Yang Liu

Yang Liu

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
DHDeny Hartono
Deny Hartono
YLYang Liu
Yang Liu
PTPei Lin Tan
Pei Lin Tan
XTXin Yi Sherlene Then
Xin Yi Sherlene Then
LYLin-Yue Lanry Yung
Lin-Yue Lanry Yung
KLKian Meng Lim
Kian Meng Lim
Measurements of mechanical properties of biological cells are of great importance because changes in these properties can be strongly associated with the progression of cell differentiation and cell diseases. Although state of the art methods, such as atomic force microscopy, optical tweezers and micropipette aspiration, have been widely used to measure the mechanical properties of biological cells, all these methods involve direct contact with the cell and the measurements could be affected by the contact or any local deformation. In addition, all these methods typically deduced the Young's modulus of the cells based on their measurements. Herein, we report a new method for fast and direct measurement of the compressibility or bulk modulus of various cell lines on a microchip. In this method, the whole cell is exposed to acoustic radiation force without any direct contact. The method exploits the formation of an acoustic standing wave within a straight microchannel. When the polystyrene beads and cells are introduced into the channel, the acoustic radiation force moves them to the acoustic pressure node and the movement speed is dependent on the compressibility. By fitting the experimental and theoretical trajectories of the beads and the cells, the compressibility of the cells can be obtained. We find that the compressibility of various cancer cells (MCF-7: 4.22 ± 0.19 × 10−10Pa−1, HEPG2: 4.28 ± 0.12 × 10−10Pa−1, HT-29: 4.04 ± 0.16 × 10−10Pa−1) is higher than that of normal breast cells (3.77 ± 0.09 × 10−10Pa−1) and fibroblast cells (3.78 ± 0.17 × 10−10Pa−1). This work demonstrates a novel acoustic-based method for on-chip measurements of cell compressibility, complementing existing methods for measuring the mechanical properties of biological cells.

8 August 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YLYang Liu
Yang Liu
KLKian Meng Lim
Kian Meng Lim
We present a new method for separation of micro-sized constituents with positive acoustic contrast factors in a microfluidic channel using ultrasound. The ultrasound field is switched between the first and third resonant modes of the fluid channel, and the suspended constituents are separated onto the side and center pressure nodal lines according to their sizes or acoustic contrast factors. Initial hydrodynamic focusing of the constituents within a region of the channel near to the side nodal line is a crucial step in this separation method. This new method is shown to provide a novel “parallel-stream” separation of two species of particles with good robustness. Prior numerical simulations provide essential information on this operating region and also the voltage cycle to be applied to the ultrasonic actuators for optimal separation. Experiments were conducted using a prototype of the design with polystyrene microspheres of different sizes to demonstrate the efficiency and robustness of the separation process.

8 November 2021 in Biomicrofluidics
Verified
Journal Article
Open access
PDF file
QFQibin Fu
Qibin Fu
YZYan Zhang
Yan Zhang
THTuchen Huang
Tuchen Huang
YLYing Liang
Ying Liang
YLYang Liu
Yang Liu
Epithelial–mesenchymal transition (EMT) confers migratory and invasiveness abilities on cancer cells, as well as leading to changes in biomechanical properties and cytoskeletal structure. Cell mechanical properties are considered to be promising label-free markers for diagnosis of cancer metastasis. In this work, cell compressibility, a novel and important parameter of cell mechanical properties, was measured directly and quickly using a specially designed acoustofluidic microdevice. The compressibilities of cells with different metastatic potentials were investigated. Based on a comparison of the measurement results, non-metastatic cells exhibited lower compressibility than metastatic cells. The correlation between cell compressibility and EMT status was further studied; the results showed that the acquisition of mesenchymal status was accompanied by an increase in cell compressibility. These findings imply strong correlations among cell compressibility, EMT status, and invasiveness. Therefore, cell compressibility represents a novel biomechanical marker for evaluating malignant transformation and metastasis of cancer.

1 March 2012 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
YLYang Liu
Yang Liu
DHDeny Hartono
Deny Hartono
KLKian Meng Lim
Kian Meng Lim
This paper presents a two-stream microfluidic system for transporting cells or micro-sized particles from one fluid stream to another by acoustophoresis. The two fluid streams, one being the original suspension and the other being the destination fluid, flow parallel to each other in a microchannel. Using a half-wave acoustic standing wave across the channel width, cells or particles with positive acoustic contrast factors are moved to the destination fluid where the pressure nodal line lies. By controlling the relative flow rate of the two fluid streams, the pressure nodal line can be maintained at a specific offset from the fluid interface within the destination fluid. Using this transportation method, particles or cells of different sizes and mechanical properties can be separated. The cells experiencing a larger acoustic radiation force are separated and transported from the original suspension to the destination fluid stream. The other particles or cells experiencing a smaller acoustic radiation force continue flowing in the original solution. Experiments were conducted to demonstrate the effective separation of polystyrene microbeads of different sizes (3 μm and 10 μm) and waterborne parasites (Giardia lamblia and Cryptosporidium parvum). Diffusion occurs between the two miscible fluids, but it was found to have little effects on the transport and separation process, even when the two fluids have different density and speed of sound.

16 September 2022 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
HHHao Hu
Hao Hu
JWJiayue Wang
Jiayue Wang
ACAi Chen
Ai Chen
YLYang Liu
Yang Liu

Verified
Journal Article
Open access
PDF file
YZYan Zhang
Yan Zhang
ZZZiang Zhang
Ziang Zhang
DZDongbang Zheng
Dongbang Zheng
THTUCHEN HUANG
TUCHEN HUANG
QFQibin Fu
Qibin Fu
YLYang Liu
Yang Liu
Circulating tumor cells (CTCs) play an important role in the prognosis and efficacy evaluation of metastatic tumors. Since CTCs are present in very low concentrations in the blood and the phenotype is dynamically changing, it is a great challenge to achieve efficient separation while maintaining their viability. In this work, we designed an acoustofluidic microdevice for CTCs separation based on the differences in cell physical properties of size and compressibility. Efficient separation can be achieved with only one piece of piezoceramic working on alternating frequency mode. The separation principle was simulated by numerical calculation. Cancer cells from different tumor types were separated from peripheral blood mononuclear cells (PBMCs), with capture efficiency higher than 94% and a contamination rate of about 1% was obtained. Furthermore, this method was validated to have no negative effect on the viability of the separated cells. Finally, blood samples from patients with different cancer types and stages were tested, with measured concentrations of 36–166 CTCs per milliliter. Effective separation was achieved even when the size of CTCs is similar to that of PBMCs, which has the prospect of clinical application in cancer diagnosis and efficacy evaluation.