While the biomechanical effects of exoskeletons are well studied, research about potential side-effects and adverse events are limited. The aim of this systematic review was to provide an overview of the side-effects and adverse events on shoulder- and back-support exoskeletons during work tasks. Four in-field studies and 32 laboratory studies were included in this review, reporting on n = 18 shoulder exoskeletons, n = 9 back exoskeletons, n = 1 full body with a supernumerary arm, and n = 1 combination of shoulder and back exoskeleton. The most frequent side-effect reported is discomfort (n = 30), followed by a limited usability of the exoskeleton (n = 16). Other identified side-effects and adverse events were changes in muscle activity, mobility, task performance, balance and posture, neurovascular supply, gait parameters and precision. An incorrect fit of the exoskeleton and the decreased degrees of freedom are most often reported as causes of these side-effects. Two studies did not find any side-effects. This review also showed that there are differences in the occurrence of side-effects in gender, age, and physical fitness. Most studies (89%) were conducted in a laboratory setting. Most studies (97%) measured short-term effects only. Psychological and social side-effects or adverse events were not reported. Side-effects and adverse events for active exoskeletons were understudied (n = 4). It was concluded that the evidence for side-effects and adverse events is limited. If available, it mainly consists of reports of mild discomfort and limited usability. Generalisation is limited because studies were conducted in lab settings and measured short term only, and most participants were young male workers.
Context:Plantar fasciitis is one of the most common foot injuries. Several mechanical treatment options, including shoe inserts, ankle-foot orthoses, tape, and shoes are used to relieve the symptoms of plantar fasciitis.Objectives:To investigate the effectiveness of mechanical treatment in the management of plantar fasciitis.Evidence Acquisition:The review was reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis statement. A systematic search was performed in PubMed, CINAHL, Embase, and Cochrane up to March 8, 2018. Two independent reviewers screened eligible articles and assessed risk of bias using the Cochrane Collaboration’s risk of bias tool.Evidence Synthesis:A total of 43 articles were included in the study, evaluating 2837 patients. Comparisons were made between no treatment and treatment with insoles, tape, ankle-foot orthoses including night splints and shoes. Tape, ankle-foot orthoses, and shoes were also compared with insoles. Follow-up ranged from 3 to 5 days to 12 months. Cointerventions were present in 26 studies.Conclusions:Mechanical treatment can be beneficial in relieving symptoms related to plantar fasciitis. Contoured full-length insoles are more effective in relieving symptoms related to plantar fasciitis than heel cups. Combining night splints or rocker shoes with insoles enhances improvement in pain relief and function compared with rocker shoes, night splints, or insoles alone. Taping is an effective short-term treatment. Future studies should aim to improve methodological quality using blinding, allocation concealment, avoid cointerventions, and use biomechanical measures of treatment effects.
After initial clubfoot correction through Ponseti treatment, recurrence rates range from 26% to 48%. Even though various factors have been associated with increased recurrence risk, systematic assessments of the prognostic capacity of recurrence risk factors and their clinical relevance are lacking. Therefore we assessed clinically relevant prognostic factors for recurrent idiopathic clubfoot deformity after initial correction through Ponseti treatment. PubMed, Embase, Cinahl, and Web of Science were systematically searched for studies investigating the association between clinically relevant factors and recurrence rates. Prognostic factors were qualitatively assessed and included in the meta-analysis if ≥ 2 studies investigated the same factor and methods were comparable. 34 articles were included in the qualitative synthesis, of which 22 were also included in the meta-analysis. Meta-analysis revealed that poor evertor muscle activity (OR = 255, 95% CI 30–2,190), brace non-compliance (OR = 10, CI 5–21), no additional stretching (OR = 31, CI 10–101), more casts (OR = 3.5, CI 1.6–7.8), lower education level of parents (OR = 1.8, CI 1.2–2.6), non-marital status of parents (OR = 1.8, CI 1.1–3.0), and higher Dimeglio scores (OR = 1.9, CI 1.2–3.3) were associated with higher recurrence rates. Brace non-compliance and poor evertor muscle activity have been identified as main recurrence risk factors and are therefore important to be closely monitored during clinical follow-up of clubfoot patients. Adding additional stretching during the bracing protocol might be promising in the quest to prevent relapse, but scientific evidence for clear clinical treatment recommendations is still limited.
