Danish Ahmad

Danish Ahmad

Auto-generated profile, based on publicly available information

Danish Ahmad

Penn State University, College of Medicine, Hershey, Pennsylvania, United States

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
WZWennan Zhao
Wennan Zhao
DADanish Ahmad
Danish Ahmad
JTJennifer Toth
Jennifer Toth
RBRebecca Bascom
Rebecca Bascom
William HigginsWilliam Higgins
William Higgins
Background/Objective: Accurate disease diagnosis and staging are essential for patients suspected of having lung cancer. The state-of-the-art minimally invasive tools used by physicians to perform these operations are bronchoscopy, for navigating the lung airways, and endobronchial ultrasound (EBUS), for localizing suspect extraluminal cancer lesions. While new image-guided systems enable accurate bronchoscope navigation close to a lesion, no means exists for guiding the final EBUS localization of an extraluminal lesion. We propose an EBUS simulation method to assist with EBUS localization. Methods: The method draws on a patient's chest computed-tomography (CT) scan to model the ultrasound signal propagation through the tissue media. The method, which is suitable for simulating EBUS images for both radial-probe and convex-probe EBUS devices, entails three steps: 1) image preprocessing, which generates a 2D CT equivalent of the EBUS scan plane; 2) EBUS scan-line computation, which models ultrasound transmission to map the CT plane into a preliminary simulated EBUS image; and 3) image post-processing, which increases realism by introducing simulated EBUS imaging effects and artifacts. Results: Results show that the method produces simulated EBUS images that strongly resemble images generated live by a real device and compares favorably to an existing ultrasound simulation method. It also produces images at a rate greater than real time (i.e., $>$ 53 frames/sec). We also demonstrate a successful integration of the method into an image-guided EBUS bronchoscopy system. Conclusion/Significance: The method is effective and practical for procedure planning/preview and follow-on live guidance of EBUS bronchoscopy.

7 August 2024 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
QCQi Chang
Qi Chang
DADanish Ahmad
Danish Ahmad
JTJennifer Toth
Jennifer Toth
RBREBECCA BASCOM
REBECCA BASCOM
William HigginsWilliam Higgins
William Higgins
For patients at risk of developing either lung cancer or colorectal cancer, the identification of suspect lesions in endoscopic video is an important procedure. The physician performs an endoscopic exam by navigating an endoscope through the organ of interest, be it the lungs or intestinal tract, and performs a visual inspection of the endoscopic video stream to identify lesions. Unfortunately, this entails a tedious, error-prone search over a lengthy video sequence. We propose a deep learning architecture that enables the real-time detection and segmentation of lesion regions from endoscopic video, with our experiments focused on autofluorescence bronchoscopy (AFB) for the lungs and colonoscopy for the intestinal tract. Our architecture, dubbed ESFPNet, draws on a pretrained Mix Transformer (MiT) encoder and a decoder structure that incorporates a new Efficient Stage-Wise Feature Pyramid (ESFP) to promote accurate lesion segmentation. In comparison to existing deep learning models, the ESFPNet model gave superior lesion segmentation performance for an AFB dataset. It also produced superior segmentation results for three widely used public colonoscopy databases and nearly the best results for two other public colonoscopy databases. In addition, the lightweight ESFPNet architecture requires fewer model parameters and less computation than other competing models, enabling the real-time analysis of input video frames. Overall, these studies point to the combined superior analysis performance and architectural efficiency of the ESFPNet for endoscopic video analysis. Lastly, additional experiments with the public colonoscopy databases demonstrate the learning ability and generalizability of ESFPNet, implying that the model could be effective for region segmentation in other domains.

