TUCHEN HUANG

Dr. TUCHEN HUANG

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2022 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Open access
YZYan Zhang
Yan Zhang
QFQibin Fu
Qibin Fu
THTUCHEN HUANG
TUCHEN HUANG
YLYang Liu
Yang Liu
GCGengming Chen
Gengming Chen
SLShaopeng Lin
Shaopeng Lin
Radiotherapy is an important treatment modality for cancer patients. Ionizing radiation kills cancer cells by inducing DNA damage. However, it remains unclear how this process affects the biomechanical properties of cells and how cellular mechanics affect DNA damage and repair. In this study, the effects of ionizing radiation on cell mechanics were investigated by precisely measuring the compressibility of cells in suspension using an in-house developed microfluidic device. We found that cell compressibility significantly increased after irradiation, depending on cell type and radiation dose. Radiation-induced DNA damage response (DDR) is an important process that alters cell mechanics, and this association was confirmed experimentally by inhibiting the DDR process. Furthermore, the mechanisms involved in changes in cell compressibility were investigated from the perspective of the nucleus and cytoplasm. Experiments showed that radiation reduced H3K9me3 staining intensity but had no effect on F-actin. This suggested that chromatin decondensation caused by radiation-induced DDR is the primary cause of changes in cell compressibility after radiation. The effects of cell mechanics on radiation-induced DNA damage were also investigated. The addition of blebbistatin reduced cytoskeletal forces on the nucleus, which resulted in a reduction in radiation-induced DNA damage. Collectively, this study elucidated reciprocal mechanisms of radiation-induced DNA damage and cell mechanics.

1 May 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
THTUCHEN HUANG
TUCHEN HUANG
ZZZhibo Zhang
Zhibo Zhang

2 July 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
FSFengzhao Shen
Fengzhao Shen
YPYongyu Pan
Yongyu Pan
QFQibin Fu
Qibin Fu
SLShaopeng Lin
Shaopeng Lin
THTUCHEN HUANG
TUCHEN HUANG
WWWei Wang
Wei Wang

21 September 2024 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
QFQibin Fu
Qibin Fu
YZYan Zhang
Yan Zhang
YWYu-Cheng Wang
Yu-Cheng Wang
THTUCHEN HUANG
TUCHEN HUANG
HZHong-Yu Zhu
Hong-Yu Zhu
XDXiaowu Deng
Xiaowu Deng

31 July 2022 in Crystals
Verified
Journal Article
Open access
PDF file
FSFengzhao Shen
Fengzhao Shen
QFQibin Fu
Qibin Fu
THTUCHEN HUANG
TUCHEN HUANG
WWWei Wang
Wei Wang
Sodium iodide crystal co-doped with thallium and lithium is a promising scintillator with wide application prospects for dual gamma neutron detection. In this study, a compact gamma/neutron detector was developed based on 2-inch NaI(Tl+Li) (NaIL) scintillator readout with 8 × 8 silicon photomultiplier (SiPM) array. Dedicated transimpedance amplifier circuit was developed for the SiPM array. The energy resolution and response linearity with the SiPM array were evaluated and compared to those obtained with photomultiplier tube (PMT) readout. The energy resolution for 661.6 keV gamma rays was measured as 7.0% and 6.5% with SiPM array and PMT, respectively. The linear response of the SiPM array is almost the same as that of the PMT in the energy range up to ~4 MeV. Neutron and gamma pulse shape discrimination was evaluated by acquiring the pulse waveforms with a digitizer (12 bit/250 MSPS) and off-line analysis. The best figure of merit (FOM) was measured as 3.75 for the SiPM array with optimized parameters, close to the performance measured with PMT (FOM = 4.07). The experimental results show that the NaIL scintillator readout with SiPM array exhibit energy resolution equivalent to NaI(Tl) gamma detectors and excellent neutron/gamma discrimination, making it especially suitable for compact devices requiring gamma and neutron dual detection capabilities.

Verified
Journal Article
Open access
PDF file
YZYan Zhang
Yan Zhang
ZZZiang Zhang
Ziang Zhang
DZDongbang Zheng
Dongbang Zheng
THTUCHEN HUANG
TUCHEN HUANG
QFQibin Fu
Qibin Fu
YLYang Liu
Yang Liu
Circulating tumor cells (CTCs) play an important role in the prognosis and efficacy evaluation of metastatic tumors. Since CTCs are present in very low concentrations in the blood and the phenotype is dynamically changing, it is a great challenge to achieve efficient separation while maintaining their viability. In this work, we designed an acoustofluidic microdevice for CTCs separation based on the differences in cell physical properties of size and compressibility. Efficient separation can be achieved with only one piece of piezoceramic working on alternating frequency mode. The separation principle was simulated by numerical calculation. Cancer cells from different tumor types were separated from peripheral blood mononuclear cells (PBMCs), with capture efficiency higher than 94% and a contamination rate of about 1% was obtained. Furthermore, this method was validated to have no negative effect on the viability of the separated cells. Finally, blood samples from patients with different cancer types and stages were tested, with measured concentrations of 36–166 CTCs per milliliter. Effective separation was achieved even when the size of CTCs is similar to that of PBMCs, which has the prospect of clinical application in cancer diagnosis and efficacy evaluation.