Plantar fasciitis is a frequently occurring overuse injury of the foot. Shoes with a stiff rocker profile are a commonly prescribed treatment modality used to alleviate complaints associated with plantar fasciitis. In rocker shoes the apex position was moved proximally as compared to normal shoes, limiting the progression of the ground reaction forces (GRF) and peak plantarflexion moments during gait. A stiff sole minimizes dorsiflexion of the toes. The aim of this study was to investigate whether the biomechanical effects of rocker shoes lead to minimization of plantar aponeurosis (PA) strain during gait in patients with plantar fasciitis and in healthy young adults. 8 patients with plantar fasciitis (1 male, 7 females; mean age 55.0 ± 8.4 years) and 8 healthy young adults (8 females; mean age 24.1 ± 1.6 years) participated in the study. Each participant walked for 1 minute on an instrumented treadmill while wearing consecutively in random order shoes with a normal apex position (61.2 ± 2.8% apex) with flexible insole (FN), normal apex position with stiff insole (SN), proximal apex position (56.1 ± 2.6% apex) with flexible insole (FR) and proximal apex position with stiff insole (SR). Marker position data of the foot and lower leg and GRF were recorded. An OpenSim foot model was used to compute the change in PA length based on changes in foot segment positions during gait. The changes in PA length due to increases in Achilles tendon forces were computed based on previous data of a cadaver study. PA strain computed from both methods was not statistically different between shoe conditions. Peak Achilles tendon force, peak first metatarsophalangeal (MTP1) joint angle and peak plantarflexion moment were significantly lower when walking with the rocker shoe with a proximal apex position and a stiff insole for all subjects (p<.05). Changes in Achilles tendon forces during gait accounted for 65 ± 2% of the total PA strain. Rocker shoes with a stiff insole reduce peak dorsiflexion angles of the toes and plantar flexion moments, but not PA strain because the effects of a proximal apex position and stiff insole do not occur at the same time, but independently affect PA strain at 80–90% and 90–100% of the stance phase. Rocker shoes with an apex position of ~56% are insufficient to significantly reduce peak PA strain values in patients with plantar fasciitis and healthy young adults.
14 March 2017 in European Journal of Applied Physiology
Our ability to flexibly coordinate the available degrees of freedom allows us to perform activities of daily living under various task constraints. Healthy old adults exhibit subclinical peripheral and central nervous system dysfunctions, possibly compromising the flexibility in inter-joint coordination during voluntary movements and the ability to adapt to varying task constraints.
Surgeons are at high risk for developing musculoskeletal symptoms (MSS), like neck and back pain. Quantitative analysis of 3D neck and trunk movements during surgery can help to develop preventive devices such as exoskeletons. Inertial Measurement Units (IMU) and markerless motion capture methods are allowed in the operating room (OR) and are a good alternative for bulky optoelectronic systems. We aim to validate IMU and markerless methods against an optoelectronic system during a simulated surgery task. Intraclass correlation coefficient (ICC (2,1)), root mean square error (RMSE), range of motion (ROM) difference and Bland–Altman plots were used for evaluating both methods. The IMU-based motion analysis showed good-to-excellent (ICC 0.80–0.97) agreement with the gold standard within 2.3 to 3.9 degrees RMSE accuracy during simulated surgery tasks. The markerless method shows 5.5 to 8.7 degrees RMSE accuracy (ICC 0.31–0.70). Therefore, the IMU method is recommended over the markerless motion capture.