Wennan Zhao

Dr. Wennan Zhao

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2014 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Huanfeng ShenHuanfeng Shen
Huanfeng Shen
WZWennan Zhao
Wennan Zhao
Qiangqiang YuanQiangqiang Yuan
Qiangqiang Yuan
Liangpei ZhangLiangpei Zhang
Liangpei Zhang
In this paper, a blind restoration method is presented to remove the blur in remote sensing images. An alternating minimization (AM) framework is employed to simultaneously recover the image and the point spread function (PSF), and an adaptive-norm prior is used to apply different constraints to smooth regions and edges. Moreover, with the use of the knife-edge features in remote sensing images, an automatic knife-edge detection method is used to obtain a good initial PSF for the AM framework. In addition, a no-reference (NR) sharpness index is used to stop the iterations of the AM framework automatically at the best visual quality. Results in both simulated and real data experiments indicate that the proposed AM-KEdge method, which combines the automatic knife-edge detection and the AM framework, is robust, converges quickly, and can stop automatically to obtain satisfactory results.

8 July 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
XZXiaonan Zang
Xiaonan Zang
WZWennan Zhao
Wennan Zhao
JTJennifer Toth
Jennifer Toth
RBREBECCA BASCOM
REBECCA BASCOM
William HigginsWilliam Higgins
William Higgins
The state-of-the-art procedure for examining the lymph nodes in a lung cancer patient involves using an endobronchial ultrasound (EBUS) bronchoscope. The EBUS bronchoscope integrates two modalities into one device: (1) videobronchoscopy, which gives video images of the airway walls; and (2) convex-probe EBUS, which gives 2D fan-shaped views of extraluminal structures situated outside the airways. During the procedure, the physician first employs videobronchoscopy to navigate the device through the airways. Next, upon reaching a given node’s approximate vicinity, the physician probes the airway walls using EBUS to localize the node. Due to the fact that lymph nodes lie beyond the airways, EBUS is essential for confirming a node’s location. Unfortunately, it is well-documented that EBUS is difficult to use. In addition, while new image-guided bronchoscopy systems provide effective guidance for videobronchoscopic navigation, they offer no assistance for guiding EBUS localization. We propose a method for registering a patient’s chest CT scan to live surgical EBUS views, thereby facilitating accurate image-guided EBUS bronchoscopy. The method entails an optimization process that registers CT-based virtual EBUS views to live EBUS probe views. Results using lung cancer patient data show that the method correctly registered 28/28 (100%) lymph nodes scanned by EBUS, with a mean registration time of 3.4 s. In addition, the mean position and direction errors of registered sites were 2.2 mm and 11.8∘, respectively. In addition, sensitivity studies show the method’s robustness to parameter variations. Lastly, we demonstrate the method’s use in an image-guided system designed for guiding both phases of EBUS bronchoscopy.

12 July 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
WZWennan Zhao
Wennan Zhao
DADanish Ahmad
Danish Ahmad
JTJennifer Toth
Jennifer Toth
RBRebecca Bascom
Rebecca Bascom
William HigginsWilliam Higgins
William Higgins
Background/Objective: Accurate disease diagnosis and staging are essential for patients suspected of having lung cancer. The state-of-the-art minimally invasive tools used by physicians to perform these operations are bronchoscopy, for navigating the lung airways, and endobronchial ultrasound (EBUS), for localizing suspect extraluminal cancer lesions. While new image-guided systems enable accurate bronchoscope navigation close to a lesion, no means exists for guiding the final EBUS localization of an extraluminal lesion. We propose an EBUS simulation method to assist with EBUS localization. Methods: The method draws on a patient's chest computed-tomography (CT) scan to model the ultrasound signal propagation through the tissue media. The method, which is suitable for simulating EBUS images for both radial-probe and convex-probe EBUS devices, entails three steps: 1) image preprocessing, which generates a 2D CT equivalent of the EBUS scan plane; 2) EBUS scan-line computation, which models ultrasound transmission to map the CT plane into a preliminary simulated EBUS image; and 3) image post-processing, which increases realism by introducing simulated EBUS imaging effects and artifacts. Results: Results show that the method produces simulated EBUS images that strongly resemble images generated live by a real device and compares favorably to an existing ultrasound simulation method. It also produces images at a rate greater than real time (i.e., $>$ 53 frames/sec). We also demonstrate a successful integration of the method into an image-guided EBUS bronchoscopy system. Conclusion/Significance: The method is effective and practical for procedure planning/preview and follow-on live guidance of EBUS bronchoscopy.

