Elisabetta Peri

Dr. Elisabetta Peri

Eindhoven University of Technology, Eindhoven, the Netherlands
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AGAlessandra Galli
Alessandra Galli
RMRoel J. H. Montree
Roel J. H. Montree
SQShuhao Que
Shuhao Que
Elisabetta PeriElisabetta Peri
Elisabetta Peri
RVRik Vullings
Rik Vullings
This work presents an overview of the main strategies that have been proposed for non-invasive monitoring of heart rate (HR) in extramural and home settings. We discuss three categories of sensing according to what physiological effect is used to measure the pulsatile activity of the heart, and we focus on an illustrative sensing modality for each of them. Therefore, electrocardiography, photoplethysmography, and mechanocardiography are presented as illustrative modalities to sense electrical activity, mechanical activity, and the peripheral effect of heart activity. In this paper, we describe the physical principles underlying the three categories and the characteristics of the different types of sensors that belong to each class, and we touch upon the most used software strategies that are currently adopted to effectively and reliably extract HR. In addition, we investigate the strengths and weaknesses of each category linked to the different applications in order to provide the reader with guidelines for selecting the most suitable solution according to the requirements and constraints of the application.

29 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
LXLin Xu
Lin Xu
Elisabetta PeriElisabetta Peri
Elisabetta Peri
RVRik Vullings
Rik Vullings
CRChiara Rabotti
Chiara Rabotti
Johannes Van DijkJohannes Van Dijk
Johannes Van Dijk
Massimo MischiMassimo Mischi
Massimo Mischi
Surface electromyogram (EMG) is a noninvasive measure of muscle electrical activity and has been widely used in a variety of applications. When recorded from the trunk, surface EMG can be contaminated by the cardiac electrical activity, i.e., the electrocardiogram (ECG). ECG may distort the desired EMG signal, complicating the extraction of reliable information from the trunk EMG. Several methods are available for ECG removal from the trunk EMG, but a comparative assessment of the performance of these methods is lacking, limiting the possibility of selecting a suitable method for specific applications. The aim of the present study is therefore to review and compare the performance of different ECG removal methods from the trunk EMG. To this end, a synthetic dataset was generated by combining in vivo EMG signals recorded on the biceps brachii and healthy or dysrhythmia ECG data from the Physionet database with a predefined signal-to-noise ratio. Gating, high-pass filtering, template subtraction, wavelet transform, adaptive filtering, and blind source separation were implemented for ECG removal. A robust measure of Kurtosis, i.e., KR2 and two EMG features, the average rectified value (ARV), and mean frequency (MF), were then calculated from the processed EMG signals and compared with the EMG before mixing. Our results indicate template subtraction to produce the lowest root mean square error in both ARV and MF, providing useful insight for the selection of a suitable ECG removal method.

9 August 2017 in Technology and Health Care
Verified
Journal Article
Closed access
PDF file
Elisabetta PeriElisabetta Peri
Elisabetta Peri
ATAnna Carla Turconi
Anna Carla Turconi
Emilia BiffiEmilia Biffi
Emilia Biffi
CMCristina Maghini
Cristina Maghini
DPDaniele Panzeri
Daniele Panzeri
CGChiara Gagliardi
Chiara Gagliardi
BACKGROUND: Robot-Assisted Gait Training (RAGT) is a widespread approach for locomotion rehabilitation but information about intervention frequency and duration is still lacking. OBJECTIVE: To evaluate the effect of frequency and duration of a RAGT o

