Due to the high field enhancement factor and photon-absorption efficiency, carbon nanotubes (CNTs) have been widely used in optically induced field-emission as a cathode. Here, we report vertical carbon nanotube arrays (VCNTAs) that performed as high-density electron sources. A combination of high applied electric field and laser illumination made it possible to modulate the emission with laser pulses. When the bias electric field and laser power density increased, the emission process is sensitive to a power law of the laser intensity, which supports the emission mechanism of optically induced field emission followed by over-the-barrier emission. Furthermore, we determine a polarization dependence that exhibits a cosine behavior, which verifies the high possibility of optically induced field emission.
Recent discoveries in the field of nanoscale vacuum channel (NVC) structures have led to potential on-chip electron sources. However, limited research has reported on the structure or material parameters, and the superiority of a nanoscale vacuum channel in an electron source has not been adequately demonstrated. In this paper, we perform the structural optimization design of an NVC-based electron source. First, the structure parameters of a vertical NVC-based electron source are investigated. Moreover, the symmetrical NVC structure is further demonstrated to improve the emission current and effective electron efficiency. Finally, a symmetrical nano-vacuum channel structure is successfully fabricated based on simulations. The results show that the anode current exceeds 15 nA and that the effective electron efficiency exceeds 20%. Further miniaturizing the NVC structures in high integration can be utilized as an on-chip electron source, thereby, illustrating the potential in applications of electron microscopes, miniature X-ray sources and on-chip traveling wave tubes.
In this study, a cylindrical triode ultrahigh vacuum ionization gauge with a screen-printed carbon nanotube (CNT) electron source was developed, and its metrological performance in different gases was systematically investigated using an ultrahigh vacuum system. The resulting ionization gauge with a CNT cathode responded linearly to nitrogen, argon, and air pressures in the range from ~4.0 ± 1.0 × 10−7 to 6 × 10−4 Pa, which is the first reported CNT emitter-based ionization gauge whose lower limit of pressure measurement is lower than its hot cathode counterpart. In addition, the sensitivities of this novel gauge were ~0.05 Pa−1 for nitrogen, ~0.06 Pa−1 for argon, and ~0.04 Pa−1 for air, respectively. The trend of sensitivity with anode voltage, obtained by the experimental method, was roughly consistent with that gained through theoretical simulation. The advantages of the present sensor (including low power consumption for electron emissions, invisible to infrared light radiation and thermal radiation, high stability, etc.) mean that it has potential applications in space exploration.