Hao Liu

Dr. Hao Liu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2022 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
XWXing-Jin Wang
Xing-Jin Wang
KHKang-Kang Huang
Kang-Kang Huang
JHJun-Bo He
Jun-Bo He
TWTing-Kui Wu
Ting-Kui Wu
XRXin Rong
Xin Rong
HLHao Liu
Hao Liu
Purpose: To investigate the relationship between the preoperative paraspinal Goutalier grade of fatty infiltration and postoperative cervical sagittal alignment in patients undergoing anterior cervical discectomy and fusion (ACDF). Methods: A total of 101 patients who underwent single-level ACDF with the Zero-profile implant system between March 2011 and April 2020 were included in this study. Cervical sagittal alignment parameters, including the C2-C7 Cobb angle, functional spinal unit (FSU) angle, cervical sagittal vertical axis (SVA), and T1 slope (T1S), were assessed. Preoperative magnetic resonance images were used to classify patients according to Goutalier grade. Clinical outcomes including Neck Disability Index (NDI) scores, Japanese Orthepaedic Association (JOA) scores and Visual Analogue Scale (VAS) scores were collected and analyzed. Results: According to the Goutalier grade, 33 patients were classified as Goutalier 0–1 (Group A), 44 were classified as Goutalier 1.5–2 (Group B), and 24 were classified as Goutalier 2.5–4.0 (Group C). The mean age among the three groups showed significant differences (P = 0.007). At the last follow-up, the C2-C7 Cobb angle, FSU angle, and T1S improved after the surgery among the groups. Although there were varying degrees of loss of curvature among the different groups during the follow-up period, the postoperative cervical sagittal alignment parameters demonstrated no statistical differences among the three groups (P > 0.05). In addition, patients in all groups experienced significant relief of their symptoms, and the clinical scores were comparable among the groups (P > 0.05). Conclusion: The complex nature of anterior cervical surgery requires surgical attention both in decompression and sagittal alignment. Our study demonstrates satisfactory postoperative cervical sagittal alignment of patients despite different grades of fatty infiltration of the multifidus muscle following single-level ACDF. Based on our results, the improvement and maintenance of cervical sagittal alignment after ACDF remains a complex problem that spine surgeons should consider before surgery.

2 January 2021 in Dysphagia
Verified
Journal Article
Closed access
PDF file
CHChengyi Huang
Chengyi Huang
HAHaimiti Abudouaini
Haimiti Abudouaini
BWBeiyu Wang
Beiyu Wang
CDChen Ding
Chen Ding
YMYang Meng
Yang Meng
HLHao Liu
Hao Liu

6 October 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
CHCheng-Yi Huang
Cheng-Yi Huang
YMYang Meng
Yang Meng
BWBeiyu Wang
Beiyu Wang
JYJie Yu
Jie Yu
CDChen Ding
Chen Ding
HLHao Liu
Hao Liu
Objectives: To investigate the effect of the difference in C2–7 angle on dysphagia after anterior cervical discectomy and fusion (ACDF) with the Zero-P Implant System. Methods: A retrospective analysis of 181 patients who underwent ACDF with the Zero-P Implant System and had at least one year of follow-up from January 2011 to November 2018 was performed. All patients were divided into a non-dysphagia group and a dysphagia group to explore the effect of the difference between postoperative and preoperative C2–7 angle (dC2–7A) on postoperative dysphagia. At the same time, other possible related factors including the difference between postoperative and preoperative O-C2 angle (dO-C2A), sex, age, body mass index (BMI), intraoperative time, estimated blood loss, diabetes mellitus, hypertension, smoking, alcohol consumption, prevertebral soft-tissue swelling (PSTS), the highest segment involved in the surgery and the levels of surgery segments were analyzed. Results: In total, the non-dysphagia group comprised 139 patients and the dysphagia group comprised 42 patients. The single-factor analysis showed that smoking, PSTS and dC2–7A were significantly different between the two groups (P < 0.05). Spearman’s correlation coefficient showed no significant correlation between the degree of dysphagia and dC2–7A (P > 0.05). The results of the multiple-factor analysis with an ordinal logistic regression model showed that smoking, PSTS and dC2–7A were significantly associated with the incidence of dysphagia (P < 0.05). Conclusions: The postoperative C2–7 angle has an important effect on the occurrence of dysphagia in patients undergoing Zero-P implant system interbody fusion surgery.

