Lotte N. S. Andreasen Struijk

Dr. Lotte N. S. Andreasen Struijk

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2006 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LSLotte N. S. Andreasen Struijk
Lotte N. S. Andreasen Struijk
This letter introduces a new inductive tongue computer interface to be used by disabled people for environmental control. The interface demands little effort from the user, provides a basis for an invisible interface, and has potential to allow a large number of commands to be facilitated

6 November 2017 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
LSLotte N. S. Andreasen Struijk
Lotte N. S. Andreasen Struijk
LELine Lindhardt Egsgaard
Line Lindhardt Egsgaard
ELEugen Romulus Lontis
Eugen Romulus Lontis
MGMichael Gaihede
Michael Gaihede
BBBo Bentsen
Bo Bentsen
For an individual with tetraplegia assistive robotic arms provide a potentially invaluable opportunity for rehabilitation. However, there is a lack of available control methods to allow these individuals to fully control the assistive arms. Here we show that it is possible for an individual with tetraplegia to use the tongue to fully control all 14 movements of an assistive robotic arm in a three dimensional space using a wireless intraoral control system, thus allowing for numerous activities of daily living. We developed a tongue-based robotic control method incorporating a multi-sensor inductive tongue interface. One abled-bodied individual and one individual with tetraplegia performed a proof of concept study by controlling the robot with their tongue using direct actuator control and endpoint control, respectively. After 30 min of training, the able-bodied experimental participant tongue controlled the assistive robot to pick up a roll of tape in 80% of the attempts. Further, the individual with tetraplegia succeeded in fully tongue controlling the assistive robot to reach for and touch a roll of tape in 100% of the attempts and to pick up the roll in 50% of the attempts. Furthermore, she controlled the robot to grasp a bottle of water and pour its contents into a cup; her first functional action in 19 years. To our knowledge, this is the first time that an individual with tetraplegia has been able to fully control an assistive robotic arm using a wireless intraoral tongue interface. The tongue interface used to control the robot is currently available for control of computers and of powered wheelchairs, and the robot employed in this study is also commercially available. Therefore, the presented results may translate into available solutions within reasonable time.

13 January 2016 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
DJDaniel Johansen
Daniel Johansen
CCChristian Cipriani
Christian Cipriani
DPDejan B. Popovic
Dejan B. Popovic
LSLotte N. S. Andreasen Struijk
Lotte N. S. Andreasen Struijk
Objective: The aim of this study was to investigate the feasibility of using an inductive tongue control system (ITCS) for controlling robotic/prosthetic hands and arms. Methods: This study presents a novel dual modal control scheme for multigrasp robotic hands combining standard electromyogram (EMG) with the ITCS. The performance of the ITCS control scheme was evaluated in a comparative study. Ten healthy subjects used both the ITCS control scheme and a conventional EMG control scheme to complete grasping exercises with the IH1 Azzurra robotic hand implementing five grasps. Time to activate a desired function or grasp was used as the performance metric. Results: Statistically significant differences were found when comparing the performance of the two control schemes. On average, the ITCS control scheme was 1.15 s faster than the EMG control scheme, corresponding to a 35.4% reduction in the activation time. The largest difference was for grasp 5 with a mean AT reduction of 45.3% (2.38 s). Conclusion: The findings indicate that using the ITCS control scheme could allow for faster activation of specific grasps or functions compared with a conventional EMG control scheme. Significance: For transhumeral and especially bilateral amputees, the ITCS control scheme could have a significant impact on the prosthesis control. In addition, the ITCS would provide bilateral amputees with the additional advantage of environmental and computer control for which the ITCS was originally developed.

1 August 2010
Verified
Conference Paper
Closed access
MLM E Lund
M E Lund
HCHenrik Vie Christiensen
Henrik Vie Christiensen
HCH A Caltenco
H A Caltenco
ELEugen Romulus Lontis
Eugen Romulus Lontis
BBBo Bentsen
Bo Bentsen
LSLotte N. S. Andreasen Struijk
Lotte N. S. Andreasen Struijk
Alternative and effective methods for controlling powered wheelchairs are important to individuals with tetraplegia and similar impairments whom are unable to use the standard joystick. This paper describes a system where tongue movements are used to control a powered wheelchair thus providing users, with high level spinal cord injuries, full control of their wheelchair. The system is based on an inductive tongue control system developed at Center for Sensory-Motor Interaction (SMI), Aalborg University. The system emulates a standard analog joystick in order to interface the wheelchair, thus ensuring that the system works with almost any wheelchair. The total embedment of the tongue interface into the mouth makes the control practically invisible. A fuzzy system combining 8 sensors for directional control allows for multidirectional control of the wheelchair. Preliminary test results show navigation abilities, which are highly competitive when compared to other tongue control system.

24 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MGMuhammad Ahsan Gull
Muhammad Ahsan Gull
MTMikkel Berg Thøgersen
Mikkel Berg Thøgersen
Stefan Hein BengtsonStefan Hein Bengtson
Stefan Hein Bengtson
MMMostafa Mohammadi
Mostafa Mohammadi
LSLotte N. S. Andreasen Struijk
Lotte N. S. Andreasen Struijk
Shaoping BaiShaoping Bai
Shaoping Bai
Wheelchair mounted upper limb exoskeletons offer an alternative way to support disabled individuals in their activities of daily living (ADL). Key challenges in exoskeleton technology include innovative mechanical design and implementation of a control method that can assure a safe and comfortable interaction between the human upper limb and exoskeleton. In this article, we present a mechanical design of a four degrees of freedom (DOF) wheelchair mounted upper limb exoskeleton. The design takes advantage of non-backdrivable mechanism that can hold the output position without energy consumption and provide assistance to the completely paralyzed users. Moreover, a PD-based trajectory tracking control is implemented to enhance the performance of human exoskeleton system for two different tasks. Preliminary results are provided to show the effectiveness and reliability of using the proposed design for physically disabled people.

4 July 2016 in Disability and Rehabilitation: Assistive Technology
Verified
Journal Article
Open access
LSLotte N. S. Andreasen Struijk
Lotte N. S. Andreasen Struijk
ELEugen R. Lontis
Eugen R. Lontis
MGMichael Gaihede
Michael Gaihede
HCHector A. Caltenco
Hector A. Caltenco
MLMorten Enemark Lund
Morten Enemark Lund
BBBo Bentsen
Bo Bentsen
Purpose: Individuals with tetraplegia depend on alternative interfaces in order to control computers and other electronic equipment. Current interfaces are often limited in the number of available control commands, and may compromise the social identity of an individual due to their undesirable appearance. The purpose of this study was to implement an alternative computer interface, which was fully embedded into the oral cavity and which provided multiple control commands. Methods: The development of a wireless, intraoral, inductive tongue computer was described. The interface encompassed a 10-key keypad area and a mouse pad area. This system was embedded wirelessly into the oral cavity of the user. The functionality of the system was demonstrated in two tetraplegic individuals and two able-bodied individuals Results: The system was invisible during use and allowed the user to type on a computer using either the keypad area or the mouse pad. The maximal typing rate was 1.8 s for repetitively typing a correct character with the keypad area and 1.4 s for repetitively typing a correct character with the mouse pad area. Conclusion: The results suggest that this inductive tongue computer interface provides an esthetically acceptable and functionally efficient environmental control for a severely disabled user.