Nisreen Nabiel Hassan

Dr. Nisreen Nabiel Hassan


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2025 in Polymers
Verified
Journal Article
Open access
PDF file
NHNisreen Nabiel Hassan
Nisreen Nabiel Hassan
KMKhurshid Mattoo
Khurshid Mattoo
AKAtheer Hassan Khawaji
Atheer Hassan Khawaji
HNHanan Hussain Najmi
Hanan Hussain Najmi
ASAlmaha Ahmed Sadeli
Almaha Ahmed Sadeli
Mohammed SayedMohammed Sayed
Mohammed Sayed
This study determined the influence of surface treatment and protracted ageing on the shear bond strength (SBS) of orthodontic brackets bonded to CADCAM (milled) and 3D-printed polymethylmethacrylate (PMMA) provisional crowns (PCs). Eighty disc-shaped specimens [forty milled (CopraTemp WhitePeaks) [group (Gp) M] and forty printed (Asiga DentaTooth) (Gp P)] were divided into eight subgroups (Gp) based on surface treatment [no treatment (control) (Gp MC and Gp PC), coarse diamond (Gp MCD and Gp PCD), fine diamond (Gp MFD, and GP PFD) and sandblast (Gp MSB and Gp PSB)]. Orthodontic brackets were bonded (Assure Plus, Transbond XT), thermocycled (2200 cycles), and tested for SBS and failure (Adhesive Remnant Index) (ARI). Statistical tests included analysis of variance (ANOVA); Kruskal–Wallis (ARI ranks); and post hoc (Tukey, Dunn, and Bonferroni) for determining group differences at predetermined probability p-values less than 0.05. SBS was significantly increased in Gp MSB (15.51 Mpa) and Gp PSB (14.11 Mpa), while the coarse diamond subgroups yielded the lowest mean SBS values [Gp MCD (11.28 Mpa) and Gp PCD (11.62 Mpa)]. The SBS of subgroups MFD, MSB, PCD, and PSB showed significant differences from those of their respective controls (Gp MC and Gp PC). Low ARI scores were observed in Gp MC (0.40) and Gp MSB (0.80), while higher scores were observed in Gp PCD (2.10). Both milled and printed PCs fulfil the clinical criteria of the minimum SBS for orthodontic brackets for long-term use. However, milled PC has better SBS and low ARI scores, which make it more clinically feasible for orthodontic treatments.

23 December 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
SASaeed M. Alqahtani
Saeed M. Alqahtani
MAMohammed Salman j. Almalki
Mohammed Salman j. Almalki
MAMai Almarzouki
Mai Almarzouki
SASaad AlResayes
Saad AlResayes
NHNisreen Nabiel Hassan
Nisreen Nabiel Hassan
Mohammed SayedMohammed Sayed
Mohammed Sayed
Background: This study aims to perform a review by selecting, analyzing, and evaluating articles that discuss the accuracy of intraoral scanners (IOSs) in recording post space compared to conventional impression-making techniques. Methods: The review question framed using the PITR framework (participant, index test, targeted condition, and reference standard) is as follows: What is the dimensional accuracy (T) of impressions made using intraoral scanners (I) for post space (P) compared to impressions made using conventional techniques and digitalized using extraoral scanners (R)? Four electronic databases were searched using pre-set keywords. The guidelines and strategies recommended by PRISMA formed the basis for planning, executing, and documenting this systematic review. QUADAS-2 was used to critically analyze the quality of all the selected articles. Results: After excluding ineligible articles, the end synthesis has nine studies (n = 9) for qualitative analysis. All nine evaluated studies were found to be at risk of bias, with high or unclear risk in one or more domains. Three out of nine evaluated studies had unclear concerns regarding the applicability, and the remaining six had low concerns. In all the included studies, the IOSs were reported to have deviations in accuracy compared to the conventional techniques for making digital impressions of post space. Conclusions: The accuracy of IOSs was found to be inversely proportional to the length of post space and directly proportional to the diameter of post space. IOSs, when used adequately in short post spaces, can be an alternative to conventional impression-making for making custom posts and cores.

22 December 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
NHNisreen Nabiel Hassan
Nisreen Nabiel Hassan
A wide range of commercially available vinylpolysiloxane-based (VPS) bite registration record (BRR) materials having polymerization time (PT) in a range of