Pierpaolo Greco

Dr. Pierpaolo Greco

Department of Neuroscience and Rehabilitation, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MSMeenu Selvaraj
Meenu Selvaraj
PGPierpaolo Greco
Pierpaolo Greco
Matteo SensiMatteo Sensi
Matteo Sensi
GSGulseren Deniz Saygin
Gulseren Deniz Saygin
NBNoemi Bellassai
Noemi Bellassai
FBFabio Biscarini
Fabio Biscarini

28 October 2008 in Chemistry of Materials
Verified
Journal Article
Closed access
Chiara DionigiChiara Dionigi
Chiara Dionigi
PGPierpaolo Greco
Pierpaolo Greco
GRGiampiero Ruani
Giampiero Ruani
MCMassimiliano Cavallini
Massimiliano Cavallini
FBFrancesco Borgatti
Francesco Borgatti
FBFabio Biscarini
Fabio Biscarini

21 January 2022 in Bioprinting
Verified
Journal Article
Closed access
STSilvia Tortorella
Silvia Tortorella
PGPierpaolo Greco
Pierpaolo Greco
FVFrancesco Valle
Francesco Valle
MBMarianna Barbalinardo
Marianna Barbalinardo
GFGiulia Foschi
Giulia Foschi
FBFabio Biscarini
Fabio Biscarini

14 January 2024 in Advanced Functional Materials
Verified
Journal Article
Open access
Matteo SensiMatteo Sensi
Matteo Sensi
Rafael Furlan De OliveiraRafael Furlan De Oliveira
Rafael Furlan De Oliveira
Marcello BertoMarcello Berto
Marcello Berto
Alessandro ParadisiAlessandro Paradisi
Alessandro Paradisi
PGPierpaolo Greco
Pierpaolo Greco
FBFabio Biscarini
Fabio Biscarini
Ambipolar electrolyte‐gated transistors (EGTs) based on reduced graphene oxide (rGO) have been demonstrated as ultra‐sensitive and highly specific immunosensors. However, the physics and chemistry ruling the device operation are still not fully unraveled. In this work, the aim is to elucidate the nature of the observed sensitivity of the device. Toward this aim, a physical–chemical model that, coupled with the experimental characterization of the rGO‐EGT, allows one to quantitatively correlate the biorecognition events at the gate electrode and the electronic properties of rGO‐EGT is proposed. The equilibrium of biorecognition occurring at the gate electrode is shown to determine the apparent charge neutrality point (CNP) of the rGO channel. The multiparametric analysis of the experimental transfer characteristics of rGO‐EGT reveals that the recognition events modulate the CNP voltage, the excess carrier density Δn, and the quantum capacitance of rGO. This analysis also explains why hole and electron carrier mobilities, interfacial capacitance, the curvature of the transfer curve, and the transconductances are insensitive to the target concentration. The understanding of the mechanisms underlying the transistor transduction of the biorecognition events is key for the interpretation of the response of the rGO‐EGT immunosensors and to guide the design of novel and more sensitive devices.

25 November 2024 in Advanced Electronic Materials
Verified
Journal Article
Open access
FRFederico Rondelli
Federico Rondelli
MLMichele Di Lauro
Michele Di Lauro
GSGioacchino Calandra Sebastianella
Gioacchino Calandra Sebastianella
ASAnna De Salvo
Anna De Salvo
MGMatteo Genitoni
Matteo Genitoni
FBFabio Biscarini
Fabio Biscarini
Organic Electronic platforms for biosensing are being demonstrated at a fast pace, especially in healthcare applications where the use of organic (semi‐)conductive materials leads to devices that efficiently interface living matter. Nevertheless, interesting properties of organic (semi‐)conductors are usually neglected in the development of (bio‐)sensors. Among these, the non‐linear response when operated under dynamic biasing conditions (i.e., with pulsed driving voltages), thus mimicking synaptic plasticity phenomena, offers promising and largely unexplored possibilities for bio‐sensing. The artificial synaptic response's figures of merit reflect the composition of the surrounding environment and, ultimately, the ion concentration and dynamics at the organic (semi‐)conductor/electrolyte interface. Therefore, new sensing strategies that rely on the effect of target analytes on the short‐term plasticity response of Organic Neuromorphic Devices are being demonstrated. This work presents the development of a label‐free Single Electrode Neuromorphic Device (SEND) specifically designed for in vivo real‐time mapping of dopamine concentration. The device response is investigated as a function of the driving frequency, resulting in the determination of the optimal operational configuration for minimally invasive neuromorphic devices. It exhibits stable multi‐parametric response in complex fluids, in brain's mechanical models and in vivo, enabling monitoring of local variations of dopamine concentration in the rat brain.

15 September 2023 in Advanced Materials Interfaces
Verified
Journal Article
Open access
ASAnna De Salvo
Anna De Salvo
FRFederico Rondelli
Federico Rondelli
MLMichele Di Lauro
Michele Di Lauro
ATAlice Tomassini
Alice Tomassini
PGPierpaolo Greco
Pierpaolo Greco
FBFabio Biscarini
Fabio Biscarini
The next generation of brain–machine interfaces are envisioned to couple signal transduction, filtering, and sorting on board with minimum power consumption and maximum bio‐integrability. These functional needs shall be mandatorily met in order to design efficient closed‐loop brain–machine interfaces aimed at treating and monitoring various disorders of the central and peripheral nervous system. Here, the pivotal role is highlighted that organic bioelectronics may have in the contextual development of all these three desiderata, by demonstrating a modular organic‐electronics circuit toward real‐time signal filtering. The inherent filtering capabilities of electrolyte‐gated organic transistor are tuned via adjustment of operational conditions and benchmarked in an electromyography experiment. Additionally, a whole‐organic signal processing circuitry is presented, coupling such transistors with ad hoc designed organic passive components. This provides the possibility to sort complex signals into their constitutive frequency components in real time, thereby delineating innovative strategies to devise organic‐based functional building‐blocks for brain–machine interfaces.