17 December 2024 in Orthopaedic Surgery
Verified
Journal Article
Open access
XWXing‐Jin Wang
Xing‐Jin Wang
JHJun‐Bo He
Jun‐Bo He
TWTing‐Kui Wu
Ting‐Kui Wu
BWBeiyu Wang
Beiyu Wang
XRXin Rong
Xin Rong
HLHao Liu
Hao Liu
Objectives: Anterior cervical discectomy and fusion (ACDF) has been widely used in the treatment of cervical degenerative disc disease (CDDD). Previous studies have demonstrated that the size of implants in ACDF determines radiological and clinical outcomes. However, the principles of choosing an appropriate implant size in ACDF remain controversial. The study aimed to elucidate the influence of the cage size of Zero‐profile implant system and offer proposals on the selection of implant size during ACDF.Methods: This retrospective study analyzed 109 patients who underwent single‐level ACDF from March 2011 to April 2020 with the Zero‐profile implant system. The patients were categorized into two groups based on the preoperative mean height of adjacent segments (Hm). Clinical outcomes included the Japanese Orthopaedic Association scores (JOA), Neck Disability Index (NDI) and visual analog scale (VAS). In addition, radiographical analysis encompassed cervical lordosis (CL), functional spinal unit (FSU) angle, range of motion (ROM) of the total cervical spine and the FSU, anterior and posterior FSU height, C1–C7 sagittal vertical axis (SVA), C2–C7 SVA, the center of gravity of the head (CGH)‐C7 SVA as well as T1 slope (T1S) measurements. Besides, bone fusion rates, anterior bone loss, subsidence, and adjacent segment degeneration were also recorded.Results: Overall, 37 patients in Group A had an implant size ≥ Hm while 72 patients in Group B had an implant size < Hm. The preoperative general data and radiological parameters were comparable between the groups. At the last follow‐up, both groups had satisfactory clinical outcomes. As for radiological outcomes, the anterior and posterior FSU heights were significantly higher in Group A compared to Group B (p < 0.05) after ACDF. Besides, both groups corrected and maintained the CL and FSU. However, the average C1–C7 SVA and C2–C7 SVA at the last follow‐up were significantly higher in the Group B than in the Group A (C1–C7 SVA: 27.42 ± 9.23 mm vs. 31.76 ± 10.68 mm, p = 0.038; C2–C7 SVA: 14.65 ± 7.27 mm vs. 19.64 ± 8.68, p = 0.003). Additionally, the fusion rates were significantly higher in Group A at the first two follow‐up visits.Conclusion: Our study showed that an appropriate size of Zero‐profile implant system is crucial to achieving favorable clinical and radiological outcomes after performing ACDF. Implants with a larger height but not oversize could maintain the cervical sagittal balance and FSU height and achieve early bone fusion. Therefore, a larger height might be a better choice for achieving a satisfactory long‐term prognosis if Zero‐profile implants of adjacent size both fit the disc space properly.

