Francesco Paolo Romano

Dr. Francesco Paolo Romano

Istituto di Scienze per il Patrimonio Culturale (ISPC), Consiglio Nazionale delle Ricerche (CNR), Via Biblioteca 4, 95124 Catania, Italy
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2017 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
Francesco Paolo RomanoFrancesco Paolo Romano
Francesco Paolo Romano
CCClaudia Caliri
Claudia Caliri
PNPaolo Nicotra
Paolo Nicotra
SMSandra Di Martino
Sandra Di Martino
LPLighea Pappalardo
Lighea Pappalardo
HSHellen Cristine Santos
Hellen Cristine Santos
A novel mobile macro-XRF (MA-XRF) scanning technique allowing real-time elemental imaging is presented for the investigation of macroscopic paintings. The instrument is based on a microfocus X-ray tube focused with a polycapillary and two SDD detectors operated simultaneously in a time-list event mode. The scanner is based on a three-axis system covering a dimension of 110 × 70 × 20 cm3. MA-XRF scanning is generally performed by positioning samples out of the polycapillary focus with the primary X-ray beam presenting a spot size in the range of hundreds of microns. However, a lateral resolution of up to 25 μm can be achieved at the focus position, allowing complementary use of the scanner for both micro-XRF and macro-XRF mapping. Scanning of artworks is performed with a maximum continuous speed of 100 mm s−1. The full area is covered in 4.3 h in the case of final images presenting a 500 μm pixel size (i.e., corresponding to a dwell time per pixel of 5 ms). The system is controlled with a custom developed control unit (CU) including a graphical user interface (GUI) programmed in Labview for real-time control of all sensors in the scanner and for real-time elaboration of X-ray data. X-ray spectra are processed during the scanning by the least square fast fitting procedure developed in PyMCa and integrated in the system. Up to 7000 fitted spectra per second are possible. A number of editing, processing and mathematical tools are available to users in the GUI and can be applied in a live mode to the forming elemental images. The sum spectrum and maximum pixel spectrum are continuously updated. Final images are available at the end of the scanning and, in most of the cases, they are ready for the interpretation.

4 October 2014 in Analytical Chemistry
Verified
Journal Article
Closed access
Francesco Paolo RomanoFrancesco Paolo Romano
Francesco Paolo Romano
CCClaudia Caliri
Claudia Caliri
LCLuigi Cosentino
Luigi Cosentino
SGSanto Gammino
Santo Gammino
Lorenzo GiuntiniLorenzo Giuntini
Lorenzo Giuntini
FTFrancesco Taccetti
Francesco Taccetti

1 July 2002 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
MBM Bicchieri
M Bicchieri
SRS Ronconi
S Ronconi
Francesco Paolo RomanoFrancesco Paolo Romano
Francesco Paolo Romano
LPL Pappalardo
L Pappalardo
MCM Corsi
M Corsi
ETE Tognoni
E Tognoni

31 March 2011 in Microchemical Journal
Verified
Journal Article
Closed access
FRF. Rizzo
F. Rizzo
GCGiuseppe Pablo Cirrone
Giuseppe Pablo Cirrone
GCGiacomo Cuttone
Giacomo Cuttone
AEA. Esposito
A. Esposito
SGS. Garraffo
S. Garraffo
SRS. Russo
S. Russo

2 December 2005 in X-Ray Spectrometry
Verified
Journal Article
Closed access
PDF file
Francesco Paolo RomanoFrancesco Paolo Romano
Francesco Paolo Romano
GPG. Pappalardo
G. Pappalardo
LPL. Pappalardo
L. Pappalardo
SGS. Garraffo
S. Garraffo
RGR. Gigli
R. Gigli
APA. Pautasso
A. Pautasso

23 April 2003 in Archaeometry
Verified
Journal Article
Closed access
PDF file
LPL. Pappalardo
L. Pappalardo
Francesco Paolo RomanoFrancesco Paolo Romano
Francesco Paolo Romano
SGS. Garraffo
S. Garraffo
JSJ. De Sanoit
J. De Sanoit
CMC. Marchetta
C. Marchetta
GPG. Pappalardo
G. Pappalardo