Alessandra Galli

Dr. Alessandra Galli

University of Padova
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AGAlessandra Galli
Alessandra Galli
RMRoel J. H. Montree
Roel J. H. Montree
SQShuhao Que
Shuhao Que
Elisabetta PeriElisabetta Peri
Elisabetta Peri
RVRik Vullings
Rik Vullings
This work presents an overview of the main strategies that have been proposed for non-invasive monitoring of heart rate (HR) in extramural and home settings. We discuss three categories of sensing according to what physiological effect is used to measure the pulsatile activity of the heart, and we focus on an illustrative sensing modality for each of them. Therefore, electrocardiography, photoplethysmography, and mechanocardiography are presented as illustrative modalities to sense electrical activity, mechanical activity, and the peripheral effect of heart activity. In this paper, we describe the physical principles underlying the three categories and the characteristics of the different types of sensors that belong to each class, and we touch upon the most used software strategies that are currently adopted to effectively and reliably extract HR. In addition, we investigate the strengths and weaknesses of each category linked to the different applications in order to provide the reader with guidelines for selecting the most suitable solution according to the requirements and constraints of the application.

14 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Giacomo PeruzziGiacomo Peruzzi
Giacomo Peruzzi
AGAlessandra Galli
Alessandra Galli
GGGiada Giorgi
Giada Giorgi
Alessandro PozzebonAlessandro Pozzebon
Alessandro Pozzebon
Sleep posture is a key factor in assessing sleep quality, especially for individuals with Obstructive Sleep Apnea (OSA), where the sleeping position directly affects breathing patterns: the side position alleviates symptoms, while the supine position exacerbates them. Accurate detection of sleep posture is essential in assessing and improving sleep quality. Automatic sleep posture detection systems, both wearable and non-wearable, have been developed to assess sleep quality. However, wearable solutions can be intrusive and affect sleep, while non-wearable systems, such as camera-based approaches and pressure sensor arrays, often face challenges related to privacy, cost, and computational complexity. The system in this paper proposes a microcontroller-based approach exploiting the execution of an embedded machine learning (ML) model for posture classification. By locally processing data from a minimal set of pressure sensors, the system avoids the need to transmit raw data to remote units, making it lightweight and suitable for real-time applications. Our results demonstrate that this approach maintains high classification accuracy (i.e., 0.90 and 0.96 for the configurations with 6 and 15 sensors, respectively) while reducing both hardware and computational requirements.

6 October 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
AGAlessandra Galli
Alessandra Galli
Elisabetta PeriElisabetta Peri
Elisabetta Peri
CRChiara Rabotti
Chiara Rabotti
SOSotir Ouzounov
Sotir Ouzounov
Massimo MischiMassimo Mischi
Massimo Mischi
Objective. Fetal heart rate (fHR) evaluation is fundamental to guarantee timely medical intervention in case of pregnancy complications. Due to the limitations of traditional cardiotocography, multichannel electrophysiological recording was proposed as a viable alternative, which requires Blind Source Separation (BSS) techniques. Yet effective and reliable separation of the fetal ECG remains challenging due to multiple noise sources and the effects of varying fetal position. In this work, we demonstrate that the adopted electrode configuration plays a key role in the effectiveness of BSS and propose guidelines for optimal electrode positioning. Moreover, a model is proposed to automatically predict the most suited configuration for accurate BSS-based fHR estimation with a minimal number of leads, to facilitate practical implementation. Methods. We compared fHR estimation accuracy with different electrode configurations on in-silico data, identifying the optimal configuration for a recent BSS method. Based on features extracted from raw signals, we proposed a support vector regression model to automatically identify the best electrode configuration in terms of fHR estimation accuracy and to dynamically adjust it to varying fetal presentation. Evaluation was performed on real and synthetic data. Results. Guidelines for the optimal electrode configuration are proposed by using 4 leads. Prediction of configuration quality shows 80.9% accuracy; the optimal configurat- ion is recognized in 92.2% of the subjects. Conclusion. The proposed method successfully predicts the quality of the configurations, demonstrating the impact of the electrode configuration on the BSS performance. Significance. The method holds potential for long-term fetal monitoring, by dynamically choosing the optimal configuration.

