Alexandra Alexandrovna Arkhipenko

Mrs. Alexandra Alexandrovna Arkhipenko

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2022 in Molecules
Verified
Journal Article
Open access
PDF file
AAAlexandra Alexandrovna Arkhipenko
Alexandra Alexandrovna Arkhipenko
KPKseniya Vadimovna Petrova
Kseniya Vadimovna Petrova
BVBaranovskaia Borisovna Vasilisa
Baranovskaia Borisovna Vasilisa
We developed a method of sorption determination via the atomic emission of Cu, Zr and Hf metals in the waste of samarium–cobalt magnets. This method was based on the preconcentration of impurities using S- and N-containing heterochain sorbents, with further determination of the analytes via inductively coupled plasma atomic emission spectrometry (ICP-OES). Different sorbents such as PED (polyethelendiamine), TDA (polythiodimethanamine), PhED (N-phenylpolyethediamine) and PTE (polythioether) were tested for Ti, Cu, Zr, Nb and Hf extraction. The PTE sorbent ensured the maximum extraction of the analytes (recovery 60% for Ti, 80% for Nb, 95–100% for Cu, Zr and Hf) and thus was selected for further research. Additionally, various acidities of chloride solution (0.01–1 M HCl) were investigated for metal sorption. Under the optimised sorption conditions, trace impurities of Cu, Zr and Hf were determined using ICP-OES with a relative standard deviation of less than 5%. The obtained results were confirmed by the added–found method and cross-method experiments. The detection limits (DLs) were 1.5, 2, 0.15, 2 and 0.75 µg/L for Ti, Cu, Zr, Nb and Hf, respectively. The proposed method can be successfully used for the determination of various microelements in other waste REE-magnetic materials.

1 August 2024 in Analytica
Verified
Journal Article
Open access
PDF file
AAAlexandra Alexandrovna Arkhipenko
Alexandra Alexandrovna Arkhipenko
GMGalina Evgenievna Marina
Galina Evgenievna Marina
MRMikhail Alexandrovich Ryumin
Mikhail Alexandrovich Ryumin
MDMarina Doronina
Marina Doronina
NKNatalia Alexandrovna Korotkova
Natalia Alexandrovna Korotkova
BVBaranovskaia Borisovna Vasilisa
Baranovskaia Borisovna Vasilisa
This work describes a two-stage technique of X-ray fluorescence (XRF) analysis of rare earth niobates. A comparison between the two approaches revealed that the Fundamental Parameters Method (FPM) can be employed for a rapid preliminary assessment of the composition of the resulting material and the construction of calibration curves can be used to determine the contents of the major elements with precision. The results of the relative standard deviation (RSD) for FPM were no more than 7%, while the approach to construct calibration curves had an RSD of no more than 1%. Calibration samples were prepared using the same synthesis method as the study samples to construct the calibration curves. The possibility of constructing calibration dependencies using mixtures of oxides was assessed, but this approach could not provide the desired accuracy. The obtained results have been shown to have a good correlation with inductively coupled plasma optical emission spectrometry. The developed technique enables the determination of the major components in niobates containing two and three rare earth elements, which are used as optical materials and medium-entropy ceramics.

30 October 2023 in Journal of Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
AAAlexandra Alexandrovna Arkhipenko
Alexandra Alexandrovna Arkhipenko
MDM. S. Doronina
M. S. Doronina
NKN. A. Korotkova
N. A. Korotkova
ASA. S. Shevchenko
A. S. Shevchenko
VBV. B. Baranovskaya
V. B. Baranovskaya
YDY. S. Dalnova
Y. S. Dalnova
A possibility of using S,N-containing sorbents for the analysis of materials based on rare earth element compounds with the determination of impurities in the sorption concentrate by arc atomic emission spectrometry is studied. The properties of S,N-containing sorbents in aqueous solutions and various rare earth matrices are studied. A methodological approach to the sorption preconcentration of impurities in REE-based materials followed by a direct analysis of the sorption concentrate by arc atomic emission spectrometry is described. The results of the development of a spectrochemical method for determining impurities in rare earth element materials are presented, and performance characteristics are evaluated.