13 June 2016 in European Journal of Translational Myology
Verified
Journal Article
Open access
PDF file
Elisabetta PeriElisabetta Peri
Elisabetta Peri
EAEmilia Ambrosini
Emilia Ambrosini
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
Giancarlo FerrignoGiancarlo Ferrigno
Giancarlo Ferrigno
CNClaudia Nava
Claudia Nava
SFSimona Ferrante
Simona Ferrante
Recent studies advocated the use of active cycling coupled with functional electrical stimulation to induce neuroplasticity and enhance functional improvements in stroke adult patients. The aim of this work was to evaluate whether the benefits induced by such a treatment are superior to standard physiotherapy. A single-blinded randomized controlled trial has been performed on post-acute elderly stroke patients. Patients underwent FES-augmented cycling training combined with voluntary pedaling or standard physiotherapy. The intervention consisted of fifteen 30-minutes sessions carried out within 3 weeks. Patients were evaluated before and after training, through functional scales, gait analysis and a voluntary pedaling test. Results were compared with an age-matched healthy group. Sixteen patients completed the training. After treatment, a general improvement of all clinical scales was obtained for both groups. Only the mechanical efficiency highlighted a group effect in favor of the experimental group. Although a group effect was not found for any other cycling or gait parameters, the experimental group showed a higher percentage of change with respect to the control group (e.g. the gait velocity was improved of 35.4% and 25.4% respectively, and its variation over time was higher than minimal clinical difference for the experimental group only). This trend suggests that differences in terms of motor recovery between the two groups may be achieved increasing the training dose. In conclusion, this study, although preliminary, showed that FES-augmented active cycling training seems to be effective in improving cycling and walking ability in post-acute elderly stroke patients. A higher sample size is required to confirm results.

15 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Elisabetta PeriElisabetta Peri
Elisabetta Peri
LXLin Xu
Lin Xu
CCChristian Ciccarelli
Christian Ciccarelli
NVNele L. Vandenbussche
Nele L. Vandenbussche
HXHongji Xu
Hongji Xu
Massimo MischiMassimo Mischi
Massimo Mischi
A new algorithm based on singular value decomposition (SVD) to remove cardiac contamination from trunk electromyography (EMG) is proposed. Its performance is compared to currently available algorithms at different signal-to-noise ratios (SNRs). The algorithm is applied on individual channels. An experimental calibration curve to adjust the number of SVD components to the SNR (0–20 dB) is proposed. A synthetic dataset is generated by the combination of electrocardiography (ECG) and EMG to establish a ground truth reference for validation. The performance is compared with state-of-the-art algorithms: gating, high-pass filtering, template subtraction (TS), and independent component analysis (ICA). Its applicability on real data is investigated in an illustrative diaphragm EMG of a patient with sleep apnea. The SVD-based algorithm outperforms existing methods in reconstructing trunk EMG. It is superior to the others in the time (relative mean squared error < 15%) and frequency (shift in mean frequency < 1 Hz) domains. Its feasibility is proven on diaphragm EMG, which shows a better agreement with the respiratory cycle (correlation coefficient = 0.81, p-value < 0.01) compared with TS and ICA. Its application on real data is promising to non-obtrusively estimate respiratory effort for sleep-related breathing disorders. The algorithm is not limited to the need for additional reference ECG, increasing its applicability in clinical practice.

6 October 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
AGAlessandra Galli
Alessandra Galli
Elisabetta PeriElisabetta Peri
Elisabetta Peri
CRChiara Rabotti
Chiara Rabotti
SOSotir Ouzounov
Sotir Ouzounov
Massimo MischiMassimo Mischi
Massimo Mischi
Objective. Fetal heart rate (fHR) evaluation is fundamental to guarantee timely medical intervention in case of pregnancy complications. Due to the limitations of traditional cardiotocography, multichannel electrophysiological recording was proposed as a viable alternative, which requires Blind Source Separation (BSS) techniques. Yet effective and reliable separation of the fetal ECG remains challenging due to multiple noise sources and the effects of varying fetal position. In this work, we demonstrate that the adopted electrode configuration plays a key role in the effectiveness of BSS and propose guidelines for optimal electrode positioning. Moreover, a model is proposed to automatically predict the most suited configuration for accurate BSS-based fHR estimation with a minimal number of leads, to facilitate practical implementation. Methods. We compared fHR estimation accuracy with different electrode configurations on in-silico data, identifying the optimal configuration for a recent BSS method. Based on features extracted from raw signals, we proposed a support vector regression model to automatically identify the best electrode configuration in terms of fHR estimation accuracy and to dynamically adjust it to varying fetal presentation. Evaluation was performed on real and synthetic data. Results. Guidelines for the optimal electrode configuration are proposed by using 4 leads. Prediction of configuration quality shows 80.9% accuracy; the optimal configurat- ion is recognized in 92.2% of the subjects. Conclusion. The proposed method successfully predicts the quality of the configurations, demonstrating the impact of the electrode configuration on the BSS performance. Significance. The method holds potential for long-term fetal monitoring, by dynamically choosing the optimal configuration.