Inrush current is still a persistent problem affecting the quality of the power system. This paper presents the theoretical aspects of this transient phenomenon, the simulation of the phenomenon for prediction purposes and its measurement in a test laboratory. In the operation of power transformers, there may also be cases where electrical phenomena affecting the operation of transformers may overlap. When power transformers are in operation, there may also be cases where electrical phenomena affecting their operation overlap. This paper includes a study describing such a situation, where the maximum value of the inrush current is amplified by the fact that the series resonance condition has been met. The intersection of these electrical phenomena resulted in internal and external electrical discharges that led to the overhaul of a 440 MVA transformer; the description of this situation is based on field data. The paper focuses on real information and situations that support the development of a maintenance management schedule based on accurate and up-to-date data. The information presented in this paper will be particularly useful to personnel specializing in power transformer design and/or those monitoring/operating high power transformers in the energy sector, but can also be a teaching aid for students interested in such transient phenomena.
Overvoltages are brief and significant increases in the voltage level in an electrical system. They can be caused by a variety of factors, but the most common are associated with atmospheric discharges (lightning). When lightning strikes a power line, the resulting shock wave can induce surges in electrical equipment that is connected to that line, including transformers. The authors develop an analytical method in order to determine the maximum values of the overvoltages propagating in the transformer windings in case of lightning impulse. It is considered that the transmitted overvoltages consist of an inductive component (magnetic dispersion is neglected, as well as the energy exchange between the capacitances and inductances of the energized winding) and a capacitive component (between the energized winding and the receiving winding; in this case, the emphasis is on the energy exchange between the series capacitance and the inductance of the series winding). The proposed method was applied on a TTUS—ONAN/ONAF 31.5/40 MVA, 110/5/6.6 kV power transformer, and the obtained results were validated by experimental tests. The percentage error between the results obtained by modeling and the results obtained from transformer testing was less than 2%.
This paper presents a method of testing some connection elements used in the construction of OHL - overhead power lines. The testing of the clamps during thermal cycles was carried out in accordance with the provisions of the SR EN 61284:2000 standard, corresponding to IEC 61284:1997, and the results obtained after the testing are presented. It can be seen that this type of test provides the beneficiaries with essential information regarding the state of the equipment, and allows the estimation of an optimal duration of the equipment's operation.
The actual operation of the power distribution systems asks for high standards concerning the performance of the system in terms of continuity and safety in supplying consumers on the one hand and the quality of the delivered energy on the other hand. Thus, the paper aims to present a complete analysis of the impact that the modification of the neutral treatment system in a 110 kV / MV station belonging to Energy Distribution Oltenia (DEO), has on both the number and the type of unwanted events or phenomena as well as on the network parameters and the transient regime which occurs as a result of some defects with the earth. All of these have been analyzed taking into account the new performance standards that distribution systems have to respect.
This study presents issues related to electromagnetic pollution and the level of magnetic field radiation occurring around conductors used for electricity transmission and distribution. The fact that modeling and simulation are the most efficient methods of optimization, considering the cost–benefit ratio, was the premise of this work. This paper proposes the performance of a complex analysis, carried out in a comparative manner, which includes physical tests and simulations in the existing field around transmission and distribution cables used in transformer substations. In the first stage, the level of the magnetic field existing near the conductor carried by an electric current was tested (measured), and a virtual model was then designed to simulate the field in conditions similar to those of the test. The results obtained from the simulation were analyzed in comparison with those obtained by testing. The maximum permissible limits of exposure to an electromagnetic field, which are regulated by Government Decision HG 520/2016 of 20 July 2016 and Directive 2013/35/EU of the European Parliament and of the Council of 26 June 2013, were used as the reference to formulate conclusions for both situations considered. These comparisons were intended to determine the level of exposure to electromagnetic fields existing in places where electricity transmission/distribution conductors are located. Energy sustainability exists due to the versatile properties of the conductors, with the energy transmission and distribution network being functional regardless of the source of energy production.