiang
Hualong ZhengHualong Zheng
Hualong Zheng
XZXiaolong Zhang
Xiaolong Zhang
KNKhatri Nirajan
Khatri Nirajan
RDRuta W. Deusdedith
Ruta W. Deusdedith
This study investigates the surface degradation behavior of silicone rubber (SiR) composites filled with two-dimensional (2D) nanosheets—molybdenum disulfide (MoS₂) and tungsten disulfide (WS₂)—under high-voltage direct current (HVDC) tracking and erosion stress. Using standardized DC inclined plane testing (IEC 60587, IEEE Std 2652™-2021), the performance of 2D-filled composites is compared with conventional fillers, including aluminum trihydrate (ATH) and fumed silica, at a fixed loading of 5 wt.%. Key parameters such as eroded mass, track length, erosion depth, leakage current, thermal conductivity, and thermal stability are evaluated. Results show that 2D nanosheets significantly reduce erosion and tracking length, maintain lower and more stable surface temperatures, and enhance thermal stability compared to neat SiR and spherical-filler composites. MoS₂ and WS₂ fillers demonstrate superior performance, attributed to their high aspect ratios, layered morphology, and strong interfacial bonding with the SiR matrix, which promote tortuous thermal/electrical pathways and thermally stable char formation. The findings highlight the effectiveness of 2D nanofillers in developing advanced, erosion-resistant silicone rubber insulators for HVDC environments and underscore the critical role of filler morphology in optimizing DC tracking and erosion performance.

10 June 2026 in High Voltage
Verified
Journal Article
Open access
MAMahmoud Abdelhamid Ahmed Ali
Mahmoud Abdelhamid Ahmed Ali
Xingliang JiangXingliang Jiang
Xingliang Jiang
SGSamir I. Gadow
Samir I. Gadow
RDRuta W. Deusdedith
Ruta W. Deusdedith
The long‐term hydrophobic stability of silicone rubber (SiR) insulators is essential for their reliability in high‐voltage direct current (HVDC) applications. This study investigates the effect of nano‐silica fillers with varying specific surface areas (SSA = 120, 200 and 300 m 2 /g) and different concentrations of alumina trihydrate (ATH) fillers (5–50 wt.%) on the dynamic hydrophobicity of SiR using the dynamic drop test (DDT) under HVDC stress. Key performance indicators—hydrophobicity retention, recovery and transfer—were evaluated. Experimental results indicate that nano‐silica, particularly with an SSA of 200 m 2 /g, (SFS200) significantly improves hydrophobic performance, offering the best balance of retention time, recovery, transfer and reproducibility. In contrast, high ATH loadings hinder the migration of low molecular weight and reduce recovery. Moderate ATH content (10 wt.%) showed optimal performance among ATH‐filled samples but was still inferior to silica‐filled composites. Although higher SSA enhanced retention time, an excessively high SSA (300 m 2 /g) resulted in agglomeration and consequently reduced recovery. These results confirm the superiority of fumed silica in improving the hydrophobic stability of SiR insulators and highlight the critical role of filler characteristics—particularly SSA, porosity and dispersion—in optimising SiR performance under HVDC stress. The study also demonstrates that additional experimental precautions improved DDT reproducibility, supporting its use in future standardisation.