Roel J. H. Montree

Mr. Roel J. H. Montree

Eindhoven University of Technology, Eindhoven, Noord-Brabant, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AGAlessandra Galli
Alessandra Galli
RMRoel J. H. Montree
Roel J. H. Montree
SQShuhao Que
Shuhao Que
Elisabetta PeriElisabetta Peri
Elisabetta Peri
RVRik Vullings
Rik Vullings
This work presents an overview of the main strategies that have been proposed for non-invasive monitoring of heart rate (HR) in extramural and home settings. We discuss three categories of sensing according to what physiological effect is used to measure the pulsatile activity of the heart, and we focus on an illustrative sensing modality for each of them. Therefore, electrocardiography, photoplethysmography, and mechanocardiography are presented as illustrative modalities to sense electrical activity, mechanical activity, and the peripheral effect of heart activity. In this paper, we describe the physical principles underlying the three categories and the characteristics of the different types of sensors that belong to each class, and we touch upon the most used software strategies that are currently adopted to effectively and reliably extract HR. In addition, we investigate the strengths and weaknesses of each category linked to the different applications in order to provide the reader with guidelines for selecting the most suitable solution according to the requirements and constraints of the application.

1 March 2024 in Physiological Measurement
Verified
Journal Article
Open access
RMRoel J. H. Montree
Roel J. H. Montree
Elisabetta PeriElisabetta Peri
Elisabetta Peri
RHReinder Haakma
Reinder Haakma
LDLukas R C Dekker
Lukas R C Dekker
RVRik Vullings
Rik Vullings
Objective. Wearable devices that measure vital signals using photoplethysmography are becoming more commonplace. To reduce battery consumption, computational complexity, memory footprint or transmission bandwidth, companies of commercial wearable technologies are often looking to minimize the sampling frequency of the measured vital signals. One such vital signal of interest is the pulse arrival time (PAT), which is an indicator of blood pressure. To leverage this non-invasive and non-intrusive measurement data for use in clinical decision making, the accuracy of obtained PAT-parameters needs to increase in lower sampling frequency recordings. The aim of this paper is to develop a new strategy to estimate PAT at sampling frequencies up to 25 Hertz. Approach. The method applies template matching to leverage the random nature of sampling time and expected change in the PAT. Main results. The algorithm was tested on a publicly available dataset from 22 healthy volunteers, under sitting, walking and running conditions. The method significantly reduces both the mean and the standard deviation of the error when going to lower sampling frequencies by an average of 16.6% and 20.2%, respectively. Looking only at the sitting position, this reduction is even larger, increasing to an average of 22.2% and 48.8%, respectively. Significance. This new method shows promise in allowing more accurate estimation of PAT even in lower frequency recordings.

28 August 2026 in Frontiers in Signal Processing
Verified
Journal Article
Open access
PDF file
RMRoel J. H. Montree
Roel J. H. Montree
EPElisabetta Peri
Elisabetta Peri
LDLukas R. C. Dekker
Lukas R. C. Dekker
XLXi Long
Xi Long
RHReinder Haakma
Reinder Haakma
RVRik Vullings
Rik Vullings
Introduction: Premature ventricular contractions (PVC) occur naturally in the human heart and lead to a well-studied increase in cardiac contractility, referred to as post-extrasystolic potentiation (PESP), which behaves independently of many otherwise confounding factors. It is well-known that the degree of potentiation differs between healthy and failing hearts. In this paper, we present a method for non-invasive and non-obtrusive assessment of the PESP, leveraging photoplethysmography (PPG) measurements, revealing information on the degree of potentiation and thereby cardiac functioning. Methods: We modeled the PESP as a second-order system and we compared the parameters of this system between patients with differing ejection fractions. The method was developed on an internal dataset acquired during percutaneous, electrophysiological procedures. The parameters of the proposed second-order system are determined for each of these patients and the results show a correlation between cardiac ejection fraction and the damping factor, one of the parameters of the system. Results: This model-based approach was demonstrated on the earlier mentioned non-obtrusive PPG measurements, as well as invasive blood pressure measurements. Modeling the PESP as a second-order model using information obtained from the non-invasive PPG signal reveals information showing a promising step towards enabling continuous monitoring of cardiac contractility using non-invasive means. Discussion: The presented method could be applied in non-invasive, non-obtrusive PPG recording devices such as a smartwatch. This provides a continuously monitored estimate of cardiac contractility as an additional clinical parameter, as well as decreasing the time between reduction of contractility and potential hospital admission.