Xinyu Song

Dr. Xinyu Song

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2019 in Antimicrobial Resistance & Infection Control
Verified
Journal Article
Open access
PDF file
XSXinyu Song
Xinyu Song
LVLutz Vossebein
Lutz Vossebein
Andrea ZilleAndrea Zille
Andrea Zille
“Ready-to-use” disinfecting wipes (also known as pre-impregnated disinfecting wipe) are broadly used in food industry and domestic situations. Their application in hospitals and healthcare centres for decontamination of medical devices and surfaces is steadily increasing because of their convenient implementation in practice and reliable performance. Beside their acceptable compliance and easy application, literature reported the disinfection failure due to the interaction between textile substrate and active ingredients, which can highly increase the risk of an infection outbreak. This review aims to call attention to the wide range of variables affecting the disinfectant-impregnated wipes’ (DIWs) disinfection performances in hospitals. A systematic literature search based on the five categories i. wipes, ii. disinfectants, iii. Application methods, iv. interaction between wipes and active ingredients and v. wiping strategy which can possibly influence the disinfection effectiveness of DIWs was conducted by Google scholar. Studies regarding the efficacy evaluation of DIWs in clinical applications were also reviewed from the National Centre for Biotechnology Information database. Variables that impact on the disinfection performance of disinfectant-impregnated wipes in surface disinfection in hospitals were summarised and critically discussed. In addition to the information, current disinfectant-impregnated wipes’ decontamination efficacy test standards were reviewed, and different standards exposed some disadvantage in their testing design. Various parameters contribute to the impact of DIWs disinfection performance in practice. The interaction between disinfectant active ingredients and the wiping materials barricades their broad application in hospitals. More studies of the DIWs’ disinfection efficacy in clinical practice are in need. Current standards evaluating the DIWs’ efficacy are required to improve for more realistic condition simulation and differentiating between mechanical removal of inoculum from a surface and chemical inactivation of the test microbe.

9 December 2019 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
XSXinyu Song
Xinyu Song
Uros CvelbarUros Cvelbar
Uros Cvelbar
PSPetra Strazar
Petra Strazar
LVLutz Vossebein
Lutz Vossebein
Andrea ZilleAndrea Zille
Andrea Zille

27 October 2019 in Polymers
Verified
Journal Article
Open access
PDF file
XSXinyu Song
Xinyu Song
Uros CvelbarUros Cvelbar
Uros Cvelbar
PSPetra Strazar
Petra Strazar
LVLutz Vossebein
Lutz Vossebein
Andrea ZilleAndrea Zille
Andrea Zille
Disinfectant-impregnated wipes are broadly used in hospitals, as an important approach for infection prevention and control. But their ageing performance has rarely been studied. Untreated and Dielectric Barrier Discharge (DBD) plasma pre-treated wiping materials made of nonwoven 100% polyester (W1), nonwoven 55% cellulose/45% polyester (W2) and woven cotton (W3) were impregnated with a quaternary ammonium compound solution (ADBAC) for 30 min, 3, 7, 15, and 30 days of storage time and characterized in term of chemical, thermo-mechanical and antimicrobial efficacy. X-ray photoelectron spectroscopy analysis on the plasma-treated polyester wipes demonstrates the incorporation of reactive oxygen species on the fiber surface. Laser scanning microscopy demonstrates the plasma etching effect in smoothing the surface of the cotton wipe reducing the adsorption of ADBAC. The result showed no significant changes in breaking force and elongation during storage for W1 and W2. However, plasma treatment affects W3 in weft direction reducing the force at break in water and ADBAC treated wipes. Dynamic mechanical analysis results show that ADBAC and plasma treatment have a significant influence in W1 and W3 viscoelastic properties improving the elastic response limiting the polymeric chains mobility and the non-elastic response due to the etching effect, respectively. Overall, the plasma pre-treatment of ADBAC-impregnated wipes is able to enhance the antimicrobial performance and the storage time of polyester-containing wipes.

6 June 2022 in Textiles
Verified
Journal Article
Open access
PDF file
XSXinyu Song
Xinyu Song
PLPengyan Liu
Pengyan Liu
LYliangmin Yu
liangmin Yu
Andrea ZilleAndrea Zille
Andrea Zille
Shortage of personal protective equipment (PPE) is often projected in response to public health emergencies such as infection outbreaks and pandemics. Respiratory protective devices (RPDs), namely medical face masks and respirators, are considered the last defense for the front-line healthcare workers. Cleaning, decontamination and reuse of the disposable RPDs have been accepted by local health authorities during the pandemic period. To contribute to the mitigation of RPD shortage and ensure the safe adoption of decontamination protocols, this review discusses the regulated testing standards and the most commonly studied decontamination methods in the literature. The reuse of RPDs must fulfill three criteria: remove the microbial thread, maintain original function and structural integrity (including fitting tests) and leave no harmful residuals. Decontamination methods such as ultraviolet germicidal irradiation, moist heat and vaporized hydrogen peroxide appeared to be the most promising methods in balancing the above-mentioned criteria. However, the effectiveness of decontamination methods varies depending on the RPDs’ models, materials and design. Therefore, the adoption of protocols needs to be evidence-based with full validation in the local institutes. Additionally, new technology such as antimicrobial treated PPE that can reduce the risks of fomite during donning and doffing process with an extended lifespan should be encouraged. Overall, good training and guidance for appropriate reuse of RPDs are fundamental to ensure their efficiency in protecting front-line healthcare workers.

24 December 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
XSXinyu Song
Xinyu Song
LVL. Vossebein
L. Vossebein
Andrea ZilleAndrea Zille
Andrea Zille

27 February 2023
Verified
Book Chapter
Open access
XSXinyu Song
Xinyu Song
Jorge PadrãoJorge Padrão
Jorge Padrão
MFMarta Fernandes
Marta Fernandes
Ana RibeiroAna Ribeiro
Ana Ribeiro
LMLiliana Melro
Liliana Melro
Andrea ZilleAndrea Zille
Andrea Zille