Ce Zhang

Mr. Ce Zhang

University Medical Center Groningen, Groningen, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CZCe Zhang
Ce Zhang
CGChristian Greve
Christian Greve
GVGijsbertus Jacob Verkerke
Gijsbertus Jacob Verkerke
CRCharissa Roossien
Charissa Roossien
HHHan Houdijk
Han Houdijk
JHJuha Hijmans
Juha Hijmans
Surgeons are at high risk for developing musculoskeletal symptoms (MSS), like neck and back pain. Quantitative analysis of 3D neck and trunk movements during surgery can help to develop preventive devices such as exoskeletons. Inertial Measurement Units (IMU) and markerless motion capture methods are allowed in the operating room (OR) and are a good alternative for bulky optoelectronic systems. We aim to validate IMU and markerless methods against an optoelectronic system during a simulated surgery task. Intraclass correlation coefficient (ICC (2,1)), root mean square error (RMSE), range of motion (ROM) difference and Bland–Altman plots were used for evaluating both methods. The IMU-based motion analysis showed good-to-excellent (ICC 0.80–0.97) agreement with the gold standard within 2.3 to 3.9 degrees RMSE accuracy during simulated surgery tasks. The markerless method shows 5.5 to 8.7 degrees RMSE accuracy (ICC 0.31–0.70). Therefore, the IMU method is recommended over the markerless motion capture.

5 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
CZCe Zhang
Ce Zhang
CRCharissa Roossien
Charissa Roossien
GVGijsbertus Jacob Verkerke
Gijsbertus Jacob Verkerke
HHHan Houdijk
Han Houdijk
JHJuha Hijmans
Juha Hijmans
CGChristian Greve
Christian Greve
The prevalence of musculoskeletal symptoms (MSS) like neck and back pain is high among open-surgery surgeons. Prolonged working in the same posture and unfavourable postures are biomechanical risk factors for developing MSS. Ergonomic devices such as exoskeletons are possible solutions that can reduce muscle and joint load. To design effective exoskeletons for surgeons, one needs to quantify which neck and trunk postures are seen and how much support during actual surgery is required. Hence, this study aimed to establish the biomechanical profile of neck and trunk postures and neck and lumbar joint loads during open surgery (training). Eight surgical trainees volunteered to participate in this research. Neck and trunk segment orientations were recorded using an inertial measurement unit (IMU) system during open surgery (training). Neck and lumbar joint kinematics, joint moments and compression forces were computed using OpenSim modelling software and a musculoskeletal model. Histograms were used to illustrate the joint angle and load distribution of the neck and lumbar joints over time. During open surgery, the neck flexion angle was 71.6% of the total duration in the range of 10~40 degrees, and lumbar flexion was 68.9% of the duration in the range of 10~30 degrees. The normalized neck and lumbar flexion moments were 53.8% and 35.5% of the time in the range of 0.04~0.06 Nm/kg and 0.4~0.6 Nm/kg, respectively. Furthermore, the neck and lumbar compression forces were 32.9% and 38.2% of the time in the range of 2.0~2.5 N/kg and 15~20 N/kg, respectively. In contrast to exoskeletons used for heavy lifting tasks, exoskeletons designed for surgeons exhibit lower support torque requirements while additional degrees of freedom (DOF) are needed to accommodate combinations of neck and trunk postures.

21 December 2024 in Journal of Bionic Engineering
Verified
Journal Article
Closed access
PDF file
CZCe Zhang
Ce Zhang
JHJuha M. Hijmans
Juha M. Hijmans
CGChristian Greve
Christian Greve
HHHan Houdijk
Han Houdijk
GVGijsbertus Jacob Verkerke
Gijsbertus Jacob Verkerke
CRCharlotte Christina Roossien
Charlotte Christina Roossien

1 December 2019 in Defence Technology
Verified
Journal Article
Open access
CZCe Zhang
Ce Zhang
XZXin Zhao
Xin Zhao
ZMZonglai Mo
Zonglai Mo
ZGZhuoyu Guo
Zhuoyu Guo
JLJun Li
Jun Li