1 November 2023 in Recycling
Verified
Journal Article
Open access
PDF file
AAAlexandra Alexandrovna Arkhipenko
Alexandra Alexandrovna Arkhipenko
GMGalina Evgenievna Marina
Galina Evgenievna Marina
MDMarina Doronina
Marina Doronina
NKNatalia Alexandrovna Korotkova
Natalia Alexandrovna Korotkova
BVBaranovskaia Borisovna Vasilisa
Baranovskaia Borisovna Vasilisa
Determination of the chemical composition of waste Sm-Co magnets is required for their efficient recycling. The non-stereotypical composition of said magnets makes an analysis extremely challenging. X-ray fluorescence spectrometry is a promising analytical tool for this task. It offers high accuracy and simplicity of sample preparation as it does not require sample dissolution. However, a serious limitation of X-ray fluorescence analysis is the spectral interference of matrix elements and impurities. In this work, a two-stage technique has been developed for the determination of the main components (Sm, Co) and impurities (Fe, Cu, Zr, Hf, Ti, Ni, Mn, Cr) in samples of spent samarium–cobalt magnets using wavelength dispersive X-ray fluorescence spectrometry. In order to overcome the main limitation of the chosen method and to maximize its capabilities of qualitative and quantitative analysis, we propose an approach to the selection of analytical lines and experimental conditions, as well as a preparation method for the calibration standards. The obtained results have been shown to have a good correlation with ICP-OES. The limits of detection are in the range of 0.001–0.02 wt%, and the limits of quantification are 0.003–0.08 wt%.

30 December 2024 in Nanosystems: Physics, Chemistry, Mathematics
Verified
Journal Article
Closed access
NKNatalia Alexandrovna Korotkova
Natalia Alexandrovna Korotkova
AAAlexandra Alexandrovna Arkhipenko
Alexandra Alexandrovna Arkhipenko
MSM.N. Smirnova
M.N. Smirnova
BVBaranovskaia Borisovna Vasilisa
Baranovskaia Borisovna Vasilisa
MDM.S. Doronina
M.S. Doronina
GMG.E. Marina
G.E. Marina

25 July 2025 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
TATimur F. Akhmetzhanov
Timur F. Akhmetzhanov
AAAlexandra Alexandrovna Arkhipenko
Alexandra Alexandrovna Arkhipenko
MRMikhail A. Ryumin
Mikhail A. Ryumin
IYIlya Yakushev
Ilya Yakushev
MDMarina S. Doronina
Marina S. Doronina
VBVasilisa B. Baranovskaya
Vasilisa B. Baranovskaya
In this paper, we discuss strategies for analysing medium- and high-entropy ceramics (REE3NbO7) that contain 4 and 5 different rare-earth elements. In the coming years, it may be necessary to shift from laboratory-based analysis of ceramic powders to on-site examination of thermal barrier coatings, particularly those employed in aircraft engines. To address this, we employed a portable X-ray fluorescence spectrometer capable of in-field non-destructive simultaneous quantification of Gd, Er, Tm, Yb and Y. The major problem with portable systems is the overlap of Gd, Er, Tm, and Yb lines. Therefore, we conducted a complete comparative study of the strategies that allow for the acquisition of analytical signals in the energy-dispersive spectra. In order to critically evaluate the need for deconvolution, a technique often suggested in the literature, we used wavelength-dispersive X-ray fluorescence. This XRF variant was used to obtain spectra with higher resolution, and thus different levels of line overlap. In this work, we highlighted peculiarities of the deconvolution process in higher- and lower-resolution X-ray fluorescence spectra. The study revealed that the portable spectrometer is capable of accurately quantifying the concentrations of Gd, Er, Tm, Yb, and Y in both medium- and high-entropy ceramics. A comparative analysis showed that quantitative analysis of medium- and high-entropy ceramics does not require deconvolution of energy-dispersive spectra. It is shown that the samples synthesised using the reverse precipitation method allow one to obtain reliable calibration curves and avoid matrix effects using a portable X-ray fluorescence spectrometer, despite the fact that the concentrations of the major components vary 3 times. However, it was found that experimental conditions in a vacuumed wavelength-dispersive X-ray fluorescence spectrometer reduced trueness by approx. 9%. Nevertheless, this system proved to be a suitable substitute for ICP-OES in laboratory practices. The portable version, on the other hand, holds promise for in-field use.