15 April 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
AGAlessandra Galli
Alessandra Galli
Guglielmo FrigoGuglielmo Frigo
Guglielmo Frigo
DCDaniel Chindamo
Daniel Chindamo
ADAlessandro Depari
Alessandro Depari
MGMarco Gadola
Marco Gadola
GGGiada Giorgi
Giada Giorgi
mHealth technology, by using habitual devices, i.e., smartphones, improves prevention, diagnosis, treatment, monitoring, and management of health. Monitoring heart profile during intense sports activities allows to diagnose pathologies, not identifiable with the traditional Holter approach and, therefore, it can help preventing possible injuries. On the other hand, denoising and extracting features from electrocardiographic (ECG) signal acquired during physical activity is a challenging task due to motion artifacts and measurement noise. In this paper, we propose a solution enabling a complete analysis of ECG signal through the implementation of a robust denoising algorithm, which has been characterized on synthetic signals and then has been tested on real traces acquired with a low-cost smartphone-based device during motorbike and car races.

23 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AGAlessandra Galli
Alessandra Galli
Elisabetta PeriElisabetta Peri
Elisabetta Peri
YZYijing Zhang
Yijing Zhang
RVRik Vullings
Rik Vullings
MVMyrthe Van Der Ven
Myrthe Van Der Ven
Massimo MischiMassimo Mischi
Massimo Mischi
Multi-channel measurements from the maternal abdomen acquired by means of dry electrodes can be employed to promote long-term monitoring of fetal heart rate (fHR). The signals acquired with this type of electrode have a lower signal-to-noise ratio and different artifacts compared to signals acquired with conventional wet electrodes. Therefore, starting from the benchmark algorithm with the best performance for fHR estimation proposed by Varanini et al., we propose a new method specifically designed to remove artifacts typical of dry-electrode recordings. To test the algorithm, experimental textile electrodes were employed that produce artifacts typical of dry and capacitive electrodes. The proposed solution is based on a hybrid (hardware and software) pre-processing step designed specifically to remove the disturbing component typical of signals acquired with these electrodes (triboelectricity artifacts and amplitude modulations). The following main processing steps consist of the removal of the maternal ECG by blind source separation, the enhancement of the fetal ECG and identification of the fetal QRS complexes. Main processing is designed to be robust to the high-amplitude motion artifacts that corrupt the acquisition. The obtained denoising system was compared with the benchmark algorithm both on semi-simulated and on real data. The performance, quantified by means of sensitivity, F1-score and root-mean-square error metrics, outperforms the performance obtained with the original method available in the literature. This result proves that the design of a dedicated processing system based on the signal characteristics is necessary for reliable and accurate estimation of the fHR using dry, textile electrodes.

27 February 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
Sarah TonelloSarah Tonello
Sarah Tonello
AZAlberto Zacchini
Alberto Zacchini
AGAlessandra Galli
Alessandra Galli
Ata GolparvarAta Golparvar
Ata Golparvar
AMAli Meimandi
Ali Meimandi
CNClaudio Narduzzi
Claudio Narduzzi
Dehydration is a frequent condition in the elderly and can lead to serious health complications if not compensated timely. Early diagnosis can be problematic, as medical examinations in hospital would be needed. Fully wearable low-cost multi-sensing devices for home use could help investigate and prevent critical conditions. We introduce a sensing platform designed for operation in remote healthcare for the elderly. It combines a low-cost, highly customizable flexible inkjet-printed multi-sensor bracelet, including sensors for body impedance, skin hydration and temperature monitoring, with a small, low-power front-end circuit and an embedded unit that communicates by a Low Power Wide Area Network (LoRaWAN) transmission interface. We describe individual system components and present in-vitro experiments for their characterization. Reported results represent the fundamental proof of concept for the development of a fully operating device that can be used satisfactorily to monitor dehydration in a real-life application scenario.