Claudia Caliri

Dr. Claudia Caliri

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2017 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
Francesco Paolo RomanoFrancesco Paolo Romano
Francesco Paolo Romano
CCClaudia Caliri
Claudia Caliri
PNPaolo Nicotra
Paolo Nicotra
SMSandra Di Martino
Sandra Di Martino
LPLighea Pappalardo
Lighea Pappalardo
HSHellen Cristine Santos
Hellen Cristine Santos
A novel mobile macro-XRF (MA-XRF) scanning technique allowing real-time elemental imaging is presented for the investigation of macroscopic paintings. The instrument is based on a microfocus X-ray tube focused with a polycapillary and two SDD detectors operated simultaneously in a time-list event mode. The scanner is based on a three-axis system covering a dimension of 110 × 70 × 20 cm3. MA-XRF scanning is generally performed by positioning samples out of the polycapillary focus with the primary X-ray beam presenting a spot size in the range of hundreds of microns. However, a lateral resolution of up to 25 μm can be achieved at the focus position, allowing complementary use of the scanner for both micro-XRF and macro-XRF mapping. Scanning of artworks is performed with a maximum continuous speed of 100 mm s−1. The full area is covered in 4.3 h in the case of final images presenting a 500 μm pixel size (i.e., corresponding to a dwell time per pixel of 5 ms). The system is controlled with a custom developed control unit (CU) including a graphical user interface (GUI) programmed in Labview for real-time control of all sensors in the scanner and for real-time elaboration of X-ray data. X-ray spectra are processed during the scanning by the least square fast fitting procedure developed in PyMCa and integrated in the system. Up to 7000 fitted spectra per second are possible. A number of editing, processing and mathematical tools are available to users in the GUI and can be applied in a live mode to the forming elemental images. The sum spectrum and maximum pixel spectrum are continuously updated. Final images are available at the end of the scanning and, in most of the cases, they are ready for the interpretation.

1 January 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
Andreas - Germanos KarydasAndreas - Germanos Karydas
Andreas - Germanos Karydas
MCMateusz Czyzycki
Mateusz Czyzycki
JLJuan José Leani
Juan José Leani
AMAlessandro Migliori
Alessandro Migliori
JOJános Osán
János Osán
RKRalf Bernd Kaiser
Ralf Bernd Kaiser
The International Atomic Energy Agency (IAEA) jointly with the Elettra Sincrotrone Trieste (EST) operates a multipurpose X-ray spectrometry endstation at the X-ray Fluorescence beamline (10.1L). The facility has been available to external users since the beginning of 2015 through the peer-review process of EST. Using this collaboration framework, the IAEA supports and promotes synchrotron-radiation-based research and training activities for various research groups from the IAEA Member States, especially those who have limited previous experience and resources to access a synchrotron radiation facility. This paper aims to provide a broad overview about various analytical capabilities, intrinsic features and performance figures of the IAEA X-ray spectrometry endstation through the measured results. The IAEA–EST endstation works with monochromatic X-rays in the energy range 3.7–14 keV for the Elettra storage ring operating at 2.0 or 2.4 GeV electron energy. It offers a combination of different advanced analytical probes, e.g. X-ray reflectivity, X-ray absorption fine-structure measurements, grazing-incidence X-ray fluorescence measurements, using different excitation and detection geometries, and thereby supports a comprehensive characterization for different kinds of nanostructured and bulk materials.

