Yoshitaka Hayakawa

Dr. Yoshitaka Hayakawa

Nagaoka University of Technology, Nagaoka, Kyōto, Japan
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
YHYoshitaka Hayakawa
Yoshitaka Hayakawa
DSDaisuke Sato
Daisuke Sato
NYNoboru Yamada
Noboru Yamada
To improve the thermal design of vehicle-integrated photovoltaic (VIPV) modules, this study clarifies the characteristics of the convective heat transfer coefficient h between the vehicle roof surface and the surrounding air with respect to vehicle speed. Experiments on two types of vehicles with different body shapes indicate that h is strongly affected by vehicle speed, and it is also affected by body shape depending on the position on the roof. Empirical equations for approximating h as a function of vehicle speed and position on the vehicle roof are derived from the experimental datasets, and the differences between the equations derived herein and traditional equations that have been used for the heat transfer analysis of conventional stationary photovoltaic (PV) modules are clarified. Furthermore, the temperature change characteristics of the VIPV module were measured experimentally, confirming that h is the dominant factor causing the high temperature change rate of the VIPV module under driving conditions. In sunny summer conditions, the measured temperature change rate reaches up to 16.5 °C/min, which is approximately 10 times greater than that in the standard temperature cycle test for conventional stationary PV modules.

1 November 2021 in IEEE Journal of Photovoltaics
Verified
Journal Article
Closed access
YHYoshitaka Hayakawa
Yoshitaka Hayakawa
MBmasaaki baba
masaaki baba
NYNoboru Yamada
Noboru Yamada
Three-dimensional (3-D) curved photovoltaic (PV) modules are a potential power source for vehicles with curved surfaces. However, the irradiance on a 3-D curved PV module is nonuniform compared to a conventional flat PV module, which leads to a current mismatch and reduced power generation performance. The conventional PV modules have bypass diodes (BPD) to mitigate power degradation due to partial shadows. To address nonuniformity specific to 3-D curved PV modules, we investigated the BPD configuration. The effectiveness of the BPD configuration was simulated via optical analysis and circuit analysis with meteorological data (at Tokyo and Phoenix). For 3-D curved PV modules with a radius of curvature in the range of 1–3 m, the effectiveness of BPD becomes more pronounced when the curvature radius and diffuse fraction are smaller. In addition, among the BPD configurations examined in this simulation, remarkable power improvement was obtained when 50% of the total number of solar cells in the module was coupled with BPD. The simulation method was validated via an outdoor experiment using a prototype 3-D curved surface module.