Matteo Genitoni

Dr. Matteo Genitoni

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2024 in Advanced Electronic Materials
Verified
Journal Article
Open access
FRFederico Rondelli
Federico Rondelli
MLMichele Di Lauro
Michele Di Lauro
GSGioacchino Calandra Sebastianella
Gioacchino Calandra Sebastianella
ASAnna De Salvo
Anna De Salvo
MGMatteo Genitoni
Matteo Genitoni
FBFabio Biscarini
Fabio Biscarini
Organic Electronic platforms for biosensing are being demonstrated at a fast pace, especially in healthcare applications where the use of organic (semi‐)conductive materials leads to devices that efficiently interface living matter. Nevertheless, interesting properties of organic (semi‐)conductors are usually neglected in the development of (bio‐)sensors. Among these, the non‐linear response when operated under dynamic biasing conditions (i.e., with pulsed driving voltages), thus mimicking synaptic plasticity phenomena, offers promising and largely unexplored possibilities for bio‐sensing. The artificial synaptic response's figures of merit reflect the composition of the surrounding environment and, ultimately, the ion concentration and dynamics at the organic (semi‐)conductor/electrolyte interface. Therefore, new sensing strategies that rely on the effect of target analytes on the short‐term plasticity response of Organic Neuromorphic Devices are being demonstrated. This work presents the development of a label‐free Single Electrode Neuromorphic Device (SEND) specifically designed for in vivo real‐time mapping of dopamine concentration. The device response is investigated as a function of the driving frequency, resulting in the determination of the optimal operational configuration for minimally invasive neuromorphic devices. It exhibits stable multi‐parametric response in complex fluids, in brain's mechanical models and in vivo, enabling monitoring of local variations of dopamine concentration in the rat brain.

12 April 2024 in Neuromorphic Computing and Engineering
Verified
Journal Article
Open access
PDF file
MLMichele Di Lauro
Michele Di Lauro
FRFederico Rondelli
Federico Rondelli
ASAnna De Salvo
Anna De Salvo
ACAlessandro Corsini
Alessandro Corsini
MGMatteo Genitoni
Matteo Genitoni
FBFabio Biscarini
Fabio Biscarini
A novel organic neuromorphic device performing pattern classification is presented and demonstrated. It features an artificial soma capable of dendritic integration from three pre-synaptic neurons. The time-response of the interface between electrolytic solutions and organic mixed ionic-electronic conductors is proposed as the sole computational feature for pattern recognition, and it is easily tuned in the organic dendritic integrator by simply controlling electrolyte ionic strength. The classifier is benchmarked in speech-recognition experiments, with a sample of 14 words, encoded either from audio tracks or from kinematic data, showing excellent discrimination performances in a planar, miniaturizable, fully passive device, designed to be promptly integrated in more complex architectures where on-board pattern classification is required.

14 October 2024 in Nanotechnology
Verified
Journal Article
Open access
ALAlice Lunghi
Alice Lunghi
FVFederica Velluto
Federica Velluto
LLLuana Di Lisa
Luana Di Lisa
MGMatteo Genitoni
Matteo Genitoni
FBFabio Biscarini
Fabio Biscarini
MBMichele Bianchi
Michele Bianchi
Biomaterial-based implantable scaffolds capable of promoting physical and functional reconnection of injured spinal cord and nerves represent the latest frontier in neural tissue engineering. Here, we report the fabrication and characterization of self-standing, biocompatible and bioresorbable substrates endowed with both controlled nanotopography and electroactivity, intended for the design of transient implantable scaffolds for neural tissue engineering. In particular, we obtain conductive and nano-modulated poly(D,L-lactic acid) (PLA) and poly(lactic-co-glycolic acid) free-standing films by simply iterating a replica moulding process and coating the polymer with a thin layer of poly(3,4-ethylendioxythiophene) polystyrene sulfonate. The capability of the substrates to retain both surface patterning and electrical properties when exposed to a liquid environment has been evaluated by atomic force microscopy, electrochemical impedance spectroscopy and thermal characterizations. In particular, we show that PLA-based films maintain their surface nano-modulation for up to three weeks of exposure to a liquid environment, a time sufficient for promoting axonal anisotropic sprouting and growth during neuronal cell differentiation. In conclusion, the developed substrates represent a novel and easily-tunable platform to design bioresorbable implantable devices featuring both topographic and electrical cues.

15 August 2025 in Small Methods
Verified
Journal Article
Open access
MGMatteo Genitoni
Matteo Genitoni
PGPierpaolo Greco
Pierpaolo Greco
APAlessandro Paradisi
Alessandro Paradisi
MSMatteo Sensi
Matteo Sensi
MBMarcello Berto
Marcello Berto
FBFabio Biscarini
Fabio Biscarini
Electrolyte‐gated organic transistors (EGOTs) exponentially amplify minute polarization changes at the gate electrode into the channel current. Antibodies grafted on the EGOT gate electrode enable specific recognition of target species, yet this strategy may not be sufficient per se to resolve the target from its antagonists. Here, a label‐free EGOT immunosensor is functionalized with the antibody anti‐L‐enantiomer of Tryptophan (Trp), exhibiting sensitivity to Trp chirality. Nevertheless, the relative current change in transfer curves does not unambiguously differentiate L from D enantiomers in the concentration range 1 f m to 10 n m . To overcome this limitation, a multivariate principal component analysis (PCA) is applied on the set of renormalized parameters, extracted from the whole transfer curves according to our recent EGOT model: both L and D enantiomers are neatly separated by the sign of their principal components. Enantiomeric discrimination onset is 1 and 10 p m at 90% level of confidence and prediction, respectively, at least one order of magnitude lower than the enantiodiscrimination levels previously reported with EGOT biosensor. The same analysis performed on the best fit dose curves allows to discriminate L and D enantiomers down to the unprecedented level of detection of 100 f m .

31 May 2022 in Applied Biosciences
Verified
Journal Article
Open access
PDF file
LDLorenza Destro
Lorenza Destro
RMRoss Van Melsen
Ross Van Melsen
AGAlex Gobbi
Alex Gobbi
ATAndrea Terzi
Andrea Terzi
MGMatteo Genitoni
Matteo Genitoni
ALFONSO ZAMBONALFONSO ZAMBON
ALFONSO ZAMBON
Functionalized pyrazole-urea scaffolds are a common type II chemotype for the inhibition of protein kinases (PKs), binding simultaneously into the ATP-binding pocket with an ATP bioisostere and into a vicinal allosteric pocket with a pyrazole group. Standard approaches to the scaffold require multi-step synthesis of the ATP bioisostere followed by phosgene or triphosgene-mediated coupling with the substituted pyrazole group. Here we report an expedient approach to the chemotype, characterized by an optimized MW-assisted Suzuki coupling on easily accessed bromo-phenyl pyrazole ureas. The new protocol allowed quick access a large library of target analogues covering a broad chemical space of putative protein kinases inhibitors (PKIs).