4 October 2014 in Analytical Chemistry
Verified
Journal Article
Closed access
Francesco Paolo RomanoFrancesco Paolo Romano
Francesco Paolo Romano
CCClaudia Caliri
Claudia Caliri
LCLuigi Cosentino
Luigi Cosentino
SGSanto Gammino
Santo Gammino
Lorenzo GiuntiniLorenzo Giuntini
Lorenzo Giuntini
FTFrancesco Taccetti
Francesco Taccetti

6 January 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
DMDavid Mascali
David Mascali
GCGiuseppe Castro
Giuseppe Castro
SBSándor Biri
Sándor Biri
RRRichárd Rácz
Richárd Rácz
JPJózsef Pálinkás
József Pálinkás
SGSanto Gammino
Santo Gammino
An experimental campaign aiming to investigate electron cyclotron resonance (ECR) plasma X-ray emission has been recently carried out at the ECRISs—Electron Cyclotron Resonance Ion Sources laboratory of Atomki based on a collaboration between the Debrecen and Catania ECR teams. In a first series, the X-ray spectroscopy was performed through silicon drift detectors and high purity germanium detectors, characterizing the volumetric plasma emission. The on-purpose developed collimation system was suitable for direct plasma density evaluation, performed “on-line” during beam extraction and charge state distribution characterization. A campaign for correlating the plasma density and temperature with the output charge states and the beam intensity for different pumping wave frequencies, different magnetic field profiles, and single-gas/gas-mixing configurations was carried out. The results reveal a surprisingly very good agreement between warm-electron density fluctuations, output beam currents, and the calculated electromagnetic modal density of the plasma chamber. A charge-coupled device camera coupled to a small pin-hole allowing X-ray imaging was installed and numerous X-ray photos were taken in order to study the peculiarities of the ECRIS plasma structure.

1 July 2017 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
PDF file
RRRichard Racz
Richard Racz
DMD Mascali
D Mascali
SBS Biri
S Biri
CCClaudia Caliri
Claudia Caliri
GCGiuseppe Castro
Giuseppe Castro
GTGiuseppe Torrisi
Giuseppe Torrisi
Pinhole and CCD based quasi-optical x-ray imaging technique was applied to investigate the plasma of an electron cyclotron resonance ion source (ECRIS). Spectrally integrated and energy resolved images were taken from an axial perspective. The comparison of integrated images taken of argon plasma highlights the structural changes affected by some ECRIS setting parameters, like strength of the axial magnetic confinement, RF frequency and microwave power. Photon counting analysis gives precise intensity distribution of the x-ray emitted by the argon plasma and by the plasma chamber walls. This advanced technique points out that the spatial positions of the electron losses are strongly determined by the kinetic energy of the electrons themselves to be lost and also shows evidences how strongly the plasma distribution is affected by slight changes in the RF frequency.

6 April 2017 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
PDF file
GCGiuseppe Castro
Giuseppe Castro
DMD Mascali
D Mascali
SGS Gammino
S Gammino
GTGiuseppe Torrisi
Giuseppe Torrisi
FRF P Romano
F P Romano
GSG Sorbello
G Sorbello
Electron cyclotron resonance ion sources (ECRIS) are widely used plasma based machines for the production of intense ion beams in science and industry. The performance of modern devices is limited by the presence of the density cut-off, above which electromagnetic (EM) waves sustaining the plasma are reflected. We hereby discuss the systematic data analysis of electrostatic wave generation in an ECR prototype operating at 3.75 GHz–0.1 THz. In particular, electron Bernstein waves (EBW) have been excited. EBW have already been generated in large-scale plasma devices for thermonuclear fusion purposes. In ion sources where L c ∼ λ RF ( L c being the plasma chamber size and λ RF the pumping wave wavelength) the EM field assumes a modal behaviour; thus both plasma and EM field self-organize so that no optical-like wave launching is possible (i.e. the cavity effect dominates on the optical path). The collected data, however, supported by 3D full-wave simulations, actually demonstrate that a Budden-type X-B conversion scenario can be established above some critical RF power thresholds, operating in an off-ECR regime. The generation and absorption of the EBW has been demonstrated by the presence of three peculiar signatures: along with the establishment of an overdense plasma, generation of supra-thermal electrons and modification (non-linear broadening) of the EM spectrum measured within the plasma have been observed. At the threshold establishing such a heating regime, the collected data provide evidence for a fast rotation of the electron fluid.