You Seon Song

Dr. You Seon Song

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2019 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
YCYoung Jin Choi
Young Jin Choi
ILIn Sook Lee
In Sook Lee
YSYou Seon Song
You Seon Song
JKJeung Il Kim
Jeung Il Kim
KCKyung‐Un Choi
Kyung‐Un Choi
JSJong Woon Song
Jong Woon Song

1 May 2020 in Journal of Korean Neurosurgical Society
Verified
Journal Article
Open access
PDF file
JLJung Hwan Lee
Jung Hwan Lee
IHIn Ho Han
In Ho Han
DKDong Hwan Kim
Dong Hwan Kim
SYSeunghan Yu
Seunghan Yu
ILIn Sook Lee
In Sook Lee
Hakil KimHakil Kim
Hakil Kim
To generate synthetic spine magnetic resonance (MR) images from spine computed tomography (CT) using generative adversarial networks (GANs), as well as to determine the similarities between synthesized and real MR images. GANs were trained to transform spine CT image slices into spine magnetic resonance T2 weighted (MRT2) axial image slices by combining adversarial loss and voxel-wise loss. Experiments were performed using 280 pairs of lumbar spine CT scans and MRT2 images. The MRT2 images were then synthesized from 15 other spine CT scans. To evaluate whether the synthetic MR images were realistic, two radiologists, two spine surgeons, and two residents blindly classified the real and synthetic MRT2 images. Two experienced radiologists then evaluated the similarities between subdivisions of the real and synthetic MRT2 images. Quantitative analysis of the synthetic MRT2 images was performed using the mean absolute error (MAE) and peak signal-to-noise ratio (PSNR). The mean overall similarity of the synthetic MRT2 images evaluated by radiologists was 80.2%. In the blind classification of the real MRT2 images, the failure rate ranged from 0% to 40%. The MAE value of each image ranged from 13.75 to 34.24 pixels (mean, 21.19 pixels), and the PSNR of each image ranged from 61.96 to 68.16 dB (mean, 64.92 dB). This was the first study to apply GANs to synthesize spine MR images from CT images. Despite the small dataset of 280 pairs, the synthetic MR images were relatively well implemented. Synthesis of medical images using GANs is a new paradigm of artificial intelligence application in medical imaging. We expect that synthesis of MR images from spine CT images using GANs will improve the diagnostic usefulness of CT. To better inform the clinical applications of this technique, further studies are needed involving a large dataset, a variety of pathologies, and other MR sequence of the lumbar spine.

15 July 2022 in Medicina
Verified
Journal Article
Open access
PDF file
JYJeong-A Yeom
Jeong-A Yeom
KKKi-Uk Kim
Ki-Uk Kim
MHMinhee Hwang
Minhee Hwang
JLJi-Won Lee
Ji-Won Lee
KKKun-Il Kim
Kun-Il Kim
YJYeon Joo Jeong
Yeon Joo Jeong
Background and Objectives: Although reducing the radiation dose level is important during diagnostic computed tomography (CT) applications, effective image quality enhancement strategies are crucial to compensate for the degradation that is caused by a dose reduction. We performed this prospective study to quantify emphysema on ultra-low-dose CT images that were reconstructed using deep learning-based image reconstruction (DLIR) algorithms, and compared and evaluated the accuracies of DLIR algorithms versus standard-dose CT. Materials and Methods: A total of 32 patients were prospectively enrolled, and all underwent standard-dose and ultra-low-dose (120 kVp; CTDIvol < 0.7 mGy) chest CT scans at the same time in a single examination. A total of six image datasets (filtered back projection (FBP) for standard-dose CT, and FBP, adaptive statistical iterative reconstruction (ASIR-V) 50%, DLIR-low, DLIR-medium, DLIR-high for ultra-low-dose CT) were reconstructed for each patient. Image noise values, emphysema indices, total lung volumes, and mean lung attenuations were measured in the six image datasets and compared (one-way repeated measures ANOVA). Results: The mean effective doses for standard-dose and ultra-low-dose CT scans were 3.43 ± 0.57 mSv and 0.39 ± 0.03 mSv, respectively (p < 0.001). The total lung volume and mean lung attenuation of five image datasets of ultra-low-dose CT scans, emphysema indices of ultra-low-dose CT scans reconstructed using ASIR-V 50 or DLIR-low, and the image noise of ultra-low-dose CT scans that were reconstructed using DLIR-low were not different from those of standard-dose CT scans. Conclusions: Ultra-low-dose CT images that were reconstructed using DLIR-low were found to be useful for emphysema quantification at a radiation dose of only 11% of that required for standard-dose CT.

1 January 2025 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
ILIn Sook Lee
In Sook Lee
YSYou Seon Song
You Seon Song
YCYoung Jin Choi
Young Jin Choi
JKJeung Il Kim
Jeung Il Kim
KCKyung Un Choi
Kyung Un Choi
MNMarcel Dominik Nickel
Marcel Dominik Nickel
Lee IS, et al. Korean J Radiol. 2025 Nov;26(11):1054-1074. https://doi.org/10.3348/kjr.2025.0643

1 April 2021 in European Journal of Radiology
Verified
Journal Article
Closed access
KNKyoung Hyup Nam
Kyoung Hyup Nam
ILIn Sook Lee
In Sook Lee
YSYou Seon Song
You Seon Song
IHIn Ho Han
In Ho Han
DKDong Hwan Kim
Dong Hwan Kim

26 August 2022 in World Journal of Clinical Cases
Verified
Journal Article
Open access
JYJeong A Yeom
Jeong A Yeom
YSYou Seon Song
You Seon Song
ILIn Sook Lee
In Sook Lee
IHIn Ho Han
In Ho Han
KCKyung Un Choi
Kyung Un Choi
A malignant melanotic nerve sheath tumor (MMNST), previously known as a melanotic schwannoma, is a rare variant of a peripheral nerve sheath tumor composed of Schwann cells with melanotic differentiation. Only a few reports of spinal MMNST have been reported. In the first case, a 58-year-old woman presented with a history of low back pain and paresthesia. Magnetic resonance imaging (MRI) and computed tomography (CT) of the lumbar spine revealed an intradural extramedullary mass lesion with amorphous linear calcification. Complete tumor resection was performed and histological examination revealed a psammomatous melanotic schwannoma. In the second case, a 72-year-old man presented with low back pain and paresthesia. MRI of the thoracolumbar spine revealed an intramedullary mass lesion at the T11 vertebral body level. The mass lesion was hypointense on T2WI and hyperintense on T1WI. Tumor resection was performed and the histologic result was melanotic schwannoma. MMNST should be considered in the differential diagnosis when calcification or melanin is seen in an intradural spinal tumor.