Ileana Diana Nicolae

Dr. Ileana Diana Nicolae


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
Petre-Marian NicolaePetre-Marian Nicolae
Petre-Marian Nicolae
INIleana Diana Nicolae
Ileana Diana Nicolae
MNMarian-Stefan Nicolae
Marian-Stefan Nicolae
The paper presents several theories related to definitions of powers and power factors in non-sinusoidal and non-symmetrical regimes. The theories must meet some requirements: (a) to facilitate the measuring of power quantities by using acquired electrical waveforms; (b) to support the correct quantification of powers and power factors for a fair charge; (c) to support solutions for efficient compensation of non-sinusoidal and non-symmetrical regimes, simultaneous with the power factor compensation along the fundamental harmonic. Only theories meeting the above-mentioned requirements are approached. Aspects specific to power definitions are discussed and commented. Three theories rely on the Fourier decomposition of non-sinusoidal waveforms, valid only for steady signals, whilst the fourth relies on the Discrete Wavelet Transform (DWT) and can also be applied to unsteady signals. Dedicated original data acquisition systems were used to acquire experimental data for three case studies. Data were analysed with original software tools, based on the Fast Fourier Transform and Discrete Wavelet Transform, implementing the approached theories. Comparisons between results yielded for analogue quantities proved that the approached theories satisfy the requirements for which they were created, except for the fourth theory, which can be used only for compensation purposes.

25 August 2023 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
Petre-Marian NicolaePetre-Marian Nicolae
Petre-Marian Nicolae
INIleana Diana Nicolae
Ileana Diana Nicolae
Maria Cristina NițuMaria Cristina Nițu
Maria Cristina Nițu
MNMarian-Stefan Nicolae
Marian-Stefan Nicolae
Theoretical models, numerical simulations, and experimental tests for determining surges transferred between the windings of transformers subjected to lightning impulse are addressed. Considering the surges transmitted in the transformer windings have inductive and capacitive components, the proposed model is focused on five aspects: 1) voltage transmission by electromagnetic induction; 2) surge transferred in the transformer windings by capacitive coupling; 3) oscillating component of the voltage transferred between the windings; 4) voltage transferred between the primary and secondary windings; and 5) voltage transferred to the tertiary winding. The maximum transferred voltage is analytically determined. The simulation relies on the Math Script RT Module. Experimental tests were performed on two types of transformers. For the first one (type TTUS-ONAN, 50/67 MVA, 132/13.8/6.6 kV, Ynyn0d1 connection), the maximum voltage between the medium-voltage (MV) winding and ground, in case of a 200 V impulse applied to the high-voltage winding, is around 20.3 V; the voltage transferred to the tertiary winding reaches 8.1 V. For the second type (type TTUS-ONAN, 54/73 MVA, 110/15/6.6 kV, Ynyn0d1 connection), the voltage transferred to the MV winding reaches 21.1 V; the voltage transferred to the tertiary winding is 11.9 V. The laboratory tests validate the proposed analytical and simulation model.

25 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Maria Cristina NițuMaria Cristina Nițu
Maria Cristina Nițu
INIleana Diana Nicolae
Ileana Diana Nicolae
LDLivia Andreea DINA
Livia Andreea DINA
PMPaul Mihai Mircea
Paul Mihai Mircea
Inrush current is still a persistent problem affecting the quality of the power system. This paper presents the theoretical aspects of this transient phenomenon, the simulation of the phenomenon for prediction purposes and its measurement in a test laboratory. In the operation of power transformers, there may also be cases where electrical phenomena affecting the operation of transformers may overlap. When power transformers are in operation, there may also be cases where electrical phenomena affecting their operation overlap. This paper includes a study describing such a situation, where the maximum value of the inrush current is amplified by the fact that the series resonance condition has been met. The intersection of these electrical phenomena resulted in internal and external electrical discharges that led to the overhaul of a 440 MVA transformer; the description of this situation is based on field data. The paper focuses on real information and situations that support the development of a maintenance management schedule based on accurate and up-to-date data. The information presented in this paper will be particularly useful to personnel specializing in power transformer design and/or those monitoring/operating high power transformers in the energy sector, but can also be a teaching aid for students interested in such transient phenomena.

