Kseniya Vadimovna Petrova

Dr. Kseniya Vadimovna Petrova

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Russian Journal of Non-Ferrous Metals
Verified
Journal Article
Closed access
PDF file
BVBaranovskaia Borisovna Vasilisa
Baranovskaia Borisovna Vasilisa
YKYu. A. Karpov
Yu. A. Karpov
KPKseniya Vadimovna Petrova
Kseniya Vadimovna Petrova
NKNatalia Alexandrovna Korotkova
Natalia Alexandrovna Korotkova
Current trends in the application of rare-earth metals (REMs) in two major scientific and technological fields—the production of magnetic and lumines

4 August 2022 in Metals
Verified
Journal Article
Open access
PDF file
NKNatalia Alexandrovna Korotkova
Natalia Alexandrovna Korotkova
BVBaranovskaia Borisovna Vasilisa
Baranovskaia Borisovna Vasilisa
KPKseniya Vadimovna Petrova
Kseniya Vadimovna Petrova
In this article, inductively coupled plasma mass-spectrometry (ICP-MS) and inductively coupled plasma optical-emission spectrometry (ICP-OES) were used for the development of an analytical procedure for analysis of the waste of Sm-Co magnets. Experimental parameters related to microwave digestion processes and acid concentrations were optimized. Microwave digestion was carried out in mixtures of HF, HCl, HNO3 and H2SO4. The complete dissolution of the samples occurred in the system: 10 mL H2O, 2 mL HNO3, 10 mL HCl and 1 mL H2SO4. The dependence of the matrix effect on the ICP-MS analysis of waste Sm-Co magnets was studied and optimal instrumental parameters were investigated (nebulizer gas flow, sampling depth and potential at the extractor lens). The optimal conditions were a nebulizer gas flow of 0.85–0.90 L/min, a sampling depth of 101, potential at the extractor lens of −400 V and a sample flow rate of 50 rpm. A recovery test and inter-method experiments were performed to verify the accuracy of the proposed method.

14 December 2021 in Journal of Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
NKN. A. Korotkova
N. A. Korotkova
KPKseniya Vadimovna Petrova
Kseniya Vadimovna Petrova
VBV. B. Baranovskaya
V. B. Baranovskaya
Procedures are developed for the multielement analysis of high-purity cerium oxide for the manufacture of phosphors and optical materials using inductively coupled plasma–mass spectrometry (ICP–MS) and inductively coupled plasma–optical emission spectrometry (ICP–OES). The “robust” settings of the mass spectrometer are given suitable to determine Fe, Ni, Cr, Co, Cu, V, Mn, and rare-earth metals in cerium oxide (nebulizer gas flow, liquid flow, plasma sampling depth, the extract lens voltage), lowering the matrix effect and, therefore, enabling the use of more concentrated solutions for analysis. The effect of the matrix element in the direct analysis of cerium oxide by ICP–OES is estimated. The combination of mass spectral and atomic emission methods has some advantages, expands the range of elements to be determined, and increases the reliability of the analysis. In particular, the use of ICP–OES makes it possible to determine low concentrations of terbium in cerium oxide (the limit of determination for terbium by ICP–OES is 1 × 10–4 wt %) and decreases the limits of determination for Fe and Pr by a factor of 4–5 compared to ICP–MS. The limits of determination of the target components (Fe, Ni, Cr, Co, Cu, V, Mn, and rare-earth metals) in cerium oxide by ICP–MS and ICP–OES are in the range of n × 10–6– n × 10–4 wt %.

1 January 2022 in Arabian Journal of Chemistry
Verified
Journal Article
Open access
KPKseniya Vadimovna Petrova
Kseniya Vadimovna Petrova
BVBaranovskaia Borisovna Vasilisa
Baranovskaia Borisovna Vasilisa
NKNatalya A. Korotkova
Natalya A. Korotkova

18 August 2022 in Molecules
Verified
Journal Article
Open access
PDF file
AAAlexandra Alexandrovna Arkhipenko
Alexandra Alexandrovna Arkhipenko
KPKseniya Vadimovna Petrova
Kseniya Vadimovna Petrova
BVBaranovskaia Borisovna Vasilisa
Baranovskaia Borisovna Vasilisa
We developed a method of sorption determination via the atomic emission of Cu, Zr and Hf metals in the waste of samarium–cobalt magnets. This method was based on the preconcentration of impurities using S- and N-containing heterochain sorbents, with further determination of the analytes via inductively coupled plasma atomic emission spectrometry (ICP-OES). Different sorbents such as PED (polyethelendiamine), TDA (polythiodimethanamine), PhED (N-phenylpolyethediamine) and PTE (polythioether) were tested for Ti, Cu, Zr, Nb and Hf extraction. The PTE sorbent ensured the maximum extraction of the analytes (recovery 60% for Ti, 80% for Nb, 95–100% for Cu, Zr and Hf) and thus was selected for further research. Additionally, various acidities of chloride solution (0.01–1 M HCl) were investigated for metal sorption. Under the optimised sorption conditions, trace impurities of Cu, Zr and Hf were determined using ICP-OES with a relative standard deviation of less than 5%. The obtained results were confirmed by the added–found method and cross-method experiments. The detection limits (DLs) were 1.5, 2, 0.15, 2 and 0.75 µg/L for Ti, Cu, Zr, Nb and Hf, respectively. The proposed method can be successfully used for the determination of various microelements in other waste REE-magnetic materials.

22 October 2022 in Russian Journal of Non-Ferrous Metals
Verified
Journal Article
Closed access
PDF file
KPKseniya Vadimovna Petrova
Kseniya Vadimovna Petrova
VEV. V. Es’KIna
V. V. Es’KIna
VBV. B. Baranovskaya
V. B. Baranovskaya
MDM. S. Doronina
M. S. Doronina
NKN. A. Korotkova
N. A. Korotkova
AAA. A. Arkhipenko
A. A. Arkhipenko
The efficiency of using rare earth metals largely depends on their impurity composition, which affects the structure and properties of materials. Before th