Abdullah Alshehri

Dr. Abdullah Alshehri

Prosthodontics, King Khalid University, Abhā, ‘Asīr, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2023 in Medicina
Verified
Journal Article
Open access
PDF file
SJSaurabh Jain
Saurabh Jain
Mohammed SayedMohammed Sayed
Mohammed Sayed
WIWael Ibraheem
Wael Ibraheem
AAAbrar A. Ageeli
Abrar A. Ageeli
SGSumir Gandhi
Sumir Gandhi
YYahya Aljabri
Yahya Aljabri
Background and Objectives: The present systematic review and meta-analysis undertake a comparison of studies that examine the accuracy of robot-assisted dental implant placement in relation to static computer-assisted implant surgery (SCAIS), dynamic computer-assisted implant surgery (DCAIS), and freehand procedures. This study aims to provide a comprehensive understanding of the precision of robot-assisted dental implant placement and its comparative efficacy in relation to other placement techniques. Methods: The guidelines recommended by Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) were used to organize and compose this review. Four electronic databases (PubMed, Web of Science, Scopus, and Cochrane) were systematically searched for pertinent articles. Articles were selected following the inclusion and exclusion criteria. Qualitative and quantitative analyses of the selected articles were performed. Results: The initial electronic search resulted in 1087 hits. Based on the inclusion and exclusion criteria, five articles were selected for qualitative analysis, out of which three were considered for quantitative analysis. Three parameters were considered for accuracy evaluation (angular, coronal, and apical deviation). The mean angular deviation was −1.22 degrees (95% CI, −1.06–−1.39), the mean coronal deviation was −0.15 mm (95% CI, −0.24–−0.07), and the mean apical deviation was −0.19 mm (95% CI, −0.27–−0.10). Conclusions: The robotic implant system was found to have significantly lower angular deviations and insignificantly lower coronal and apical deviations compared to DCAIS. Within the limitations of this review, it can be concluded that robot-assisted implant placement in resin models permits higher accuracy compared to DCAIS and SCAIS systems. However, due to the limited number of comparative studies with high heterogeneity, the findings of this review should be interpreted with caution. Further research is necessary to confirm the clinical application of robotics in implant surgery.

20 November 2022 in Coatings
Verified
Journal Article
Open access
PDF file
MAmohammed alwadei
mohammed alwadei
Mohammed SayedMohammed Sayed
Mohammed Sayed
SJSaurabh Jain
Saurabh Jain
AAAparna Aggarwal
Aparna Aggarwal
HAHatem Al-qarni
Hatem Al-qarni
MGMafaz M. Gharawi
Mafaz M. Gharawi
The aim of this systematic review was to evaluate the marginal fit and internal adaptation of provisional crowns and fixed dental prostheses (FDPs) fabricated using 3D-printing resins and compared them with those fabricated by CAD/CAM (computer-aided designing/computer-aided manufacturing) milling and conventional resins. The null hypotheses tested were that there would be no differences in the marginal fit and internal adaptation of 3D-printed provisional crowns and FDP resins when compared to CAD/CAM-milled and conventional provisional resins. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used to construct this systematic review. The focused PICO/PECO (Population, Intervention/Exposure, Comparison, Outcome) question was “Do provisional crowns and FDPs (P) fabricated by 3D-printing (I) have similar marginal adaptation and internal fit (O) when compared to those fabricated by CAD/CAM milling and conventional techniques (C)?”. The protocol used for this systematic review was pre-registered in the International Prospective Register of Systematic Reviews (PROSPERO). Electronic databases (e.g., MEDLINE/PubMed and Web of Science (Core Collection)) were systematically searched for indexed English literature published up to June 2022. In the initial electronic search of the selected databases, 519 articles were identified. Duplicates were removed, and screening was performed to select the articles that met the preset inclusion criteria. Sixteen studies were selected for qualitative analysis, but only ten of them provided comparative data and were selected for quantitative analysis. The modified CONSORT scale was used for qualitative analysis, and most of the included studies were rated to be of moderate quality. Based on the findings, it could be concluded that provisional crowns and FDPs fabricated from 3D-printing resins have a superior marginal fit and internal adaptation when compared to CAD/CAM-milled and conventional provisional resins; thus, they can be used as a dependable alternative to other resins.

28 October 2024 in Medical Science Monitor
Verified
Journal Article
Open access
SJSaurabh Jain
Saurabh Jain
Mohammed SayedMohammed Sayed
Mohammed Sayed
RKReem Abdullah A. Khawaji
Reem Abdullah A. Khawaji
GHGhada Ali J. Hakami
Ghada Ali J. Hakami
ESEman Hassan M. Solan
Eman Hassan M. Solan
KMKhurshid Mattoo
Khurshid Mattoo
Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis: An In Vitro Study - Article abstract #946624