1 March 2025 in Journal of Medical Imaging
Verified
Journal Article
Open access
WZWennan Zhao
Wennan Zhao
TKTrevor Kuhlengel
Trevor Kuhlengel
QCQi Chang
Qi Chang
VDVahid Daneshpajooh
Vahid Daneshpajooh
YHYuxuan He
Yuxuan He
William HigginsWilliam Higgins
William Higgins
PurposeLung cancer remains the leading cause of cancer death. This has brought about a critical need for managing peripheral regions of interest (ROIs) in the lungs, be it for cancer diagnosis, staging, or treatment. The state-of-the-art approach for assessing peripheral ROIs involves bronchoscopy. To perform the procedure, the physician first navigates the bronchoscope to a preplanned airway, aided by an assisted bronchoscopy system. They then confirm an ROI’s specific location and perform the requisite clinical task. Many ROIs, however, are extraluminal and invisible to the bronchoscope’s field of view. For such ROIs, current practice dictates using a supplemental imaging method, such as fluoroscopy, cone-beam computed tomography (CT), or radial endobronchial ultrasound (R-EBUS), to gather additional ROI location information. Unfortunately, fluoroscopy and cone-beam CT require substantial radiation and lengthen procedure time. As an alternative, R-EBUS is a safer real-time option involving no radiation. Regrettably, existing assisted bronchoscopy systems offer no guidance for R-EBUS confirmation, forcing the physician to resort to an unguided guess-and-check approach for R-EBUS probe placement—an approach that can produce R-EBUS placement errors exceeding 30 deg, an error that can result in missing many ROIs. Thus, because of physician skill variations, biopsy success rates using R-EBUS for ROI confirmation have varied greatly from 31% to 80%. This situation obliges the physician to turn to a radiation-based modality to gather sufficient information for ROI confirmation. We propose a two-phase registration method that provides guidance for R-EBUS probe placement.ApproachAfter the physician navigates the bronchoscope to the airway near a target ROI, the two-phase registration method begins by registering a virtual bronchoscope to the real bronchoscope. A virtual 3D R-EBUS probe model is then registered to the real R-EBUS probe shape depicted in the bronchoscopic video using an iterative region-based alignment method drawing on a level-set-based optimization. This synchronizes the guidance system to the target ROI site. The physician can now perform the R-EBUS scan to confirm the ROI.ResultsWe validated the method’s efficacy for localizing extraluminal ROIs with a series of three studies. First, for a controlled phantom study, we observed that the mean accumulated position and direction errors (accounting for both registration phases) were 1.94 mm and 3.74 deg (equivalent to 1.30 mm position error for a 20 mm biopsy needle), respectively. Next, for a live animal study, these errors were 2.81 mm and 4.79 deg (2.41 mm biopsy needle error), respectively. For 100% of the ROIs considered in these two studies, the method enabled visualization of an ROI via R-EBUS in under 3 min per ROI. Finally, initial operating-room tests on lung cancer patients indicated the method’s efficacy, functionality, efficiency, and safety under standard clinical conditions.ConclusionsThe method offers a quick, low-cost, radiation-free approach for examining peripheral extraluminal ROIs using R-EBUS. Although our studies focused on R-EBUS as the supplemental working channel instrument, the proposed method has general applicability to any clinical bronchoscopic task requiring a working channel instrument. Thus, the method has the potential to improve the efficiency and efficacy of bronchoscopic procedures for lung cancer patients.

16 March 2020
Verified
Conference Paper
Closed access
PDF file
WZWennan Zhao
Wennan Zhao
RBREBECCA BASCOM
REBECCA BASCOM
JTJennifer Toth
Jennifer Toth
William HigginsWilliam Higgins
William Higgins
To diagnose peripheral lung tumors, bronchoscopy is recommended for tissue sampling. Because most peripheral target regions of interest reside outside the airways, during bronchoscopy radial probe endobronchial ultrasound (RP-EBUS) is often used to provide extraluminal information and assist in locating biopsy sites. RP-EBUSguided transbronchial needle aspiration (TBNA) has demonstrated its potential over conventional TBNA to improve the diagnostic yield of peripheral pulmonary nodule biopsy. Meanwhile, image-guided bronchoscopy systems have been introduced to enable better planning and navigation. Currently, the physician has to deal with two disconnected imaging domains during live bronchoscopy; i.e., an image-guided system and RP-EBUS. The state-of-the-art image-guided bronchoscopy systems provide no guidance for RP-EBUS and biopsy targeting during live bronchoscopy, which is needed for accurate diagnosis of peripheral pulmonary nodules. To fill this gap, we expand the concept of virtual bronchoscopy (VB) in image-guided bronchoscopy systems and build a virtual RP-EBUS model to simulate the RP-EBUS probe in the computed-tomography (CT)-based virtual chest space. Results with human patient data illustrate the synchronized visualization of the virtual RP-EBUS model with the 3D chest model.