23 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Maria Cristina NițuMaria Cristina Nițu
Maria Cristina Nițu
LDLivia Andreea DINA
Livia Andreea DINA
INIleana Diana Nicolae
Ileana Diana Nicolae
MNMarian-Stefan Nicolae
Marian-Stefan Nicolae
PMPaul Mihai Mircea
Paul Mihai Mircea
Overvoltages are brief and significant increases in the voltage level in an electrical system. They can be caused by a variety of factors, but the most common are associated with atmospheric discharges (lightning). When lightning strikes a power line, the resulting shock wave can induce surges in electrical equipment that is connected to that line, including transformers. The authors develop an analytical method in order to determine the maximum values of the overvoltages propagating in the transformer windings in case of lightning impulse. It is considered that the transmitted overvoltages consist of an inductive component (magnetic dispersion is neglected, as well as the energy exchange between the capacitances and inductances of the energized winding) and a capacitive component (between the energized winding and the receiving winding; in this case, the emphasis is on the energy exchange between the series capacitance and the inductance of the series winding). The proposed method was applied on a TTUS—ONAN/ONAF 31.5/40 MVA, 110/5/6.6 kV power transformer, and the obtained results were validated by experimental tests. The percentage error between the results obtained by modeling and the results obtained from transformer testing was less than 2%.

8 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
Petre-Marian NicolaePetre-Marian Nicolae
Petre-Marian Nicolae
INIleana Diana Nicolae
Ileana Diana Nicolae
MNMarian-Stefan Nicolae
Marian-Stefan Nicolae
The paper approaches some theories related to certain power components and power quality indices of active filtering. A brief review of the specialty literature tied to technical aspects of compensation based on active filtering is provided. Following that, the steps of a design created by the authors to perform active filtering with a shunt filter are provided. The developed filtering system was tested and experimental data were acquired on a test stand for different operational modes. The data acquired with and without filtering were compared in order to evaluate the filter efficiency. Data were analyzed and observations were made relative to the limits of one of the analyzed theories. It was concluded that another theory has to be used in order to define powers and indices for the quality of power/energy. The evaluation of compensation was made from a technical point of view, according to the standards in force for the domain of power/energy quality. It was noticed that electromagnetic interferences might occur between the active filter and the supplying network. Two indices are proposed by authors in order to provide a more accurate value for the active filtering efficiency considering the financial point of view. Examples for their utilization are provided in real cases.

25 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
INIleana Diana Nicolae
Ileana Diana Nicolae
Petre-Marian NicolaePetre-Marian Nicolae
Petre-Marian Nicolae
In this article, issues related to electromagnetic compatibility and energy/power quality for a laptop are addressed. Power quality problems are outlined. Testing frameworks (developed by authors) are presented and discussed for a laptop when two different sampling frequencies are used: 80 kHz and 19.2 kHz. Waveforms corresponding to the voltage across the laptop’s terminals and current absorbed by it were acquired. Recordings and numerical processing, based on original software using Fast Fourier Transform, are discussed, and the analysis of waveforms in both cases is performed. Various power quality indices were calculated. Theoretical and practical aspects related to the determination of power quantities, power flows, and power factor are presented. Some conclusions concerning different ranges of frequencies are presented, along with some considerations for power quality problems. Tests for conducted emissions (single phase and neutral wire respectively) and for the radiated emissions (for horizontal and vertical polarizations) are presented. Comparisons to the emission standards were made. The immunity behavior for a laptop is discussed according to immunity standards. It is shown that new measures (e.g., active filters) are necessary for network protection when connecting a laptop to the network. Some considerations, based on the authors’ observations concerning new standards for power quality and electromagnetic compatibility, are outlined.