Steel-to-concrete bond is a basic aspect of the behaviour of reinforced concrete structures both at serviceability and ultimate states. When bond rules were originally developed, experimental results were mainly obtained on normal-strength concrete and a minimum relative rib area (bond index) was required by building codes to ensure good bond properties. The arrival into the market of high-performance concrete and newer structural needs may require different bond indexes. In the present paper, the experimental results of pull-out tests on short anchorages are presented. Several pull-out tests on ribbed bars, embedded in cubes of normal- and high-strength concrete with a concrete cover of 4·5 times the bar diameter, were carried out in order to better understand the influence of the relative rib area and bar diameter on the local bond behaviour, as well as on the splitting crack width generated by the wedging action of ribs. A total of 96 tests were performed on machined bars of three different diameters (12, 16 and 20 mm) with a bond index ranging from 0·040 to 0·105. The results of 55 pull-out tests on commercial hot-rolled ribbed bars of four different diameters (12, 20, 40 and 50 mm) are also presented to confirm that the bond response also depends on bar diameter (size effect). Experimental results provide information concerning the influence of the relative rib area on bond strength and on the bursting force due to the rib's wedge action. As the minimum measured bond strength of rebars was always markedly greater than the minimum bond strength required by building codes even when low bond indexes were adopted, the test results point out the possibility of reducing the minimum value of the relative rib area required by Eurocode 2 without limiting the safety coefficient of bond. The reduction also allows a higher structural ductility that can be achieved due to a greater strain penetration of the rebars from concrete cracks.
3 September 2017 in European Journal of Environmental and Civil Engineering
In this paper, an integrated approach targeting sustainability, safety and resilience is envisioned for the renovation of the post-Second World War RC buildings clustered in urban outskirts. The solution stems as an enhancement of the widespread camouflage practice, which targets energy efficiency and architectural restyling by complementing the building with a technological double skin, self-supported on an independent exoskeleton. Based on this integrated approach, the exoskeleton can be further engineered to also enable structural safety and resilience. Life cycle thinking is addressed to re-conceive traditional structural design approaches, guaranteeing safety, while minimising costs and environmental impacts over the building life cycle. Accurate selection of materials and dry technologies enables adaptability, reparability and maintenance, and total recyclability/reuse at end-of-life. The intervention is carried out from outside, avoiding relocation of the inhabitants and possible building downtime. The paper introduces a possible framework for engineers, technologists and architects to design new holistic renovation interventions, for which innovative solution sets are required. Possible structural techniques to be coupled with energy refurbishment are proposed. As a proof of concept, the envisaged holistic renovation strategy is applied to a reference building, and benefits entailed in combining structural safety measures within an integrated intervention are commented.
1 June 2017 in Construction and Building Materials
In the present paper, the effectiveness of a High Performance Fibre Reinforced Concrete (HPFRC) jacket for the seismic retrofitting of existing RC corner beam-column joints is experimentally investigated. The results of cyclic experimental tests on full-scale corner beam-column sub-assemblies (two unretrofitted and two retrofitted) are presented and discussed in detail, focusing on the effectiveness of the adopted retrofitting technique. The RC test units were designed with structural deficiencies typical of the Italian construction practice of the 70’s: use of smooth bars, inadequate reinforcement detailing, such as lack of stirrups in the joint panel, and hook-ended anchorage. The results underlined that the joint panel strength impairs the seismic response of the sub-structure with a drift at incipient collapse not greater than 2%. The results showed that the application of thin HPFRC jackets appears a promising technique to strengthen poorly-detailed RC joints: the jacket was able to increase the shear strength of the joint by about 40%, with respect to the bare joint, limiting the damage of the retrofitted sub-assembly, which reached an ultimate drift of 6%
The structural performance of timber elements may depend on the environmental conditions and in particular on the cyclic variations of the moisture content. Moisture gradients in the sections of the structural elements can produce additional stresses, the so-called moisture-induced stresses (MIS), which can cause the formation of cracks and delamination in wooden components. In order to achieve a reliable evaluation of the safety level of timber structures, the present paper proposes a numerical methodology to evaluate the MIS in glulam beams of timber bridges under Northern European climates and mechanical loads. A hygro-thermal multi-Fickian model for prediction of moisture content, relative humidity and temperature in wood is sequentially coupled with an orthotropic-viscoelastic-mechanosorptive model for calculation of wood stresses. Both models were developed by some of the authors in Abaqus FEM code in previous works and their coupling is used here to analyse the hygro-thermo-mechanical response of a glulam beam of Vihantasalmi Bridge in Finland under bending loads. Both perpendicular and parallel to grain MIS in a beam section sheltered from rain are evaluated during a 10-year analysis and conclusions on the crack risk related to these stresses are given.