15 February 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
MMMaryam Mugri
Maryam Mugri
HDHarisha Dewan
Harisha Dewan
Mohammed SayedMohammed Sayed
Mohammed Sayed
FSFawzia Ibraheem Shaabi
Fawzia Ibraheem Shaabi
HHHanan Ibrahim Hakami
Hanan Ibrahim Hakami
HCHitesh Chohan
Hitesh Chohan
The aim of this study is to investigate the combined effect of a digital manufacturing technique (subtractive vs. additive), preparation taper (10° vs. 20° TOC), and finish line (chamfer vs. shoulder) on the marginal adaptation of temporary crowns following cementation with a compatible temporary cement. Four mandibular first molar typodont teeth were prepared for full coverage crowns with standard 4 mm preparation height as follows: 10° TOC with the chamfer finish line, 10° TOC with the shoulder finish line, 20° TOC with the chamfer finish line and 20° TOC with the shoulder finish line. Each of the four preparation designs were subdivided into two subgroups to receive CAD/CAM milled and 3D-printed crowns (n = 10). A total of 80 temporary crowns (40 CAD/CAM milled and 40 3D-printed) were cemented to their respective die using clear temporary recement in the standard cementation technique. The samples were examined under a stereomicroscope at ×100 magnification following calibration. Linear measurements were performed at seven equidistant points on each axial surface and five equidistant points on each proximal surface. One-way ANOVA analysis and Tukey HSD (Honestly Significance Difference) were performed. The best marginal fit was seen in group 8, while the poorest fit was noted in group 2. Shoulder finish lines and 10° TOC resulted in higher marginal gaps, especially in CAD/CAM milled group. The selection of 3D-printed crowns may provide a better marginal fit within the range of clinical acceptability. Marginal gaps were within clinical acceptability (50 and 120 µm) in all groups except group 2.

6 March 2025 in Polymers
Verified
Journal Article
Open access
PDF file
NHNisreen Nabiel Hassan
Nisreen Nabiel Hassan
KMKhurshid Mattoo
Khurshid Mattoo
AKAtheer Hassan Khawaji
Atheer Hassan Khawaji
HNHanan Hussain Najmi
Hanan Hussain Najmi
ASAlmaha Ahmed Sadeli
Almaha Ahmed Sadeli
Mohammed SayedMohammed Sayed
Mohammed Sayed
This study determined the influence of surface treatment and protracted ageing on the shear bond strength (SBS) of orthodontic brackets bonded to CADCAM (milled) and 3D-printed polymethylmethacrylate (PMMA) provisional crowns (PCs). Eighty disc-shaped specimens [forty milled (CopraTemp WhitePeaks) [group (Gp) M] and forty printed (Asiga DentaTooth) (Gp P)] were divided into eight subgroups (Gp) based on surface treatment [no treatment (control) (Gp MC and Gp PC), coarse diamond (Gp MCD and Gp PCD), fine diamond (Gp MFD, and GP PFD) and sandblast (Gp MSB and Gp PSB)]. Orthodontic brackets were bonded (Assure Plus, Transbond XT), thermocycled (2200 cycles), and tested for SBS and failure (Adhesive Remnant Index) (ARI). Statistical tests included analysis of variance (ANOVA); Kruskal–Wallis (ARI ranks); and post hoc (Tukey, Dunn, and Bonferroni) for determining group differences at predetermined probability p-values less than 0.05. SBS was significantly increased in Gp MSB (15.51 Mpa) and Gp PSB (14.11 Mpa), while the coarse diamond subgroups yielded the lowest mean SBS values [Gp MCD (11.28 Mpa) and Gp PCD (11.62 Mpa)]. The SBS of subgroups MFD, MSB, PCD, and PSB showed significant differences from those of their respective controls (Gp MC and Gp PC). Low ARI scores were observed in Gp MC (0.40) and Gp MSB (0.80), while higher scores were observed in Gp PCD (2.10). Both milled and printed PCs fulfil the clinical criteria of the minimum SBS for orthodontic brackets for long-term use. However, milled PC has better SBS and low ARI scores, which make it more clinically feasible for orthodontic treatments.

22 December 2023 in Medical Science Monitor
Verified
Journal Article
Open access
Mohammed SayedMohammed Sayed
Mohammed Sayed
Kulashekar Reddy NandalurKulashekar Reddy Nandalur
Kulashekar Reddy Nandalur
NRNaveen R. Reddy
Naveen R. Reddy
KMKhurshid Mattoo
Khurshid Mattoo
YJYaser Ali Jad
Yaser Ali Jad
MAMashael Abdullah AlNijaiban
Mashael Abdullah AlNijaiban
Background: This study evaluated the effects of milling (CADCAM), 3D printing, preparation taper angles (10 -degree and 20 -degree), auxiliary retentive features (groove and box), and provisional cement types (conventional and resin -based) on the adhesive failure stress of 3 -mm short provisional crowns (PC). The research was motivated by the need to understand how digital dentistry technologies impact the retention and durability of provisional crowns. Material/Methods: A total of 160 working models (3D -printed) and PCs [80 milled (CopraTemp)/80 printed (Asiga)] were fabricated from two 10- and 20 -degree typodont master models and two 20 -degree 3D -printed master models (groove and box), simulating a 3 mm high all -ceramic short PC. After provisional cementation with conventional (Kerr TempBond) and resin -based (ProviTemp) cements, 16 subgroups (n=10 each) underwent thermocycling (10 000 cycles; 5-55 degrees C) and pull -off tests on a universal testing machine. Statistical analysis was performed using oneway ANOVA and post hoc Tukey test. Results: Conventional cement failed at lower stress for milled (47.68 to 73.54) and printed (48.40 to 77.91) as compared to resin cement for milled (104.2 to 137.27) and printed (184.85 to 328.84), respectively, with significant differences. Increased taper and groove decreased failure load except for the printed PC/resin cement combination. Use of proximal box preparation increased retention significantly. Except for 20 -degree taper cemented with conventional cement, the differences in auxiliary retentive features for milled and printed provisional crowns were statistically significant at P 0.05 pound. Conclusions: 3D -printed PC, resin -based cement, 10 -degree taper, and proximal box preparation were associated with higher retention than milled, conventional cements, 20 -degree taper, and vertical groove.