Muhammad  Talha

Dr. Muhammad Talha


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2017 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
FAFurqan Asghar
Furqan Asghar
MTMuhammad Talha
Muhammad Talha
SKSung Ho Kim
Sung Ho Kim

30 May 2017 in Energies
Verified
Journal Article
Open access
PDF file
FAFurqan Asghar
Furqan Asghar
MTMuhammad Talha
Muhammad Talha
SKSung Ho Kim
Sung Ho Kim
The microgrid (MG) concept is attracting considerable attention as a solution to energy deficiencies, especially in remote areas, but the intermittent nature of renewable sources and varying loads cause many control problems and thereby affect the quality of power within a microgrid operating in standalone mode. This might cause large frequency and voltage deviations in the system due to unpredictable output power fluctuations. Furthermore, without any main grid support, it is more complex to control and manage the system. In past, droop control and various other coordination control strategies have been presented to stabilize the microgrid frequency and voltages, but in order to utilize the available resources up to their maximum capacity in a positive way, new and robust control mechanisms are required. In this paper, a standalone microgrid is presented, which integrates renewable energy-based distributed generations and local loads. A fuzzy logic-based intelligent control technique is proposed to maintain the frequency and DC (direct current)-link voltage stability for sudden changes in load or generation power. Also from a frequency control perspective, a battery energy storage system (BESS) is suggested as a replacement for a synchronous generator to stabilize the nominal system frequency as a synchronous generator is unable to operate at its maximum efficiency while being controlled for stabilization purposes. Likewise, a super capacitor (SC) and BESS is used to stabilize DC bus voltages even though maximum possible energy is being extracted from renewable generated sources using maximum power point tracking. This newly proposed control method proves to be effective by reducing transient time, minimizing the frequency deviations, maintaining voltages even though maximum power point tracking is working and preventing generators from exceeding their power ratings during disturbances. However, due to the BESS limited capacity, load switching (load shedding scheme) as last option is also introduced in this paper. Simulation results prove the effectiveness of the proposed control strategy from both frequency and voltage perspectives.

6 June 2018 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
MTMuhammad Talha
Muhammad Talha
FAFurqan Asghar
Furqan Asghar
Ali RohanAli Rohan
Ali Rohan
MRMohamed Rabah
Mohamed Rabah
SKSung Ho Kim
Sung Ho Kim

15 February 2019 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
Ali RohanAli Rohan
Ali Rohan
MRMohamed Rabah
Mohamed Rabah
FAFurqan Asghar
Furqan Asghar
MTMuhammad Talha
Muhammad Talha
SKSung-Ho Kim
Sung-Ho Kim

26 March 2018 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
MTMuhammad Talha
Muhammad Talha
FAFurqan Asghar
Furqan Asghar
SKSung Ho Kim
Sung Ho Kim

10 November 2016 in Journal of Control Science and Engineering
Verified
Journal Article
Open access
PDF file
FAFurqan Asghar
Furqan Asghar
MTMuhammad Talha
Muhammad Talha
SKSung Ho Kim
Sung Ho Kim
Recently, electrical drives generally associate inverter and induction machine. Therefore, inverter must be taken into consideration along with induction motor in order to provide a relevant and efficient diagnosis of these systems. Various faults in inverter may influence the system operation by unexpected maintenance, which increases the cost factor and reduces overall efficiency. In this paper, fault detection and diagnosis based on features extraction and neural network technique for three-phase inverter is presented. Basic purpose of this fault detection and diagnosis system is to detect single or multiple faults efficiently. Several features are extracted from the Clarke transformed output current and used in neural network as input for fault detection and diagnosis. Hence, some simulation study as well as hardware implementation and experimentation is carried out to verify the feasibility of the proposed scheme. Results show that the designed system not only detects faults easily, but also can effectively differentiate between multiple faults. These results prove the credibility and show the satisfactory performance of designed system. Results prove the supremacy of designed system over previous feature extraction fault systems as it can detect and diagnose faults in a single cycle as compared to previous multicycles detection with high accuracy.