6 August 2024 in Orthopaedic Surgery
Verified
Journal Article
Open access
CHCheng‐Yi Huang
Cheng‐Yi Huang
XSXia‐Qing Sheng
Xia‐Qing Sheng
TWTing‐Kui Wu
Ting‐Kui Wu
BWBeiyu Wang
Beiyu Wang
DWDing‐Ke Wen
Ding‐Ke Wen
HLHao Liu
Hao Liu
Objective: When implanting the Zero‐P device, the screws of Zero‐P form a bone wedge with a 40 ± 5° cranial and caudal angle (CCA). However, no study has been performed in the optimal CCA of the Zero‐P implant. To investigate whether the cranial/caudal angles (CCA) of the screws affect the clinical and radiological outcomes in patients undergoing ACDF with the Zero‐P implant.Methods: From January 2016 to December 2023, we retrospectively analyzed 186 patients who underwent 1‐level ACDF with the Zero‐P device. The patients were divided into four groups: group A (cranial angle ≤40°, caudal angle ≤40°); group B (cranial angle ≤40°, caudal angle >40°); group C (cranial angle >40°, caudal angle ≤40°); and group D (cranial angle >40°, caudal angle >40°). The clinical outcomes, including Japanese Orthopaedic Association (JOA), neck disability index (NDI), and visual analogue scale (VAS) scores, the radiological parameters, including cervical lordosis (CL), cervical lordosis of operated segments (OPCL), intervertebral space height (ISH) and fusion rate (FR), and the complications, were evaluated and compared. Parametric tests, non‐parametric tests, and chi‐square tests were conducted to analyze the data.Results: The OPCL of group A was significantly less than that of the other groups at the final follow‐up (p < 0.05). The ISH of group D was significantly less than that of group A at the final follow‐up (p < 0.05). The subsidence rate of group A was significantly less than that of group D at the final follow‐up (p < 0.05). At the final follow‐up, the upper adjacent‐level degeneration (ASD) of group D was significantly less severe than that of groups A and B (p < 0.05). The clinical outcomes do not differ among groups (p > 0.05).Conclusion: A larger CCA of the screws (cranial angle >40°, caudal angle >40°) was better for maintaining OPCL and reducing the incidence of ASD. A smaller CCA of the screws (cranial angle ≤40°, caudal angle ≤40°) was better for maintaining ISH and reducing the rate of subsidence.

23 February 2025 in Orthopaedic Surgery
Verified
Journal Article
Open access
CHCheng‐Yi Huang
Cheng‐Yi Huang
JHJun‐Bo He
Jun‐Bo He
XWXing‐Jin Wang
Xing‐Jin Wang
TWTing‐Kui Wu
Ting‐Kui Wu
BWBeiyu Wang
Beiyu Wang
HLHao Liu
Hao Liu
Objective: The principle of selecting a Zero‐P implant of an appropriate height remains a topic of debate, particularly when similarly sized implants seem to appropriately fit the intervertebral space. Thus, this study compared the biomechanical performance of smaller and larger Zero‐P implants within an appropriate height range with that of oversized Zero‐P implants for anterior cervical discectomy and fusion (ACDF).Methods: A three‐dimensional finite element (FE) model of the C2–C7 cervical spine was constructed and validated. The implants were categorized as smaller (6 mm), larger (7 mm), and oversized (8 mm) according to the average intervertebral height and implant specifications. Thus, the following four FE models were constructed: the intact cervical spine model (M1), the 6 mm model (M2), the 7 mm model (M3), and the 8 mm (M4) Zero‐P implant C5/6 segment ACDF surgical model. Then, a pure moment of 1.0 N·m combined with a follower load of 75 N was applied at C2 to simulate flexion, extension, lateral bending, and axial rotation.Results: The results indicated that the maximum stress on the vertebral body, intervertebral disc, and facet joints under self‐weight increased with increasing Zero‐P height. Under six different loading conditions, the maximum stress on the vertebral body in the surgical segment of the M4 model was generally greater than that in the M2 and M3 models. Following an increase in the height of the implant from 6 mm to 8 mm, the maximum stress increased, and the intervertebral disc stress of both segments reached its peak in the M4 model. In the M4 model, the implant experienced the highest stress, whereas the M2 model exhibited the lowest stress on the implant under both self‐weight and loading conditions. Furthermore, the stress on the posterior facet joints of the surgical segment increased with increasing Zero‐P height. The range of maximum stress on the posterior facet joints for the M3 model was situated between that of the M2 and M4 models.Conclusion: In summary, after determining the appropriate height range for the implant in accordance with the mean height of the intervertebral space, opting for a larger size appears to be more advantageous. This approach helps maintain the height of the intervertebral space and provides greater stress, promoting a tighter fit between the upper and lower endplates and the Zero‐P. This tighter fit is crucial for maintaining spinal stability, enhancing the early bony fusion rate, and potentially leading to better postoperative outcomes.