1 May 2024 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
VDVahid Daneshpajooh
Vahid Daneshpajooh
DADanish Ahmad
Danish Ahmad
JTJennifer Toth
Jennifer Toth
RBREBECCA BASCOM
REBECCA BASCOM
William HigginsWilliam Higgins
William Higgins
PurposeEarly detection of cancer is crucial for lung cancer patients, as it determines disease prognosis. Lung cancer typically starts as bronchial lesions along the airway walls. Recent research has indicated that narrow-band imaging (NBI) bronchoscopy enables more effective bronchial lesion detection than other bronchoscopic modalities. Unfortunately, NBI video can be hard to interpret because physicians currently are forced to perform a time-consuming subjective visual search to detect bronchial lesions in a long airway-exam video. As a result, NBI bronchoscopy is not regularly used in practice. To alleviate this problem, we propose an automatic two-stage real-time method for bronchial lesion detection in NBI video and perform a first-of-its-kind pilot study of the method using NBI airway exam video collected at our institution.ApproachGiven a patient’s NBI video, the first method stage entails a deep-learning-based object detection network coupled with a multiframe abnormality measure to locate candidate lesions on each video frame. The second method stage then draws upon a Siamese network and a Kalman filter to track candidate lesions over multiple frames to arrive at final lesion decisions.ResultsTests drawing on 23 patient NBI airway exam videos indicate that the method can process an incoming video stream at a real-time frame rate, thereby making the method viable for real-time inspection during a live bronchoscopic airway exam. Furthermore, our studies showed a 93% sensitivity and 86% specificity for lesion detection; this compares favorably to a sensitivity and specificity of 80% and 84% achieved over a series of recent pooled clinical studies using the current time-consuming subjective clinical approach.ConclusionThe method shows potential for robust lesion detection in NBI video at a real-time frame rate. Therefore, it could help enable more common use of NBI bronchoscopy for bronchial lesion detection.

1 March 2025 in Journal of Medical Imaging
Verified
Journal Article
Open access
WZWennan Zhao
Wennan Zhao
TKTrevor Kuhlengel
Trevor Kuhlengel
QCQi Chang
Qi Chang
VDVahid Daneshpajooh
Vahid Daneshpajooh
YHYuxuan He
Yuxuan He
William HigginsWilliam Higgins
William Higgins
PurposeLung cancer remains the leading cause of cancer death. This has brought about a critical need for managing peripheral regions of interest (ROIs) in the lungs, be it for cancer diagnosis, staging, or treatment. The state-of-the-art approach for assessing peripheral ROIs involves bronchoscopy. To perform the procedure, the physician first navigates the bronchoscope to a preplanned airway, aided by an assisted bronchoscopy system. They then confirm an ROI’s specific location and perform the requisite clinical task. Many ROIs, however, are extraluminal and invisible to the bronchoscope’s field of view. For such ROIs, current practice dictates using a supplemental imaging method, such as fluoroscopy, cone-beam computed tomography (CT), or radial endobronchial ultrasound (R-EBUS), to gather additional ROI location information. Unfortunately, fluoroscopy and cone-beam CT require substantial radiation and lengthen procedure time. As an alternative, R-EBUS is a safer real-time option involving no radiation. Regrettably, existing assisted bronchoscopy systems offer no guidance for R-EBUS confirmation, forcing the physician to resort to an unguided guess-and-check approach for R-EBUS probe placement—an approach that can produce R-EBUS placement errors exceeding 30 deg, an error that can result in missing many ROIs. Thus, because of physician skill variations, biopsy success rates using R-EBUS for ROI confirmation have varied greatly from 31% to 80%. This situation obliges the physician to turn to a radiation-based modality to gather sufficient information for ROI confirmation. We propose a two-phase registration method that provides guidance for R-EBUS probe placement.ApproachAfter the physician navigates the bronchoscope to the airway near a target ROI, the two-phase registration method begins by registering a virtual bronchoscope to the real bronchoscope. A virtual 3D R-EBUS probe model is then registered to the real R-EBUS probe shape depicted in the bronchoscopic video using an iterative region-based alignment method drawing on a level-set-based optimization. This synchronizes the guidance system to the target ROI site. The physician can now perform the R-EBUS scan to confirm the ROI.ResultsWe validated the method’s efficacy for localizing extraluminal ROIs with a series of three studies. First, for a controlled phantom study, we observed that the mean accumulated position and direction errors (accounting for both registration phases) were 1.94 mm and 3.74 deg (equivalent to 1.30 mm position error for a 20 mm biopsy needle), respectively. Next, for a live animal study, these errors were 2.81 mm and 4.79 deg (2.41 mm biopsy needle error), respectively. For 100% of the ROIs considered in these two studies, the method enabled visualization of an ROI via R-EBUS in under 3 min per ROI. Finally, initial operating-room tests on lung cancer patients indicated the method’s efficacy, functionality, efficiency, and safety under standard clinical conditions.ConclusionsThe method offers a quick, low-cost, radiation-free approach for examining peripheral extraluminal ROIs using R-EBUS. Although our studies focused on R-EBUS as the supplemental working channel instrument, the proposed method has general applicability to any clinical bronchoscopic task requiring a working channel instrument. Thus, the method has the potential to improve the efficiency and efficacy of bronchoscopic procedures for lung cancer patients.